Thermal bridging – 90.1 2019 ECB

This section applies to:
ASHRAE 90.1 2019 ECB
 
If the Coefficient (simple) approach is selected in VE preferences:

Baseline building the thermal bridging coefficient values for each construction on the APcdb > Thermal bridging tab are fixed, un-editable and set as follows:
For climate zones 0-3 the value will be set to zero.
 
If the Psi value (detailed) approach is selected in VE preferences:
Random thermal bridges are drawn in the model and assigned a Chi value via ApCDB > Random thermal bridge type.
For climate zones 0-3 the Psi & Chi values should be set to zero.
 
Random thermal bridges drawn in the model will be un-editable and set to default values as table A10.1.
 
For climate zones 0-3 the Psi & Chi values should be set to zero.
 
Caution: regarding Psi value dimensional conventions; users should ensure that custom values entered respect the dimensional convention set in VE preferences. In the USA (ASHRAE 90.1 but not ASHRAE RP 1365) the external plane convention is typical.