In iCD, it is possible to complete an energy simulation with a basic carbon emission analysis.
The carbon analysis will allow the user to get some understanding the total site’s carbon emissions.
If photovoltaic panels and trees are present in the models, the carbon analysis can also assess their total CO2 they offset (through CO2 free electricity generation and carbon sequestration).
Carbon analysis results can be visualised in the Annual Carbon Emission report. This report is accessible in Extension > IES iCD > Reports > Site Renewable Reports > Annual Carbon Emission.
This report consists in a pie chart showing annual carbon emission (electrical and non-electrical) as well as PVs and trees emission offsets (see Figure 5-25).
For more information on the Annual Carbon Emission report, see chapter 6.2.6.4 Annual Carbon emissions.
Figure 5-27 Annual Carbon Emission report
In order for this report to give relevant results, the following steps are necessary:
- Set the Carbon emission coefficients;
- Set the Fuel type for heating and hot water for the buildings;
- Set the PV and tree layout if any;
- Perform an energy/water simulation.
Once these steps are complete, the user can visualise the carbon analysis in the Annual Carbon Emission report.
Carbon Emission Coefficients
Carbon emission coefficient can be accessed in Extension > IES iCD > Preferences under the section Carbon emission coefficient.
The carbon emission coefficient for all the commodities used in the project can be set in this section (see Figure 5-26).
Note: these coefficients are expressed in kg CO2 per kWh.
For more detail on how to set carbon emission coefficient in the preferences panel see chapter 3.3.2 Carbon Coefficient Emission.
Figure 5-28 Carbon Emission Coefficients settings
Setting the fuel type
To set the fuel type for building the user should select the building and open the Building/room query tool (see chapter 4.9.1 QUERY TOOL). Under the section HVAC Services, can be set the appropriate Fuel type (heating & Hot water) can be selected amongst the list of available commodities.
Note: For any commodity selected in Fuel Type, it is important to set its carbon emission coefficient in the preferences panel.
Creating Photovoltaic Panels (PV) and trees
PVs and trees will be considered for the site’s carbon emission they manage to offset by generating CO2-free electricity (PV) and sequestrating carbon (trees). For more information on PV panels and trees creation and settings, see chapter 4.10 Photovoltaic (PV) panels and 4.11 Trees.
Energy/water simulation
In order to visualise carbon emissions, an energy/water simulation should first be run in order to assess the site’s energy consumption.
For more information on energy/water simulations, see chapter 5.4 iCD Simulation Launcher.
Annual Carbon Emissions
Site’s carbon emissions can be visualised in the Annual Carbon Emission report. For more detail about this report, see chapter 6.2.6.4 Annual Carbon emissions.