Overview

 
Profiles describe the time variation of thermal input parameters. They are used in ApacheCalc, ApacheSim, ApacheHVAC, MacroFlo, Part L/J and Template Manager. Examples of their use include scheduling plant equipment, modulating casual gains and ventilation rates, specifying the timing and degree of window opening and defining time-varying set-points and supply temperatures.
 
Profiles are of two types:
·       Modulating profiles are used to modulate inputs such as gains, ventilation rates and window opening, and to schedule plant. They take the form of a time series of values in the range 0 - 1.
·       Absolute profiles are used to specify the time variation of variables such as set-points and supply temperatures. They take the form of a time series of a physical variable (most commonly temperature).
 
Both modulating and absolute profiles can be defined as functions of weather or simulation variables. They are then known as formula profiles.
 
A profile specifies time variation over a year. It is assembled from daily profiles describing the pattern of variation over a day. Daily profiles are built into weekly profiles to establish a repeating pattern over the weeks of the year. Optionally, different weekly patterns can be used for different date ranges by defining annual profiles.
APpro may be accessed by clicking on the APpro icon found in many applications.
Its purpose is to allow you to define a set of profiles for use in the project. APpro provides facilities for creating, viewing, editing and copying profiles, aided by access to central ‘system’ databases of profiles. In the Template Manager, profiles may be transferred from one project to another attached to gains and air exchanges.
 

Units

 
Certain types of profile, namely absolute profiles and formula profiles, are sensitive to the choice of Units System (metric or IP). These profiles have an attribute indicating the Units System to be used when interpreting their values, together with any variables input to formulae, at run-time.
The profile’s Units System can be different from the Units System currently set for the project.
The Units System for the project may be changed using the <VE> menu option Settings > Preferences > Units, and this setting will be assigned by default to newly created profiles of the types identified above. However, the Units Type for a profile can be edited independently of the Units Type for the Project, so it is possible (for example) for temperature profiles defined in degrees Fahrenheit and degrees Celsius to coexist in the same project.