delivery_efficiency
|
(float) DHW delivery efficiency if simple mode, None otherwise
|
|
dhw_design_supply_temperature_set_point_profile
|
(string) DHW design supply temperature set point profile ID if simple mode and setpoint type is profile, None otherwise
|
|
dhw_design_supply_temperature_set_point_type
|
|
|
dhw_design_supply_temperature_set_point_value
|
(float) DHW design supply temperature set point value if simple mode and setpoint type is constant, None otherwise
|
|
dhw_location_on_hwl
|
|
|
hwl_dhw_heat_exchanger
|
|
|
hx_approach
|
(float) Heat exchanger approach if explicit mode, None otherwise
|
|
hx_effectiveness
|
(float) Heat exchanger effectiveness
|
|
hx_load_hwl_hx_capacity
|
(float, W) Heat exchanger load and HWL HX capacity if explicit mode, None otherwise
|
|
hx_source_side_flow_rate
|
(float) Heat exchanger source-side flow rate if explicit mode, None otherwise
|
|
hx_supply_flow_rate
|
(float) Heat exchanger DHW supply flow rate if explicit mode, None otherwise
|
|
is_pre_heat_using_solar_water_heater
|
(bool) Is DHW pre-heat using Solar Water Heater (SWH)? True or False if simple mode, None otherwise.
|
|
is_pump_used
|
(bool) Is a DHW pump used? True or False if explicit mode, None otherwise.
|
|
is_recirculation_percent_of_flow
|
(bool) Is this recirculation a percentage of the DHW design supply flow? True or False if recirculation is used, None otherwise.
|
|
is_recirculation_scheduled
|
(bool) Is the recirculation scheduled? True or False if recirculation is used, None otherwise.
|
|
is_recirculation_used
|
(bool) Is DHW recirculation used? True if so, False otherwise
|
|
is_storage_tank_used
|
(bool) Is a DHW storage tank used? True if so, False otherwise
|
|
pump
|
(HVACPump) Pump component if a DHW pump is used, None otherwise
|
|
pump_heat_gain_fraction
|
(float) Pump heat gain (fraction) if a DHW pump is used, None otherwise
|
|
recirculation_flow_rate
|
(float) Recirculation flow rate if recirculation is used, None otherwise
|
|
recirculation_loop_length
|
(float) Recirculation loop length if recirculation is used, None otherwise
|
|
recirculation_losses
|
(float) Recirculation losses if recirculation is used, None otherwise
|
|
recirculation_percent_of_supply_flow_rate
|
(float) % of DHW design supply flow rate if recirculation is used, None otherwise
|
|
recirculation_profile_id
|
(string) Recirculation profile ID if recirculation is used, None otherwise
|
|
recirculation_pump_meter
|
(VEEnergyMeter) Recirculation pump meter ID if recirculation is used, None otherwise
|
|
recirculation_pump_power
|
(float) Recirculation pump power if recirculation is used, None otherwise
|
|
recirculation_schedule_type
|
|
|
solar_water_heater
|
|
|
specific_pump_power_at_rated_speed
|
(float) Specific pump power at rated speed if a DHW pump is used, None otherwise
|
|
tank_heat_loss
|
(float) Storage tank heat loss if storage tank is used, None otherwise
|
|
tank_insulation_thickness
|
(float) Tank insulation thickness if storage tank is used, None otherwise
|
|
tank_insulation_type
|
|
|
tank_storage_volume
|
(float) Tank storage volume if storage tank is used, None otherwise
|
|
tank_type
|
|