4.15.1. Evolution of the 3D model over time
In order for the 3D model to reflect the evolution of a project (addition or demolition of iCD object: buildings, roads, trees, etc…) the user needs to set the attributes “Date constructed” and Date demolished” for each object.
If not already visible, these attributes can be made visible in the “Attribute Visibility” settings in the IES iCD extension (Figure 4-87, see chapter 3.2.5 Attribute Visibility Setting).
Figure 4-98 Attribute Visibility window
For each building, the year of construction and demolition can be entered using the Room/Building query tool (See Figure 4-89 below).
Figure 4-99 Date Demolished and Date Constructed attributes in the room/building query tool
Once done, it possible to visualise the evolution of the project by changing the current year of the model via Extensions -> IES iCD -> Time.
In the Time window, it is first possible to set the colours and the respective opacities of Demolished Entities and Not Constructed entities for visualization. (See Figure 4-90 below)
Figure 4-100 The time window in iCD
Finally, the current year can be set by either moving the cursor along the year bar or directly typing the year in the Current year dialog box and click ‘Apply’ to validate.
While setting the current year a visual gives an overview of the construction status over the model.
Buildings can thus appear in 3 colours depending on their status:
1. Currently existing buildings will appear normal with glazing and roof
2. Not constructed buildings will appear in orange (colours as set here)
3. Demolished buildings will appear in navy blue (colours as set here)
Figure 4-101 Model in 1984, the buildings in orange are yet to be constructed
Figure 4-102 Model in 2000, two buildings were constructed since 1984
Figure 4-103 Model in 2020, more buildings were constructed since 2000 and two building were demolished (in blue)
Figure 4-104 Model in 2051, all the buildings are constructed and some additional building were demolished
Auto Apply
If the Auto apply box is ticked, iCD will directly update the visual (with not constructed and demolished objects) as soon as the year is changed. If the Auto apply box is not ticked then a button Apply appears in the bottom left part of the dialog. This button allows the end-user to manually apply changes after having set the current year and visualise the changes over the model (see Figure 4-95).
Figure 4-105: Time dialog with the Auto apply off (left) and on (right)
Once the Save and close button is clicked, this closes the time window and set the selected year as current. The Demolished or Not constructed buildings for this year will then disappear from the model.
They are now located in different layers and can be made visible/invisible using the IES iCD layers (For more details on layers, see 4.1.1 ICD Layers) .
Render geometry changes
Ticking the Render geometry changes will adjust the building geometry with the year in addition to showing not constructed and demolished buildings. It will for example, directly show on the model the addition or removal of floors.
In the example below, a second floor was added to the building in the front in 2022.
With the Render geometry changes, switching from 2021 to 2022, directly reflects this additional floor (see Figure 4-96).
Figure 4-106: ticking Render geometry changes allows to visualise the geometry evolution of a building
Note: the default current year of an iCD model corresponds to the year the model was first created.