×
Menu
Index

4.20.1 Attributes

Available processing profile
Available processing profile allows selection of a profile from the database to define the availability of the Tidal power object due to manual operation.  If a schedule is not required, the profile should be defined as “on continuously”.
 
Tidal stream speed profile
The Tidal stream speed profile defines the speed of the water experienced by the Tidal power object.
 
Energy feedback
The Energy feedback option allows the user to determine whether the electricity generated by the Tidal power object can be fed back to the power grid.  If the box is checked (the condition is true), the Tidal power object always generates the maximum amount of electrical energy it can and will feed back power to the grid if output exceeds demand.  If the box is unchecked (the condition is false), the Tidal power object will only supply power in order to meet demand.
 
Power curve
A Power curve defines the performance curve of the Tidal power object as a function of water speed.  Power value (along the y-axis) should be entered as a proportion of the Rated power (on a scale from 0 to 1).  All curves must pass through the origin, that is, have zero power output at zero water speed. A Curve Editor is accessed by double clicking on the Power curve input value, then selecting the edit button that appears in the field.
 
Rated power
Rated power is the maximum power that the Tidal power object can produce.