5.5. Socio-Economic Indicators and Custom calculations
The Socioeconomic Indicators dialogue allows the end-user to perform a series of calculations, over a number of years, based on specific inputs. The user can use these calculations to generate values for the default socioeconomic indicators, or create their own custom indicators and calculations.
Custom calculations (or Socio-Economic Indicators) are done at a boundary level. It is then necessary to have defined boundaries in the model prior to doing these calculations. For more information on Boundaries see chapter 4.14 Boundaries.
There are two ways to access the Socio-Economic indicators Dialog:
1. You can right-click on the desired boundary, select IES iCD > Socio-economic Indicators.
2. Or Open the Boundary tool in the tool bar. Select the desired boundary from the list by ticking the box on its left side. Then click Boundaries > Socio-economic indicators (see Figure 5-17).
Figure 5-19: Access to the Socio-economic indicator dialog from the Boundary tool
Start Year and Number of years to simulate
When running calculations for socioeconomic indicators the user must first select the ‘start year’, which is the first year that the indicators will be calculated for, and the ‘number of years to simulate’ which determines how many years indicators will be calculated for (see Figure 5-18). For example, if the user selects a start year of 2022 and 10 years to simulate then indicators will be calculated for each year between 2022 and 2032.
Figure 5-20: Start Year and Number of Years to Simulate in the Socio-economic indicator dialog
Inputs
Inputs are a set of yearly values that are used as inputs for the custom calculations.
The only default input is yearly energy saving, which is determined from undertaking multi-year energy simulations of the model. All of the default socioeconomic indicators can be calculated from this input.
Note: Custom values for the yearly energy saving can also be inputted by changing the source from ‘from model’ to ‘custom values’. If the user wishes to use some values from the energy simulation and some custom values then this can be done by clicking on the ‘pen’ icon and manually changing the required listed values.
The user can create their own custom inputs by clicking on the ‘add model input’ button. The input can then be named and custom values for each year inserted. Custom inputs can either be used to calculate new custom indicators, or can be incorporated into the equations used to calculate the default socio-economic indicators.
Figure 5-21: Inputs in the Socio-economic indicators Dialog
Indicators
The indicators that will be calculated are then shown below the inputs (see Figure 5-20). The default socioeconomic indicators that are calculated from the yearly energy saving are: energy consumption, jobs created, disposable income, fuel poverty, property value and derelict development. The source column determines whether the initial value for the indicator used in the calculations comes from the model data or is a custom initial value, for some indicators only a custom initial value can be used. This value is set in the ‘initial value’ column. The equation used to calculate the indicator for each year is shown in the ‘terms’ columns. These equations are fully editable, allowing the user to add or remove terms based on inputs and other indicators, a full description of editing the equations is given below. To remove an indicator from the calculations, click on the cross on the far right of the table.
Figure 5-22: Indicators table
Edit Indicators
To edit the formula used to calculate a specific indicator, click on the ‘pen’ logo to open the edit indicator dialog. This then shows a list of all terms used to calculate that indicator, presented in a table (see Figure 5-21).
Figure 5-23: Edit Indicator dialog
· The indicator column allows the user to select which indicator or input is represented in the term.
· The relative year column allows the user to select for which year the indicators value should be taken from – for example a relative year of 0 gives the current years value, and a relative year of -1 gives the year before etc.
· The multiplier lets the user multiply the indicators values by a specified coefficient. The lower the multiplier is the weaker the correlation and vice-versa, if there is an inverse correlation then the multiplier value should be negative.
· The exponent column allows the user to add an exponent to the indicators term, for example if there is a squared or cubed relationship to the indicator.
· The year range column lets the user specify for what range of time the indicator in the term will have an impact on the indicator being calculated. For example, if the indicator in the term was a lagging indicator, where the effect on the output wouldn’t be apparent for 3 years, then the ‘from year’ column would be set to 3.
An example of how this works is given below for the derelict development indicator.
The derelict development value for a given year is calculated by taking the derelict development value from the previous year (relative year is set to -1) and adding the property value of the current year, to the power of 0.05. This could be described by the equation shown below:
DDn = 1 x (DDn-1)1 + 1 x (PVn)0.05
Where:
· DD is the Derelict Development indicator
· PV the Property Value indicator
· n the current year
How this equation would translate to the edit indicator dialogue box is then shown in the Figure 5-22 below. Terms in the equation have been colour coded to show where in the dialogue they would be inputted. The property value term does not have an effect on the derelict development for 7 years, so the from year is set to 7.
Figure 5-24: Edit indicator dialogue with inputs highlighted
Create a new indicator
The steps outlined above describing the edit indicator dialogue and how to edit the equations and terms used can also be applied to creating custom indicators. To add a new indicator, click on the ‘add indicator button’ and give it a name. The equation used to calculate this indicator for each year can then be set as before, by clicking on the ‘pen’ button, then adding the terms as described above. A simple example is given below.
As an example, a custom indicator entitled ‘Cumulative Savings’ could be created which would sum the total energy savings after each year. This indicator could be represented by the equation below:
CSn = 1 x CSn-1 + 1 x YSn
Where CS is the cumulative saving value, n is the current year, and YS is the yearly energy saving. To replicate this equation for the custom indicator, the following would be inputted into the edit indicator dialogue.
Figure 5-25: Creating a new indicator ‘Cumulative Savings’
To calculate values for each of the indicators over the selected time period click on the ‘run calculation’ button. The numerical results for each of the inputs and indicators for each year is then shown in the table. The ‘save results’ button allows the user to save the results of these calculations to the model.
Figure 5-26: Results for a 9-year calculation of the default indicators
After these results are saved, they can also be visualised as a line graph in the socioeconomic report. This can be viewed by selecting Extensions>IES iCD>Reports>Ready-made reports>Site Reports> SEI report. Each of the indicators with saved results are then displayed on a line graph, tracking how they have changed each year over the given time period.