9.2.1. iCIM / iRoadmap Endpoint setting
Buildings’ data in iCD can be synchronized to an iCIM project or an iRoadmap project. This allows end users to have access within the iCIM to the full array of data used or generated in iCD. In iRoadmap, this allows user to re-use an iCD model as an iRoadmap baseline model.
In order to let the iCD know which iCIM or iRoadmap deployment to synchronize with, the endpoint of the deployment the user has access to needs to be mapped in the iCD.
To create and manage endpoints, click the Synchronise button in the iCD Toolbar
to open the iCIM Synchronisation window click the Manage button (see below). It opens the Manage Locations / Endpoint window.
Figure 9-22: Manage Locations / Endpoint window
Note: if the model is already synchronised, clicking the synchronise button does not give access to the open the Manage Locations / Endpoint anymore. Alternatively, it is possible to open the Manage Locations / Endpoint window through the IES iCD extension.
To do so, the enable dangerous operations should be first activated. It can be accessed via Extension Tab > IES iCD > IES iCIM client > advanced > enable dangerous operations as shown below.
Once enabled, the manage endpoint tool can be access via Extension Tab > IES iCD > IES iCIM client > advanced > Manage Endpoints. This opens the Manage Locations / Endpoint window.
Figure 9-23 IES iCD - iCIM location
In the Manage Locations / Endpoint window, the location tab lists the different endpoints already available.
To manually add a single iCIM or iRoadmap endpoint, click on the +Add New Tab.
Figure 9-24 – iCIM New Endpoint window
This opens the manage endpoint window shown above which allows end users to add, save, import or export lists of iCIM or iRoadmap endpoints.
By clicking the Add button, new endpoints can be added in the add endpoint window. The end user is then asked to enter a description of the endpoint and its URL.
Note: The URL in the image below is only an example.
The URL should then be checked by clicking the Check URL button. Once checked, add the endpoint by clicking the + Create button. The endpoint is then added to the list. Click on Save to validate the updated list of available endpoints.
In the example below, an Endpoint named New endpoint Test was added. Once added and checked, the endpoint appears in the list and is available to add projects to it.
Figure 9-25 iCIM Endpoint – Adding an Endpoint
Note: It is possible to add new endpoints listed in a .Json file by clicking the Import button in the Locations Tab.
Now that the endpoint is defined in iCD and checked, it can be used to synchronise the iCD model to iCIM or iRoadmap. Back in the iCIM Synchronisation dialog, the endpoint created can be selected from the dropdown list as shown below. As the user selects the endpoint, he is redirected to the IES login webpage. Here the user will need to enter their IES credential. If the user doesn’t have a user name and password, click on the signup now and create a user login. Once this is done the user will be able to create a project in iCIM or iRoadmap and also automatically export the iCD model to it (see Figure 9-26 below).
Figure 9-26 iCIM Endpoint – Selecting an endpoint
Once the endpoint selected, it is possible to either connect the iCD model to a pre-existing iCIM or iRoadmap project from the Project tab or create a new one in the + Add New tab.