4.1. iCD objects

iCD models are composed of various type of objects which meet different purposes. Each iCD object type has a specific range of attributes to which different values can be assigned. Attributes are characteristics that define the object. Some of them are also used as inputs for energy and water simulations. It is thus extremely important to define them properly.
Here below is a list of the object that can be modelled in iCD.
Buildings
Buildings are one of the most important object types in iCD as they are the objects most analyses are performed on. They carry a range of attributes that can be set and modified. Buildings’ attributes can be as general as the building type or its construction date but can also be more specific for the purpose of energy simulation like envelope performances, HVAC systems, energy simulation results etc.
More information on buildings and their attributes can be found in the chapter 4.9 Editing Data.
Shades: Local, topographical and vegetated
Local shades, Topographical shades and Vegetated shades are objects that cast shadow over building envelope / glazed areas. These object types can be used to model protection against radiative solar heat gain or natural landforms that alter the global solar exposure over a building.
Adjacent building
Adjacent building is an object type that can be used to model buildings which do not need to be subject to analyses. It is important to note that in iCD, adjacent buildings do not have the same level of details and do not carry as many attributes as regular buildings. No analysis can be performed on an adjacent building. However, adjacent buildings cast shadow over buildings and have an impact on solar heat gain.
Road
Road is an object type used to model roads and streets in iCD. It is an essential object in order to run accessibility and walkability assessments.
Pavement/ Sidewalk
Pavement / Sidewalk is an object type that allows to model Pavement or sidewalks in iCD. In the absence of roads pavement can be used in order to run accessibility and walkability assessments.
Hard landscape
Hard landscape and Pervious hard landscape are object types that allow to model hard landscape elements in iCD such as stones, rocks or pavement. Modelling landscape as a Hard landscape or a pervious hard landscape has an incidence on site rainwater runoffs.
Soft landscape
Soft landscapes (turf, shrubs, ground cover, mixed vegetation and wetlands) are object types that allow to model soft landscape elements in iCD. Modelling soft landscape depending on its type has an incidence on site rainwater runoffs.
Parking Bay
Parking bay is an object type that allows the user to model parking lots in iCD. Modelling parking bays has an effect on site rainwater runoffs.
Water
Water is an object type that allow to model bodies of water in iCD.
Boundary
Boundary is an object type that allows to model geographical areas which can be used for different purposes. More information on boundaries can be found in chapter 4.14 Boundaries.
Freestanding PV
Freestanding PV is an object type that allows to model Photovoltaic solar panels. Freestanding PV can generate renewable electricity that can be analysed in the Site renewable reports.
More information on PV panels can be found in chapter 4.10 Photovoltaic (PV) panels.
Tree 
Tree is an object type used to model trees around the site. Trees in iCD cast shadow over buildings and have an impact on solar heat gain. Tree objects also provide carbon sequestration to a site, and have a monthly water consumption, these can be viewed in the site renewables report and water reports respectively.  More information on Trees can be found in chapter 4.11 Trees.
Street light 
This object type models streetlights and lampposts. They have an energy consumption which can be viewed in energy/carbon reports and exported to iSCAN. Time switch profiles and dimming profiles for street lights can be set.  More information on Street lights can be found in chapter 4.12 Street lights.
EV chargers 
This object type is used to model electric vehicle chargers. Similar to the street lights object, it has an energy consumption that can be viewed in reports and exported to iSCAN. The maximum power and operational profiled of the EV charger can be set. More information on EV chargers can be found in chapter  4.13 EV chargers.
 