Material Description
|
Conductivity
|
Sp. Heat Capacity
|
Density
|
|
|
(W/mK)
|
(J/kgK)
|
(kg/m3)
|
|
Asphalts & Other Roofing Finishes
|
|
|
|
|
Asbestos Cement Decking
|
0.360
|
1050
|
1500
|
|
Asbestos Cement Sheet
|
0.360
|
1050
|
700
|
|
Asphalt
|
0.500
|
1000
|
1700
|
|
Felt/Bitumen Layers
|
0.500
|
1000
|
1700
|
|
Asphalt/Asbestos Tiles
|
0.550
|
837
|
1900
|
|
Roofing Felt
|
0.190
|
837
|
960
|
|
Asphalt Mastic Roofing
|
1.150
|
837
|
2325
|
|
Built-Up Roof – BR01
|
0.162
|
1464
|
1121
|
|
Roof Gravel/Slag – RG01
|
1.442
|
881
|
1674
|
|
|
|
|
|
|
|
|
|
|
|
Boards, Sheets & Deckings
|
|
|
|
|
Asbestos Cement Decking
|
0.360
|
1050
|
1500
|
|
Asbestos Cement Sheet
|
0.360
|
1050
|
700
|
|
Fibreboard
|
0.060
|
1000
|
300
|
|
Gypsum Plasterboard
|
0.160
|
840
|
950
|
|
Polyurethane Board
|
0.025
|
1400
|
30
|
|
Hardboard (Medium)
|
0.080
|
2000
|
600
|
|
Hardboard (Standard)
|
0.130
|
2000
|
900
|
|
Cork Board
|
0.040
|
1888
|
160
|
|
Chipboard
|
0.150
|
2093
|
800
|
|
Weatherboard
|
0.140
|
2000
|
650
|
|
Perlite Plasterboard
|
0.180
|
837
|
800
|
|
Cratherm Board
|
0.050
|
837
|
176
|
|
Anti-Sun Glass Cladding
|
1.050
|
750
|
2500
|
|
Plate-Glass Cladding
|
0.760
|
837
|
2710
|
|
4mm Clear Float Cladding
|
1.050
|
750
|
2500
|
|
Lightweight Metallic Cladding
|
0.290
|
1000
|
1250
|
|
Asbestos-Cement Board
|
0.580
|
1000
|
1900
|
|
Fibreboard – Tile & Lay-In Panel
|
0.058
|
600
|
290
|
|
Paperboard – Laminated
|
0.072
|
1400
|
480
|
|
Hardboard – Medium Density
|
0.105
|
1300
|
800
|
|
Paperboard – Homogeneous From Repulped Paper
|
0.072
|
1200
|
480
|
|
Hardboard – High Density
|
0.120
|
1300
|
880
|
|
Hardboard – Standard Tempered Grade
|
0.144
|
1300
|
1010
|
|
Particleboard – Low Density
|
0.102
|
1300
|
590
|
|
Particleboard – Medium Density
|
0.135
|
1300
|
800
|
|
Particleboard – High Density
|
0.170
|
1300
|
1000
|
|
Asbestos-Cement Board – AB01
|
0.597
|
837
|
1922
|
|
Cement Mortar – CM01
|
0.721
|
837
|
1858
|
|
Particle Board Underlay – PB04
|
0.311
|
1213
|
1202
|
|
Hard Board Medium Density Siding – HB01
|
0.094
|
1171
|
641
|
|
Hard Board Medium Density Others – HB02
|
0.105
|
1297
|
801
|
|
Hard Board High Density – HB03
|
0.118
|
1381
|
881
|
|
Hard Board High Density Standard Service Tempered – HB04
|
0.144
|
1381
|
1009
|
|
|
|
|
|
|
|
|
|
|
|
Brick & Block Work
|
|
|
|
|
Brickwork (Outer Leaf)
|
0.840
|
800
|
1700
|
|
Brickwork (Inner Leaf)
|
0.620
|
800
|
1700
|
|
Concrete Block (Heavyweight)
|
1.630
|
1000
|
2300
|
|
Concrete Block (Medium)
|
0.510
|
1000
|
1400
|
|
Concrete Block (Lightweight)
|
0.190
|
1000
|
600
|
|
Concrete Paviour
|
0.960
|
840
|
2000
|
|
Foam Slag
|
0.250
|
960
|
1040
|
|
Vermiculite Insulating Brick
|
0.270
|
837
|
700
|
|
Aerated Concrete Block
|
0.240
|
1000
|
750
|
|
Thermalite - High Strength
|
0.190
|
1050
|
760
|
|
Thermalite 'Turbo'
|
0.110
|
1050
|
480
|
|
