This category consists of basic iCD attributes such as object type, footprint area, level of detail, and building specifications including glazing ratio, floor area, no of storeys, storey height, roof details and water fixtures. Each attribute consists of several options which can be assigned to the 3D objects based on the user’s preference.
Note that the attributes available in the “General” section will vary depending on the type of the selected object. For example, a building has attributes such as “Number of storeys” whereas a Freestanding PV would have an attribute such as “PV conversion factor”.
Here below are the different attributes that can be found in the General section:
Name: mainly states the entity name
Object type: specifies the type of the selected object
Figure 4-34 Building Query Tool – Object Type
Number of storeys: specifies the number of floors in the selected building
Building Storey height: specifies the floor height of the buildings. The user can specify either typical or individual heights for every floor (in case of multi-storey building)
Building type (ASHRAE Template only): specifies the function/utility of the built space.
Figure 4-35 Building Query Tool – Building Type
Space type (ASHRAE Template only): specifies the function of the space at a floor level within a building.
Glazing ratio (%): specifies the percentage of fenestration/ glazed surface on the external envelope of a building. Typical or individual percentage can be applied for each floor and façade in a multi-storeyed building
Roof type: specifies the kind of the roof the building has. The roof can be either flat or gable or hipped
Roof angle (degrees): specifies the angle a roof surface makes with the horizontal expressed in degrees.
Roof overlap: roof overlap/overhang is the edge of the roof that projects beyond the external walls of the building. This attribute does not apply for flat roofs.
Level of Detail - Building: the level of detail, in which a building can be represented could either be in the form of a footprint/shell or building with textured/full glazing. Reducing the level of detail helps with the fluidity of heavier models.
Max bldg. height: represents the total height of the building. Actual height of building can be imported from OSM, if the option for “Estimate building height and/or storey” is checked.
Total floor area: gives the calculated area of the entire building.
Footprint area: gives the calculated total ground floor area of the building.
Roof glazing ratio (%): it’s the percentage of glazed surface on the roof.
Water fixtures: this specifies the water flowrates (or water volume per use) for different water fixtures & fittings in the building. For water simulation, they could either be set to default (which takes default values based on the building type) or customised based on the manufacturer details/calculations.
Z axis offset: the placement of the building above the ground surface or the z- axis distance can be specified here