9.2.6. iCIM project-level scenarios creation

If the iCD model is part of a larger centralised iCIM/iRoadmap project (multi-model iCIM projects) it is possible to create a scenario of the full iCIM project from the iCD. This functionality creates a duplicate of the entire iCIM project the iCD model is synchronised to as a new scenario. The scenario can then be synchronised later back in each iCD model being part of the iCIM project for editing.
This functionality is essential in order to create a scenario for an iCIM project that is an aggregation of multiple iCD models.
To create a scenario of the full iCIM project:
-          Click the Synchronisation button to open the iCIM Synchronisation dialog;
-          Click the + Create Scenario on iCIM (see Figure 9-42);
Figure 9-42 Create Scenario in iCIM
 
Note: this button will only appear in models that are already synchronised to an iCIM project.
 
-          In the Scenario Name dialog that iCD prompts, enter the name of the new scenario and click Create scenario (see Figure 9-43).
Figure 9-43 Scenario Name dialog
-          Once the scenario is created in iCIM, iCD shows the newly created scenario in the synchronisation dialog. As this scenario has only been created in iCIM, it appears “Not synched” and is greyed out by default (see Figure 9-44).
Figure 9-44 Newly created iCIM scenario visible from the synchronisation dialog
-          To retrieve the scenario for further editing in iCD, turn the Toggle button on, select “create in iCD” (see Figure 9-45) and click Start synch.
Figure 9-45 Importing newly created scenario 3 to iCD
-          Once downloaded, the new scenario will be available as scenario in iCD (and located in the same folder as the baseline SketchUp model). To open it in iCD, select it from the scenario dialog as shown in Figure 9-46 (see more on that in chapter 7) or open the .skp file with SketchUp.
Figure 9-46 New Scenario created in iCIM and downloaded in iCD available from the Scenario dialog
 
 