Thermalite 'Shield'/'Smooth Face'
|
0.170
|
1050
|
650
|
|
Glass Block
|
0.700
|
837
|
2500
|
|
Common Brick – BK01
|
0.721
|
837
|
1922
|
|
Face Brick – BK04
|
1.310
|
921
|
2083
|
|
Face Brick – HF-A2
|
1.331
|
921
|
2083
|
|
Face Brick – HF-A7
|
1.331
|
921
|
2003
|
|
Common Brick – HF-C4
|
0.727
|
837
|
1922
|
|
|
|
|
|
|
|
|
|
|
|
Carpet
|
|
|
|
|
Wilton Carpet
|
0.060
|
1360
|
186
|
|
Simulated Sheeps Wool
|
0.060
|
1360
|
198
|
|
Wool Felt Underlay
|
0.040
|
1360
|
160
|
|
Cellular Rubber Underlay
|
0.100
|
1360
|
400
|
|
Synthetic Carpet
|
0.060
|
2500
|
160
|
|
|
|
|
|
|
Concrete
|
|
|
|
|
Aerated Concrete Slab
|
0.160
|
840
|
500
|
|
Cast Concrete (Dense)
|
1.400
|
840
|
2100
|
|
Cast Concrete (Lightweight)
|
0.380
|
1000
|
1200
|
|
Cast Concrete
|
1.130
|
1000
|
2000
|
|
Concrete Block (Heavyweight)
|
1.630
|
1000
|
2300
|
|
Concrete Block (Medium)
|
0.510
|
1000
|
1400
|
|
Concrete Block (Lightweight)
|
0.190
|
1000
|
600
|
|
Concrete Paviour
|
0.960
|
840
|
2000
|
|
Foam Slag
|
0.250
|
960
|
1040
|
|
Aerated Concrete Block
|
0.240
|
1000
|
750
|
|
Refactory Insulating Concrete
|
0.250
|
837
|
1050
|
|
Vermiculite Aggregate
|
0.170
|
837
|
450
|
|
Concrete Tiles
|
1.100
|
837
|
2100
|
|
Heavyweight Concrete Dried Aggregate – CC01
|
1.310
|
837
|
2243
|
|
Heavyweight Concrete Undried Aggregate – CC11
|
1.802
|
837
|
2243
|
|
Heavyweight Concrete Undried Aggregate – HF-C12
|
1.730
|
837
|
2243
|
|
Lightweight Concrete – 80 Lbs – CC21
|
0.36
|
837
|
1282
|
|
Lightweight Concrete – 30 Lbs – CC31
|
0.130
|
837
|
481
|
|
Lightweight Concrete – 40 Lbs – HF-C14
|
0.173
|
837
|
641
|
|
Lightweight Concrete – HF-C2
|
0.380
|
837
|
609
|
|
Heavyweight Concrete Block - Hollow – CB01
|
0.812
|
837
|
1618
|
|
Heavyweight Concrete Block - Concrete-Filled – CB02
|
1.310
|
837
|
2234
|
|
Heavyweight Concrete Block - Perlite-Filled – CB03
|
0.384
|
837
|
1650
|
|
Heavyweight Concrete Block – Part-Filled Concrete – CB04
|
1.011
|
837
|
1826
|
|
Heavyweight Concrete Block – Concrete and Perlite-Filled – CB05
|
0.825
|
837
|
1842
|
|
Mediumweight Concrete Block - Hollow – CB21
|
0.519
|
837
|
1218
|
|
Mediumweight Concrete Block - Concrete-Filled – CB22
|
0.771
|
837
|
1842
|
|
Mediumweight Concrete Block - Perlite-Filled – CB23
|
0.262
|
837
|
1250
|
|
Mediumweight Concrete Block – Part-Filled Concrete – CB24
|
0.572
|
837
|
1426
|
|
Mediumweight Concrete Block – Concrete and Perlite-Filled – CB25
|
0.431
|
837
|
1442
|
|
Lightweight Concrete Block - Hollow – CB41
|
0.384
|
837
|
1041
|
|
Lightweight Concrete Block - Concrete-Filled – CB42
|
0.639
|
837
|
1666
|
|
Lightweight Concrete Block - Perlite-Filled – CB43
|
0.220
|
837
|
1073
|
|
Lightweight Concrete Block – Part-Filled Concrete – CB44
|
0.486
|
837
|
1250
|
|
Lightweight Concrete Block – Concrete and Perlite-Filled – CB45
|
0.360
|
837
|
1266
|
|
|
|
|
|
|
|
|
|
|
|
Gravels, Beddings Etc.
