Ashrae621Version
|
ashrae621_2004, ashrae621_2007, ashrae621_2010, ashrae621_2013
|
CoilLocationCircuit
|
primary, secondary
|
CoolingCoilModelType
|
simple_cooling_coil, advanced_cooling_coil
|
DehumidificationControlOption
|
per_system_level_dry_bulb_or_dew_point_control_only, system_supply_air_conditioned_per_zone_relative_humidity_sensors
|
DesignZoneTemperatureSource
|
design_zone_air_temperature, temperature_setpoint
|
ExhaustMakeUpAirOption
|
make_up_air_is_hundred_percent_primary_air, make_up_air_is_hundred_percent_transfer_air, transfer_air_makes_up_difference, make_up_air_includes_fixed_percentage_transfer_air
|
GarageFanControlScheme
|
on_occupied, on_occupied_plus_extension, on_continously, reduce_airflow_unoccupied, modulate_airflow
|
HeatingCoilModelType
|
simple_heating_coil, advanced_heating_coil
|
HeatingSourceSystemType
|
heating_system_generic, heating_system_hot_water_loop, heating_system_aa_heat_pump, heating_system_wa_heat_pump, heating_system_heat_transfer_loop, heating_system_electric, heating_system_vrf
|
HumidificationControlOption
|
per_system_level_relative_humidity_control_only, system_supply_air_humidified_per_zone_relative_humidity_sensors
|
HVACACCCalculationStatus
|
autocalc_ready, autocalc_complete, notposs_contactfactor, notposs_error1, notposs_error2, notposs_error3, notposs_error4, notposs_error5, notposs_error6, notposs_error7, autocalc_warning8, autocalc_notposs_error9, autocalc_notposs_error_unknown, mancalc_ready, mancalc_complete, mancalc_notposs_error1, mancalc_notposs_error2, mancalc_notposs_error3, mancalc_notposs_error4, mancalc_notposs_error5, mancalc_notposs_error6, mancalc_notposs_error7, mancalc_notposs_error8, mancalc_notposs_error9, mancalc_notposs_error10, mancalc_notposs_error_unknown
|
HVACACCSizingMode
|
autosizing, manual, both
|
HVACBoilerType
|
hot_water_boiler, part_load_curve_boiler
|
HVACChillerType
|
CoolingChiller, DischargeChiller, ElectricAirCooled, ElectricWaterCooled, PartLoadCurve
|
HVACCoolingSourceSystemType
|
legacy, chilled_water_loop, unitary_cooling, waterside_economizer, direct_expansion, water_air_heat_pump, generic_cooling_source, variable_refrigerant_flow
|
HVACDefrostControl
|
on_demand, timed
|
HVACDefrostStrategy
|
resistive, reverse_cycle
|
HVACDHWModel
|
explicit, simple
|
HVACDHWTankDetails
|
insulation_details, heat_loss
|
HVACDHWTankInsulationType
|
uninsulated, loose_jacket, factory_insulated
|
HVACDHWTemperatureSetPointType
|
constant, profile
|
HVACDryFluidCoolerMode
|
dual_mode, dry_mode
|
HVACDXCoolingCondenserType
|
air_cooled, evaporative_cooled, number_of_types
|
HVACDXFanControl
|
one_speed_fan, two_speed_fan, vsd_fan
|
HVACHeatPumpType
|
air_source_heat_pump, air_water_heat_pump, air_air_heat_pump
|
HVACHeatRecoveryModel
|
basic, percentage_hr, explicit
|
HVACLocation
|
duct_ext_to_building, duct_contained_within_room, duct_contained_within_void, duct_contained_within_ra_plenum, duct_contained_within_sa_plenum, duct_contained_within_zone
|
HVACMultiplexLayerEditingMode
|
current, all_selected
