7.1. Scenarios generation methodology
Steps involved in Scenarios generation and comparison:
Scenario generation involves the creation of a base case. When using the Scenario tool, the current opened model is considered to be the base case. Before generating scenarios, run a simulation on the current model.
In the example below, a base case model was designed and simulated in iCD with the following characteristics:
|
Constructions
|
Base case Energy
|
|
External Wall
|
Brick-Block wall (U=0.44 W/m2.K)
|
|
External Window
|
6 mm Pilkington Single Glazing (U=5.56W/m2.K, SHGC=0.82)
|
|
Fittings and Fixtures
|
Base case
|
|
Toilet (Dual Flush) (l/use)
|
6
|
|
Urinals (l/use)
|
3.8
|
1. Click the Scenario icon in the iCD toolbar to open the Scenario window (See Figure 7-1). The upper part of this windows shows the current file’s name which is called <base> (see Figure 7-2).
Figure 7-2: Scenario dialog
2. To create a new scenario, click the “Duplicate” button. An editable field appears to name the new scenario. Type the desired name and click “Confirm”.
In this example, a new scenario called “Scenario 1” is created (See Figure 7-3).
Figure 7-3 Creating a new scenario called "Scenario 1"
3. Creating a new scenario creates a replica of the baseline’s skp file in the same folder.
For example, if the iCD baseline model is called “test glasgow.skp”. The new scenario file’s name is then named “test glasgow^Scenario 1.skp”.
The new scenario created is the exact copy of the base. The next step is to edit Scenario 1 to reflect the differences with the baseline.
Note: all the created Scenarios should be located in the same folder.
4. To edit the new scenario, click on the Folder icon on the right part of Scenario 1 (See Figure 7-4). Clicking the folder icon closes the current file (test glasgow.skp in the example) and opens the new file (test glasgow^Scenario 1.skp).
Figure 7-4 How to edit the Scenario "Scenario 1"
Note: The baseline can’t be deleted nor renamed.
This opens the new scenario’s file as shown in Figure 7-5. Scenario 1 is now the current file and now carries the mention “<editing>”. The baseline is still available for further editing by clicking on its folder icon (Figure 7-5).
Figure 7-5 The "Scenario 1" is the current file and ready to be edited before simulating it
5. When this new file created is open for editing, all the necessary modifications can be made: improving the envelope and/or water fittings and/or HVAC type etc…
In this example, characteristics of Scenario 1 were improved as shown in the table below:
|
Constructions
|
Proposed case 01 Energy
|
|
External Wall
|
Standard wall construction (Insulated to 1995 UK regulations) (U=0.40 W/m2.K)
|
|
External Window
|
Low-E Double Glazing SC=0.6 (U=2.01W/m2.K, SHGC=0.51)
|
|
Fittings and Fixtures
|
Proposed case 01
|
|
Toilet (Dual Flush) (l/use)
|
4
|
|
Urinals (l/use)
|
1
|
6. Once the modifications done, run the energy/ water simulation. For more information on how to launch an energy simulation see chapter 5.4 iCD Simulation Launcher.
Note: the new file created can be independently opened and edited as well.
Similarly, more files can be created with different optimization results for comparison. Simulation results for each new scenario are independently stored in their respective .skp files.
Once all the required scenarios have been simulated, their results can be compared.
7. To compare the different scenarios results, go back to the scenario tab.
8. Tick the box for each of the different scenarios to be included in the comparative analysis and click Compare Scenarios (see Figure 7-6).
Figure 7-6 Compare scenarios
9. The list of available scenarios appears in the window (see Figure 7-7). Select the report to compare the different scenarios over and click View reports.
Figure 7-7: Scenario reports
10. This will generate a report for all the selected scenarios and enable the user to compare the results over all of them.
In the example below, the energy results in the Full Energy reports were compared over two different scenarios: baseline and Scenario 1 (see Figure 7-6).
Here in the Figure 7-8 below is the comparison of the Monthly energy consumptions between both scenarios.
Figure 7-8: Monthly Site Energy Consumption compared over two different scenarios
Choosing a water report, we can compare the water consumptions as well (See Figure 7-9).
Figure 7-9 Site's water consumption compared over two different scenarios