|
|
|
|
|
Stone Chippings
|
0.960
|
1000
|
1800
|
|
Gravel
|
0.360
|
840
|
1840
|
|
Gravel-Based Soil
|
0.520
|
184
|
2050
|
|
Tile Bedding
|
1.400
|
650
|
2100
|
|
|
|
|
|
|
|
|
|
|
|
Insulating Materials
|
|
|
|
|
Eps Slab
|
0.035
|
1400
|
25
|
|
Silicon
|
0.180
|
1004
|
700
|
|
Glass-Fibre Quilt
|
0.040
|
840
|
12
|
|
Glass-Fibre Slab
|
0.035
|
1000
|
25
|
|
Mineral Fibre Slab
|
0.035
|
1000
|
30
|
|
Phenolic Foam
|
0.040
|
1400
|
30
|
|
Polyurethane Board
|
0.025
|
1400
|
30
|
|
Uf Foam
|
0.040
|
1400
|
10
|
|
Wood Wool Slab
|
0.100
|
1000
|
500
|
|
Vermiculite Insulating Brick
|
0.270
|
837
|
700
|
|
Refactory Insulating Concrete
|
0.250
|
837
|
1050
|
|
Glasswool
|
0.040
|
670
|
200
|
|
Thermalite - High Strength
|
0.190
|
1050
|
760
|
|
Thermalite 'Turbo'
|
0.110
|
1050
|
480
|
|
Thermalite 'Shield'/'Smooth Face'
|
0.170
|
1050
|
650
|
|
Siporex
|
0.120
|
1004
|
550
|
|
P.V.C
|
0.160
|
1004
|
1379
|
|
Polystyrene
|
0.030
|
1380
|
25
|
|
Hard Rubber
|
0.150
|
1000
|
1200
|
|
Cratherm Board
|
0.050
|
837
|
176
|
|
Uf Foam Two
|
0.030
|
1764
|
30
|
|
Uf Foam Two
|
0.030
|
1764
|
30
|
|
Lightweight Metallic Cladding
|
0.290
|
1000
|
1250
|
|
Dense Eps Slab Insulation (styrofoam)
|
0.025
|
1400
|
30
|
|
Cellular Glass
|
0.050
|
800
|
136
|
|
Glass-Fibre – Organic Bonded
|
0.036
|
1000
|
100
|
|
Expanded Perlite – Organic Bonded
|
0.052
|
1300
|
16
|
|
Expanded Rubber - Rigid
|
0.032
|
1700
|
72
|
|
Cellular Polyurethane
|
0.023
|
1600
|
24
|
|
Cellular Polyisocyanurate
|
0.023
|
900
|
32
|
|
Cellular Phenolic – Mineral Fibre With Resin Binder
|
0.042
|
700
|
240
|
|
Cement Fibre Slab – Shredded Wood With Magnesia Oxysulfide Cement Binder
|
0.082
|
1300
|
350
|
|
Vermiculite - Exfoliated
|
0.068
|
1300
|
120
|
|
Felt & Membrane – Felt – HF-E3
|
0.190
|
1674
|
1121
|
|
Felt & Membrane – Finish – HF-A6
|
0.415
|
1088
|
1249
|
|
Mineral Wool/Fibre – Batt – IN01
|
0.043
|
837
|
10
|
|
Mineral Wool/Fibre – Fill – IN11
|
0.046
|
837
|
10
|
|
Mineral Wool/Fibre – Fill – IN12
|
0.046
|
837
|
11
|
|
Cellulose Fill – IN13
|
0.039
|
1381
|
48
|
|
Insulation Board – HF-B2
|
0.043
|
1381
|
48
|
|
Insulation Board – HF-B5
|
0.043
|
837
|
32
|
|
Preformed Mineral Board – IN21
|
0.042
|
711
|
240
|
|
Expanded Polystyrene – IN31
|
0.035
|
1213
|
29
|
|
Expanded Polyurethane – IN41
|
0.023
|
1590
|
24
|
|
Urea Formaldehyde – IN51
|
0.035
|
1255
