Copy
|
Copies the current output to the Windows clipboard for pasting into another application.
|
|
Save
|
Saves the output to the relevant file format.
|
|
Print
|
Prints the display directly to a selected printer.
|
|
Report
|
Creates a HTML report when results are being viewed as a table.
|
|
Hide
|
Minimises the chart so that it can be reactivated again by selecting the chart in the chart list.
|
|
Close
|
Destroys the chart and closes the window, removing it from the chart list.
|
|
Set Dates
|
Changes the days (or time) over which you want to look at results
|
|
X-Y Line Graph
|
Changes the mode to an X-Y plot
|
|
Data Table
|
Changes the display to the source data, displayed in tabular format
|
|
Snapshot
|
Shows data at a specific time and date
|
|
Synopsis
|
Summarises the data, in terms of minimum value, maximum value and mean value over the currently selected period
|
|
Ranges
|
Allows you to test the data over the currently selected dates (above/below/between set values).
|
|
Monthly Totals
|
Allows you to summarise data totals over calendar months. Primarily intended for use with variables which are given in watts or kW
|
|
Peak time table
|
Identifies the peak time for the selected variable and shows any coincident variable data chosen in tabular form
|
|
Peak day table
|
Identifies the peak day for the selected variable and shows any coincident variable data chosen in tabular form
|
|
Peak day graph
|
Identifies the peak day for the selected variable and shows any coincident variable data chosen in graphical form
|
|
Variable
|
Allows you to pick the single variable to be tested.
|
|
Test Type
|
Allows you to select how the test is to be carried out (above certain values, below certain values, or between set limits).
‘Above/below set points’ tests against the room heating and cooling set points as defined in Room Conditions of the thermal template.
|
|
Values
|
Specifies the limits to be used. The number of steps specifies the number of equal graduations to be used between the specified limits.
|
|
Day/Time
|
Specifies which week days are to be tested within the currently selected period and also which times of day are to be included.
‘Occupied times only’ restricts the test to only times when there are people in the room as defined by Occupancy gains in thermal template.
|
|
Model Data
|
Cooling Calculation Data
|
Heating Calculation Data
|
|
Project file: "0511-02-FormulaProfiles.mit"
|
Cooling results file: "0511-02-FormulaProfiles.clg"
|
Heating results file: "0511-02-FormulaProfiles.htg"
|
|
Model total floor area = 42.7 m²
|
Calculated at 14:49 on 03/Nov/05
|
Calculated at 14:49 on 03/Nov/05
|
|
Model total volume = 110.6 m³
|
Calc. Period: May - Sep
|
Calc. Period: January
|
|
Number of rooms = 4
|
|
|
|
System
|
Room load (kW)
|
Air heating load (kW)
|
Boiler load
|
|||
|
Heating plant sens.
|
Hum. plant
|
System air
|
Aux mech vent
|
(kW)
|
(W/m²)
|
|
|
Main system
|
6.85
|
1.31
|
0.00
|
0.00
|
8.98
|
210.25
|
|
Auxiliary Mech Vent
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
n/a
|
|
Total
|
6.85
|
1.31
|
0.00
|
0.00
|
8.98
|
210.25
|
|
Room
|
Air temp. (C)
|
Conduction gain (kW)
|
Air system input sensible (kW)
|
Ventilation gain (kW)
|
Heating plant sensible load (kW)
|
|||
|
External
|
Internal
|
Aux mech vent
|
Infiltration
|
Natural vent
|
||||
|
Test Room
|
19.00
|
-0.60
|
-0.00
|
0.00
|
-1.11
|
0.00
|
0.00
|
1.71
|
|
Test Room
|
19.00
|
-0.60
|
-0.00
|
0.00
|
-1.11
|
0.00
|
0.00
|
1.71
|
|
Test Room
|
19.00
|
-0.60
|
-0.00
|
0.00
|
-1.11
|
0.00
|
0.00
|
1.71
|
|
Test Room
|
19.00
|
-0.60
|
-0.00
|
0.00
|
-1.11
|
0.00
|
0.00
|
1.71
|
|
Peak
|
Room load (kW)
|
System air clg. load (kW)
|
Aux mech vent clg. load (kW)
|
Chillers load
|
|||||
|
Day
|
Date
|
Cooling plant sens.
|
Dehum. plant
|
Sens.
|
Lat.
|
Sens.
|
Lat.
|
(kW)
|
(W/m²)
|
|
Jul
|
16:30
|
5.07
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
5.33
|
124.81
|
|
System
|
Peak
|
Room load (kW)
|
System air clg. load (kW)
|
Aux mech vent clg. load (kW)
|
Chiller load
|
|||||
|
Day
|
Date
|
Cooling plant sens.
|
Dehum. plant
|
Sens.
|
Lat.
|
Sens.
|
Lat.
|
(kW)
|
(W/m²)
|
|
|
Main system
|
Jul
|
16:30
|
5.07
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
5.33
|
124.81
|
|
Auxiliary Mech Vent
|
May
|
00:30
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
0.00
|
n/a
|
|
Room
|
Peak
|
Peak Space conditioning sensible (kW)
|
Air flow rate (l/s)
|
|
|
Test Room
|
Jul
|
16:30
|
1.5
|
160
|
|
Test Room
|
Jul
|
14:30
|
1.2
|
128
|
|
Test Room
|
Jul
|
16:30
|
1.4
|
150
|
|
Test Room
|
Jul
|
15:30
|
1.0
|
103
|
|
All rooms in system
|
|
|
5.2
|
541.4
|
|
Room
|
Peak
|
Air temp. (C)
|
Load (kW)
|
|||
|
Day
|
Date
|
Cooling plant sensible
|
Dehumidification plant
|
Cooling + dehum plant
|
||
|
Test Room
|
Jul
|
16:30
|
23.00
|
1.54
|
0.00
|
1.54
|
|
Test Room
|
Jul
|
14:30
|
23.00
|
1.24
|
0.00
|
1.24
|
|
Test Room
|
Jul
|
16:30
|
23.00
|
1.44
|
0.00
|
1.44
|
|
Test Room
|
Jul
|
15:30
|
23.00
|
1.00
|
0.00
|
1.00
|