|
HVACNetworkObjectType
|
not_set, generic, component, controller, multiplex, prototype_system, waterside_container
|
HVACOutdoorUnitControl
|
load_priority, load_priority_with_compressor_power, zone_priority, master_thermostat_priority, thermostat_offeset_priority, profile
|
HVACPrototypeSystemType
|
prm_system_1, prm_system_2, prm_system_3, prm_system_4, prm_system_5, prm_system_6, prm_system_7, prm_system_8, prm_system_9, prm_system_10, actimass_system, tata_renew_sc_system, cool_phase_system
|
HVACRecirculationScheduleType
|
space_occupancy, time_switch_profile
|
HVACSHWPanelType
|
flat_panel, parabolic_panel
|
HVACSysClassification
|
no_classification, standard_design_system, t24_design_system, t24_standard_design_system, ncm_design_system, prm_2004_compliance_system, prm_2007_compliance_system, prm_2010_compliance_system, prm_2013_compliance_system, prm_2016_compliance_system, ecb_2010_compliance_system, ecb_2013_compliance_system, necb_2011_compliance_system, iecc_2012_compliance_system
|
HVACSystemCurveRole
|
CHILL_FCAPTT, CHILL_FEIRTT, CHILL_FEIRPT, PUMP_PWRV, BOIL_FEPT, EAC_FCAPTT, EAC_FEIRTT, EAC_FEIRPT, DX_FCAPTT, DX_FEIRTT, DX_FEIRP, WAHP_FCAPTT_HEAT, WAHP_FEIRTT_HEAT, WAHP_FEIRP_HEAT, WAHP_FCAPTT_COOL, WAHP_FEIRTT_COOL, WAHP_FEIRP_COOL
|
HVACSystemCurveType
|
centrifugal, reciprocating, screw, screw, other
|
HVACSystemLink
|
ACT_BEAM_IU_INDUCED_AIRFLOW, ACT_BM_IU_PRIMARY_AIR_CAV_VAV_COOL, ACT_BM_IU_PRIMARY_AIR_CAV_VAV_HEAT, ADJACENT_SPACE_WITH_EA_FAN, AHU_COOLING_COIL, AHU_HEATING_COIL, AHU_PRE_HEAT_COIL, AIRFLOW_ON_IF_NV_INSUF_COOL, AIRFLOW_ON_IF_NV_INSUF_VENT, CAV_AIRFLOW_NIGHTTIME_SETBACK, CAV_AIRFLOW_OCCUPIED_HOURS, COOLING_AIRFLOW_VAV_CAV, COOLING_COIL_AHU_COOL_LAT, COOLING_COIL_AHU_DEHUM_LAT, COOLING_COIL_AHU_EXTEND_DEHUM_LAT, COOLING_COIL_AHU_LOWTEMP_LAT, COOLING_COIL_AHU_SUPPLY_AIR_DPT, COOLING_COIL_COIL_LEAVING_DPT, COOLING_COIL_DOAS_DEHUM, COOLING_COIL_DOAS_FIXED_TEMP, COOLING_COIL_DOAS_TEMPERING, COOLING_COIL_FULL_COOLING_LAT_BAND, COOLING_COIL_FULL_DEHUM_LAT_BAND, COOLING_COIL_FULL_H_C_DEHUM_LAT, COOLING_COIL_FULL_H_C_LAT_BAND, COOLING_COIL_ZONE_FIXED_LAT, COOLING_COIL_ZONE_VARIABLE_LAT, COOLING_COIL_ZONE_VARIABLE_LAT_NO_OFFSET, COOLING_ONLY_SYS_AIRFLOW, COOLING_THERMOSTAT, DEDICATED_OA_VENT_COOLING_COIL, DEDICATED_OA_VENT_HEATING_COIL, DELIMITER, DIRECT_ACTING_HEATER_COOLER, DIRECT_EVAP_COOLING, DIRECT_EVAP_SPRAY, DOAS_AHU_COOLING_DEVICE, DOAS_PTAC_PTHP_COOLING_AIRFLOW_CAV_2SP_VAV, DOAS_PTAC_PTHP_HEATING_AIRFLOW_CAV_2SP_VAV, DOAS_VENT_AIRFLOW, DOAS_VENT_AIRFLOW_CAV_DCV, DUAL_FAN_DUAL_DUCT_ZN_HEAT_AIRFLOW, EA_PERCENT_AVAILABLE_TO_ER, EA_PERCENT_VS_RETURN_OR_TRANSFER, ELEC_HEAT_COIL_2ND_STAGE, ENERGY_RECOVERY_BYPASS_DAMPER, ENERGY_RECOVERY_BYPASS_LEGACY_DAMPER, ENERGY_RECOVERY_HX_WHEEL, ER_BYPASS_TEMP_TARGET, ER_BYPASS_TEMP_TARGET_LEGACY_CONFIG, ER_BYPASS_TEMP_TARGET_PSZ, ER_BYPASS_TEMP_TARGET_PSZ_LEGACY, ER_TARGET_COOL_MODE, ER_TARGET_HEAT_MODE, ER_TARGET_PSZ_HEAT_COOL, EVAP_SPRAY_HUMID_PER_ZN_RH, EVAP_SPRAY_HUMID_SA_RH, EXHAUST_CV_HOOD_AIRFLOW, EXHAUST_DRIVEN_VENTILATION_AIRFLOW, EXHAUST_FAN, FCU_ACT_BEAM_COOL_COIL, FCU_ACT_BEAM_HEAT_COIL, FCU_COOLING_AIRFLOW_CAV_2SP_VAV, FCU_FAN, FCU_HEATING_AIRFLOW_CAV_2SP_VAV, FILTER_PRESSURE_AND_CHANGE, FPB_FAN, FPB_PRIMARY_AIRFLOW_CAV_VAV, FPB_SECONDARY_AIRFLOW_CAV_2SP_VAV, HEATED_COOLED_SLAB_ZONE, HEATING_AIRFLOW_VAV_CAV, HEATING_COIL_AHU_MIN_SAT, HEATING_COIL_DOAS_TEMPERING, HEATING_COIL_FULL_HEATING_LAT_BAND, HEATING_COIL_FULL_H_C_LAT_BAND, HEATING_COIL_MIN_SAT_WITH_RESET, HEATING_COIL_ZN_FIX_LAT_STAGE_1, HEATING_COIL_ZN_FIX_LAT_STAGE_2, HEATING_COIL_ZONE_FIXED_LAT, HEATING_COIL_ZONE_VARIABLE_LAT, HEATING_COIL_ZONE_VARIABLE_LAT_NO_OFFSET, HEATING_ONLY_SYS_AIRFLOW, HEATING_THERMOSTAT, HEAT_PIPE_RR_WHL_BYPASS_DAMPER, HEAT_PIPE_RUN_RND_WHEEL, HP_RRCOIL_WHL_BYPASS_TEMP, HP_RR_WHL_BYPASS_TEMP_DIFF, INDIRECT_EVAP_COOLING, INDIRECT_EVAP_SPRAY, MIN_FAN_AIRFLOW, MIXED_MODE_DISABLE, MIXED_MODE_TOUT_TZN_DELTA, MODULATION_BY_LOAD, NONE, OA_ECON_DIFF_ENTHALPY, OA_ECON_DPT_LIMIT, OA_ECON_TARGET_AND_DBT_LIMIT, OA_ECON_TARGET_PER_RA_TEMP, OA_ECON_TARGET_RESET, OA_ECON_ZN_TEMP_LOW_LIMIT, OA_FIXED_PERCENTAGE, OA_MIN_RESET_OCCUPIED_ZONE_CO2, OA_MIN_RESET_OCCUPIED_ZONE_VAV_FLOW_PERCENT, OA_MIN_RESET_UNOCCUPIED_ZN, OA_MIN_RESET_UNOCCUPIED_ZN_VAV_FLOW_PERCENT, OA_MIN_RESET_ZN_VAV_FLOW_PERCENT, OA_MIN_RESET_ZONE_CO2, OA_VARIABLE_MIN_PERCENTAGE, OCCUPIED_ZONE, OUTSIDE_AIR_FIXED_MIN_DAMPER, OUTSIDE_AIR_MIN_ECON_DAMPER, OUTSIDE_AIR_NO_MIN_ECON_DAMPER, OUTSIDE_AIR_VARIABLE_MIN_DAMPER, PACKAGE_TERMINAL_UNIT_FAN, PARKING_GARAGE_EXHAUST, PRE_HEAT_COIL_AHU_MIN_EAT, PSZ_COOLING_AIRFLOW_CAV_2SP_VAV, PSZ_HEATING_AIRFLOW_CAV_2SP_VAV, PTAC_PTHP_COOLING_COIL, PTAC_PTHP_COOL_AIRFLOW_CAV_2SP_VAV, PTAC_PTHP_COOL_AIRFLOW_CAV_2SP_VAV_NO_OFFSET, PTAC_PTHP_HEATING_COIL, PTAC_PTHP_HEAT_AIRFLOW_CAV_2SP_VAV, PTAC_PTHP_HEAT_AIRFLOW_CAV_2SP_VAV_NO_OFFSET, RAD_CONV_COOL_DEVICE_PANEL, RAD_CONV_HEAT_DEVICE_PANEL, RA_BYPASS_MIXED_AIR_TARGET_TEMP, RA_DUCT_HEAT_LOSS_GAIN, RA_PERCENT_TO_ALT_PATH_OR_ZONE, RA_PLENUM, RETURN_AIR_DAMPER, RETURN_RELIEF_FAN, SA_DUCT_HEAT_LOSS_GAIN, SA_UFAD_PLENUM, SERIES_FPB_DAMPER, STEAM_HUMIDIFIER, STEAM_HUMID_PER_ZN_RH, STEAM_HUMID_SA_RH, STRATIFIED_ZN_REMIX_AIRFLOW, SUPPLY_FAN, SUPPLY_FAN_TSP_ADDITION, THERMALLY_STRATIFIED_ZONE, UCS_COOLING_AIRFLOW, UCS_COOLING_COIL, UNIT_HEATER_FAN, VOID_SPACE, ZONE_AIRFLOW_DETECTION, ZONE_COOLING_DEVICE, ZONE_DCV_STAGE1_VAV_CTRL, ZONE_MIXING_BOX_DAMPER, ZONE_MIXING_FIXED_DBT_DAMPER_TARGET, ZONE_MIXING_PERCENT_PRIMARY_AIR, ZONE_MIXING_VARIABLE_DBT_TARGET, ZONE_RA_TRANSFER_AIRFLOW, ZONE_REHEAT_HEATING_COIL, ZONE_RH_HIGH_LIMIT_FOR_DEC
|
HVACWaterWaterHeatExchangerDataType
|
cooling, heating
|
OccupantDiversity
|
room_data_diversity_factors, specify_independently, ashrae621_time_averaging
|
OutdoorAirRequirementLinkage
|
linked, maximum, sum
|
ProfileVariation
|
constant, profile, two_values, relative_to_zone_room
|
SpaceOutdoorAirRequirementBasis
|
ashrae_621, outdoor_requirement, ashrae_170, maximum, sum, title_24
|
StrategyOutsideAirVentilationMinReq
|