|
11
|
|
Insulation Board Sheathing – IN61
|
0.055
|
1297
|
288
|
|
Insulation Board Shingle Backer – IN63
|
0.058
|
1297
|
288
|
|
Insulation Board Nail Base Sheathing – IN64
|
0.064
|
1297
|
400
|
|
Preformed Roof Insulation – IN71
|
0.052
|
837
|
256
|
|
|
|
|
|
|
|
|
|
|
|
Metal
|
|
|
|
|
Steel
|
50.000
|
480
|
7800
|
|
Copper
|
200.000
|
418
|
8900
|
|
Aluminium
|
160.000
|
896
|
2800
|
|
Lightweight Metallic Cladding
|
0.290
|
1000
|
1250
|
|
Steel Siding – HF-A3
|
44.970
|
418
|
7690
|
|
|
|
|
|
|
|
|
|
|
|
Plaster
|
|
|
|
|
Plaster (Dense)
|
0.500
|
1000
|
1300
|
|
Plaster (Lightweight)
|
0.160
|
1000
|
600
|
|
Gypsum Plasterboard
|
0.160
|
840
|
950
|
|
Perlite Plasterboard
|
0.180
|
837
|
800
|
|
Gypsum Plastering
|
0.420
|
837
|
1200
|
|
Perlite Plastering
|
0.080
|
837
|
400
|
|
Vermiculite Plastering
|
0.200
|
837
|
720
|
|
Plaster Ceiling Tiles
|
0.380
|
840
|
1120
|
|
Cement Plaster
|
0.720
|
800
|
1860
|
|
Perlite Plaster
|
0.220
|
1300
|
720
|
|
Perlite Plaster – Sand Aggregate
|
0.810
|
800
|
1680
|
|
Cement Plaster – With Sand Aggregate – CM03
|
0.721
|
837
|
1858
|
|
Gypsum/ Plaster Board – HF-E1
|
0.160
|
837
|
801
|
|
Gypsum Plaster Lightweight Aggregate– GP04
|
0.230
|
837
|
721
|
|
Gypsum Plaster – Sand Aggregate– GP06
|
0.819
|
837
|
1682
|
|
|
|
|
|
|
|
|
|
|
|
Screeds And Renders
|
|
|
|
|
External Rendering
|
0.500
|
1000
|
1300
|
|
Screed
|
0.410
|
840
|
1200
|
|
Granolithic Render/Screed
|
0.870
|
837
|
2085
|
|
Stucco – HF-A1
|
0.721
|
837
|
2659
|
|
|
|
|
|
|
|
|
|
|
|
Sands, Stones And Soils
|
|
|
|
|
Stone Chippings
|
0.960
|
1000
|
1800
|
|
Gravel
|
0.360
|
840
|
1840
|
|
Gravel-Based Soil
|
0.520
|
184
|
2050
|
|
Sandstone
|
1.830
|
712
|
2200
|
|
Granite (Red)
|
2.900
|
900
|
2650
|
|
Marble (White)
|
2.770
|
802
|
2600
|
|
Cultivated Sandy Soil 12.5%D.W. Moisture
|
1.790
|
1190
|
1800
|
|
Cultivated Sandy Soil 25.0%D.W. Moisture
|
2.220
|
1480
|
2000
|
|
Cultivated Clay Soil 12.5%D.W. Moisture
|
1.180
|
1250
|
1800
|
|
Cultivated Clay Soil 25.0%D.W. Moisture
|
1.590
|
1550
|
2000
|
|
Cultivated Peat Soil 133%D.W. Moisture
|
0.290
|
3300
|
700
|
|
Cultivated Peat Soil 366%D.W. Moisture
|
0.500
|
3650
|
1100
|
|
Dry Limestone Sub-Soil
|
1.490
|
840
|
2180
|
|
London Clay
|
1.410
|
1000
|
1900
|
|
Soil
|
1.729
|
837
|
1842
|
|
Stone – ST01
|
1.802
|
837
|
2243
|
|
Stone – HF-A3
|
1.435
|
1674
