Part L2 (2013/2014) VE-SBEM Results

 
This tab on the dialog at the lower edge of the VE Compliance screen allows you to view the results of Part L2 (2013/2014) calculations.
 
Building Emissions Rate (BER)
The Building Emissions Rate (kgCO 2 /m2) calculated for the actual building.
 
Notional Building Emissions Rate
The Building Emissions Rate (kgCO 2 /m2) calculated for the notional building (C notional ).
 
Target Emissions Rate (TER)
The 2013/2014 Target Emission Rate is the 2013/2014 Notional  building emission rate.
 
Did the analysis pass the CO2 emissions rating?
The pass/fail result for Criterion 1. ‘YES’ if BER<TER, ‘NO’ otherwise.
 
View Compliance Doc
Click on this button to view the Compliance Document generated by BRUKL using inputs from the actual and notional building simulations, together with the data entered in Building & System Data and the results of the Criterion 2 U-value checks and Criterion 3 Solar Gain checks
 
Calculation details
Click on this button to view the calculation data using inputs from the SBEM calculations, together with the data entered in Building & System Data and the results of the Criterion 2 U-value checks.
 
Extra output files
Two further output files are copied to the project’s Regs\Part L2\SBEM\BRUKL folder and may be of interest. Both are in comma-separated format.
·       <buildingname>_not_sim.csv      The calculation details for the Notional building
·       <buildingname>_dr.csv                The data reflection report for the Actual building