occupied_opening_hours_only, occupied_extension_hours, all_hours
|
StrategySystemFanOperation
|
on_continously, cycling, off_continously, any_strategy
|
SystemOutdoorAirRequirementBasis
|
ashrae_621, sum_of_zone_outdoor_air_requirements
|
SystemSizingBypassOption
|
bypass_system_sizing, system_sizing_on
|
TemperatureSetPointType
|
constant_value, profile
|
TerminalUnitFanControl
|
constant_fan_control, two_speed_fan_control, variable_fan_control
|
UnitType
|
no_conversion, distance_km, distance_m, distance_cm, distance_mm, volume_flow_rate_m3_per_person, volume_flow_rate_litres_per_person, temperature, heatflux_wm2, heatflux_w, coordinates, area_m2, volume_m3, heating_cooling_power_kw, heating_cooling_power_per_person, heating_cooling_power_per_person_short, volume_flow_rate_litres_per_person_m2, layer_thick, volume_litres, speed_metres_per_second, mass_kg, temperature_difference_positive, temperature_difference_positive_negative, energy_joules, humidity_ratio, pressure, volume_flow, mass_flow, enthalpy, density, specific_heat_capacity, conductivity, heat_transfer_coefficient, conductance, resistance, electrical_power_area, heating_cooling_power_kw, heating_cooling_power_w, heating_cooling_power_person, heating_cooling_power_area, solar_flux, occupancy_density, volume_flow_area, condensation_rate, condensation, lumens, lux_lumens_m2, viscosity, luminous_intensity, luminance, enthalpy_kj, crack_flow, pressure_in_mercury, pressure_in_water, vapour_permeability, vapour_permeance, luminous_power_density, luminous_efficacy_watt, length_m_to_in, volume_flow_rate_m3_per_person_cfm, cost_area, formatting_only, heating_cooling_power_w_display_kw, specific_fan_power, dhw_consumption_hour_per_person_uk, dhw_consumption_hour_per_person_us, heatflux_watts, thermal_capacity_kjm2k, tank_loss, line_loss, second_order_heat_loss, volume_flow_rate_litres_per_hour_m2, temperature_coefficient, volume_litres_uk_gallons, volume_flow_rate_litres_per_hour_gallon, circulation_loss, storage_loss_us_gallon, volume_litres_per_us_gallons, hourly_volumetric_flow, parts_per_million, inverse_length, pressure_velocity_1, pressure_velocity_2, pressure_velocity_3, mass_flow_per_hour, energy_consumption_per_hour, flow_litres_per_second_gpm, flow_per_km, watts_per_flow, inverse_k, inverse_k2, enthalpy_difference, volume_m3_us_gallon, linear_heat_transfer_coefficient, flow_gpm_kbtu_per_hour, inverse_k3, sbem_heat_transfer_rate, flow_per_person, dhw_consumption_per_hour_us, electrical_power_length, volume_flow_rate_litres_per_second_m2_facade, kwh_m2_to_kbtu_ft2, inverse_area_m2, inverse_per_energy_consumption_kwh, length_m_display_mm, mass_tonne_short_ton, wind_speed, volume_flow_ach, occupancy_people, degrees, percent, volume_flow_air_changes_per_hour_short, land_area, land_density, mass_kg_per_m, volume_flow_m3_per_hour_per_m2_of_envelope, pressure_inches_of_water_column, condensation_rate_kg_m2_second, joules_ton_hours, gigajoules_ton_hours, gigajoules_ton_kwh, occupany_people_per_100_m2, volume_flow_per_unit, volume_flow_equals_supply_air