|
881
|
|
Terrazzo – TZ01
|
1.802
|
837
|
2243
|
|
|
|
|
|
|
|
|
|
|
|
Tiles
|
|
|
|
|
Clay Tile
|
0.840
|
800
|
1900
|
|
Concrete Tiles
|
1.100
|
837
|
2100
|
|
Slate Tiles
|
2.000
|
753
|
2700
|
|
Plastic Tiles
|
0.500
|
837
|
1950
|
|
Rubber Tiles
|
0.300
|
2000
|
1600
|
|
Cork Tiles
|
0.080
|
1800
|
530
|
|
Asphalt/Asbestos Tiles
|
0.550
|
837
|
1900
|
|
P.V.C./Asbestos Tiles
|
0.850
|
837
|
2000
|
|
Ceiling Tiles
|
0.056
|
1000
|
380
|
|
Plaster Ceiling Tiles
|
0.380
|
840
|
1120
|
|
Lightweight Metallic Cladding
|
0.290
|
1000
|
1250
|
|
Acoustical Tile – Mineral Fibreboard
|
0.050
|
800
|
290
|
|
Acoustic Tile - AC01
|
0.057
|
1339
|
288
|
|
Acoustic Tile – HF-E5
|
0.061
|
2142
|
480
|
|
Hollow Clay Tile – 1 Cell – CT01
|
0.498
|
837
|
1121
|
|
Hollow Clay Tile – 2 Cells – CT03
|
0.571
|
837
|
1121
|
|
Hollow Clay Tile – 3 Cells – CT06
|
0.692
|
837
|
1121
|
|
Clay Tile – HF-C1
|
0.571
|
837
|
1121
|
|
Paver – Clay Tile – CT11
|
1.802
|
837
|
1922
|
|
Slate – SL01
|
1.442
|
1464
|
1602
|
|
|
|
|
|
|
|
|
|
|
|
Timber
|
|
|
|
|
Timber Flooring
|
0.140
|
1200
|
650
|
|
Plywood (Lightweight)
|
0.150
|
2500
|
560
|
|
Plywood (Heavyweight)
|
0.150
|
1420
|
700
|
|
Wood Blocks
|
0.140
|
1200
|
650
|
|
Wood Wool Slab
|
0.100
|
1000
|
500
|
|
Hardboard (Medium)
|
0.080
|
2000
|
600
|
|
Hardboard (Standard)
|
0.130
|
2000
|
900
|
|
Pine (20% Moist)
|
0.140
|
2720
|
419
|
|
Cork Board
|
0.040
|
1888
|
160
|
|
Chipboard
|
0.150
|
2093
|
800
|
|
Weatherboard
|
0.140
|
2000
|
650
|
|
Oak (Radial)
|
0.190
|
2390
|
700
|
|
Cork Tiles
|
0.080
|
1800
|
530
|
|
Plywood – PW01
|
0.115
|
1213
|
545
|
|
Soft Wood – WD01
|
0.115
|
1381
|
513
|
|
Hard Wood – WD11
|
0.158
|
1255
|
721
|
|
Wood – HF-B7
|
0.121
|
837
|
593
|
|
Plywood – Douglas Fir
|
0.120
|
1200
|
540
|
|
Shingle Wood – WS01
|
0.115
|
1255
|
513
|
|
Description
|
Refl
|
Absorp
|
Trans
|
Refr
|
|
|
|
|
|
|
|
Clear Float 4mm
|
0.07
|
0.11
|
0.82
|
1.526
|
|
Clear Float 6mm
|
0.07
|
0.15
|
0.78
|
1.526
|
|
Clear Float 10mm
|
0.07
|
0.23
|
0.7
|
1.526
|
|
Clear Float 12mm
|
0.06
|
0.27
|
0.67
|
1.526
|
|
'Spectrafloat' 6mm 51/65 (Bronze)
|
0.1
|
0.36
|
0.54
|
1.526
|
|
'Antisun' Float 6mm 72/62 (Green)
|
0.05
|
0.49
|
0.46
|
1.526
|
|
'Antisun' Float 4mm 55/68 (Grey)
|
0.05
|
0.4
|
0.55
|
1.526
|
|
'Antisun' Float 6mm 42/60 (Grey)
|
0.05
|
0.53
|
0.42
|
1.526
|
|
'Antisun' Float 10mm 25/49 (Grey)
