Early in the design process room layout and usage may not yet be known.  Analysis can still be performed, however, by assigning more general data to the entire building on the Building tab of Set Model Properties.
 
Simply by defining usage, constructions, an HVAC System and the location of the entire building it is possible to start using VE-Ware and the VE-Toolkits to get early Energy, Carbon and Daylighting assessments and compare different architectural design options.
 
 
 

Building Type

 
Define the primary use of the building from the list which includes Office, Hotel and University/School amongst others.  This is used to apply thermal template data including Heating and Cooling Set Points, Internal Gains and Infiltration rates.
 

Building Constructions

 
Apply constructions from the IESVE Constructions Database to surfaces and openings in the building.
 
Click the Constructions button to open the Building Construction dialog.
 
 
The only Construction Type available to edit here is for the whole building.  Simply choose a construction for each surface and opening type in the model from the extensive lists. These constructions will then be applied to each occurrence of that surface in the building.
 
Note: Construction data in the form of Revit Architecture or Revit MEP is not passed directly from the model.
 

Building Service

 
This is used to select an HVAC System for the entire building.
 
Building System
Mechanism
Active Chilled Beam
Heating and cooling
Central Heating Convectors
Heating only
Central Heating Hot Air
Heating only
Central Heating Radiant Floors
Heating only
Central Heating Radiators
Heating only
Constant Volume Dual Duct
Heating and cooling
Constant Volume Fixed O A
Heating and cooling
Constant Volume Terminal Reheat
Heating and cooling
Constant Volume Variable O A
Heating and cooling
Fan Coil System
Heating and cooling
Multizone Hot Deck Cold Deck
Heating and cooling
Other Room Heater
Heating only
Radiant Cooled Ceilings
Cooling only
Radiant Heater Flued
Heating only
Radiant Heater Multiburner
Heating only
Radiant Heater No Flued
Heating only
Split Systems With Mechanical Ventilation
Heating only
Split Systems With Mechanical Ventilation With Cooling
Heating and cooling
Split Systems With Natural Ventilation
Heating only
V A V Dual Duct
Heating and cooling
V A V Indoor Packaged Cabinet
Heating and cooling
V A V Single Duct
Heating and cooling
Variable Refrigerant Flow
Heating and cooling
Water Loop Heat Pump
Heating and cooling
 
 

Place and Location