, volume_flow_greater_than_supply_air, volume_flow_percentage_above_supply_air, heating_cooling_power_kw_area, area_heating_cooling_power, suspended_solid, area_cm2, temperature_half_ip, constant_fan_control, two_speed_fan_control, variable_fan_control, no_conversion, distance_km, distance_m, distance_cm, distance_mm, volume_flow_rate_m3_per_person, volume_flow_rate_litres_per_person, temperature, heatflux_wm2, heatflux_w, coordinates, area_m2, volume_m3, heating_cooling_power_kw, heating_cooling_power_per_person, heating_cooling_power_per_person_short, volume_flow_rate_litres_per_person_m2, layer_thick, volume_litres, speed_metres_per_second, mass_kg, temperature_difference_positive, temperature_difference_positive_negative, energy_joules, humidity_ratio, pressure, volume_flow, mass_flow, enthalpy, density, specific_heat_capacity, conductivity, heat_transfer_coefficient, conductance, resistance, electrical_power_area, heating_cooling_power_kw, heating_cooling_power_w, heating_cooling_power_person, heating_cooling_power_area, solar_flux, occupancy_density, volume_flow_area, condensation_rate, condensation, lumens, lux_lumens_m2, viscosity, luminous_intensity, luminance, enthalpy_kj, crack_flow, pressure_in_mercury, pressure_in_water, vapour_permeability, vapour_permeance, luminous_power_density, luminous_efficacy_watt, length_m_to_in, volume_flow_rate_m3_per_person_cfm, cost_area, formatting_only, heating_cooling_power_w_display_kw, specific_fan_power, dhw_consumption_hour_per_person_uk, dhw_consumption_hour_per_person_us, heatflux_watts, thermal_capacity_kjm2k, tank_loss, line_loss, second_order_heat_loss, volume_flow_rate_litres_per_hour_m2, temperature_coefficient, volume_litres_uk_gallons, volume_flow_rate_litres_per_hour_gallon, circulation_loss, storage_loss_us_gallon, volume_litres_per_us_gallons, hourly_volumetric_flow, parts_per_million, inverse_length, pressure_velocity_1, pressure_velocity_2, pressure_velocity_3, mass_flow_per_hour, energy_consumption_per_hour, flow_litres_per_second_gpm, flow_per_km, watts_per_flow, inverse_k, inverse_k2, enthalpy_difference, volume_m3_us_gallon, linear_heat_transfer_coefficient, flow_gpm_kbtu_per_hour, inverse_k3, sbem_heat_transfer_rate, flow_per_person, dhw_consumption_per_hour_us, electrical_power_length, volume_flow_rate_litres_per_second_m2_facade, kwh_m2_to_kbtu_ft2, inverse_area_m2, inverse_per_energy_consumption_kwh, length_m_display_mm, mass_tonne_short_ton, wind_speed, volume_flow_ach, occupancy_people, degrees, percent, volume_flow_air_changes_per_hour_short, land_area, land_density, mass_kg_per_m, volume_flow_m3_per_hour_per_m2_of_envelope, pressure_inches_of_water_column, condensation_rate_kg_m2_second, joules_ton_hours, gigajoules_ton_hours, gigajoules_ton_kwh, occupany_people_per_100_m2, volume_flow_per_unit, volume_flow_equals_supply_air, volume_flow_greater_than_supply_air, volume_flow_percentage_above_supply_air, heating_cooling_power_kw_area, area_heating_cooling_power, suspended_solid, area_cm2, temperature_half_ip
|