|
0.04
|
0.71
|
0.25
|
1.526
|
|
'Antisun' Float 12mm 19/45 (Grey)
|
0.04
|
0.77
|
0.19
|
1.526
|
|
'Antisun' Float 4mm 61/70 (Bronze)
|
0.06
|
0.36
|
0.58
|
1.526
|
|
'Antisun' Float 6mm 50/62 (Bronze)
|
0.05
|
0.49
|
0.46
|
1.526
|
|
'Antisun' Float 10mm 33/51 (Bronze)
|
0.04
|
0.67
|
0.29
|
1.526
|
|
'Antisun' Float 12mm 27/47 (Bronze)
|
0.04
|
0.73
|
0.23
|
1.526
|
|
'Antisun' Float 6mm 54/62 (Blue)
|
0.05
|
0.49
|
0.46
|
1.526
|
|
Reflectafloat 6mm 35/53 (Silver)
|
0.28
|
0.29
|
0.43
|
1.526
|
|
'Suncool' Classic 6mm 20/33 (Blue)
|
0.21
|
0.64
|
0.15
|
1.526
|
|
'Suncool' Classic 6mm 30/39 (Blue)
|
0.18
|
0.61
|
0.21
|
1.526
|
|
'Suncool' Classic 6mm 40/50 (Blue)
|
0.1
|
0.58
|
0.32
|
1.526
|
|
'Suncool' Classic 6mm 10/24 (Bronze)
|
0.21
|
0.73
|
0.06
|
1.526
|
|
'Suncool' Classic 6mm 10/23 (Silver)
|
0.32
|
0.6
|
0.08
|
1.526
|
|
'Suncool' Classic 6mm 20/34 (Silver)
|
0.18
|
0.66
|
0.16
|
1.526
|
|
'Suncool' Classic 10mm 10/33 (Blue)
|
0.19
|
0.66
|
0.15
|
1.526
|
|
'Suncool' Classic 10mm 30/38 (Blue)
|
0.17
|
0.63
|
0.2
|
1.526
|
|
'Suncool' Classic 10mm 40/49 (Blue)
|
0.09
|
0.6
|
0.31
|
1.526
|
|
'Suncool' Classic 10mm 10/24 (Bronze)
|
0.19
|
0.76
|
0.05
|
1.526
|
|
'Suncool' Classic 10mm 10/23 (Silver)
|
0.3
|
0.62
|
0.08
|
1.526
|
|
'Suncool' Classic 10mm 20/34 (Silver)
|
0.16
|
0.69
|
0.15
|
1.526
|
|
'Suncool' Classic 6mm 20/34 (Silver)
|
0.18
|
0.66
|
0.16
|
1.526
|
|
'Suncool' Classic 10mm 20/33 (Blue)
|
0.19
|
0.66
|
0.15
|
1.526
|
|
Stopsol 4mm (Clear)
|
0.25
|
0.22
|
0.53
|
1.526
|
|
Stopsol 5mm (Clear)
|
0.25
|
0.24
|
0.51
|
1.526
|
|
Stopsol 6mm (Clear)
|
0.25
|
0.25
|
0.5
|
1.526
|
|
Stopsol 8mm (Clear)
|
0.25
|
0.28
|
0.47
|
1.526
|
|
Stopsol 10mm (Clear)
|
0.24
|
0.31
|
0.45
|
1.526
|
|
Stopsol 4mm (Bronze)
|
0.27
|
0.38
|
0.35
|
1.526
|
|
Stopsol 5mm (Bronze)
|
0.27
|
0.41
|
0.32
|
1.526
|
|
Stopsol 6mm (Bronze)
|
0.26
|
0.45
|
0.29
|
1.526
|
|
Stopsol 8mm (Bronze)
|
0.26
|
0.51
|
0.23
|
1.526
|
|
Stopsol 10mm (Bronze)
|
0.26
|
0.56
|
0.18
|
1.526
|
|
Stopsol 6mm (Silver)
|
0.2
|
0.37
|
0.43
|
1.526
|
|
Kappafloat 4mm (Champagne)
|
0.17
|
0.22
|
0.61
|
1.526
|
|
Kappafloat 4mm (Neutral)
|
0.2
|
0.14
|
0.66
|
1.526
|
|
Kappafloat 6mm (Champagne)
|
0.16
|
0.26
|
0.58
|
1.526
|
|
Kappafloat 6mm (Neutral)
|
0.2
|
0.17
|
0.63
|
1.526
|
|
Saflex Blue-Green (Light) 5.4mm
|
0.07
|
0.19
|
0.74
|
1.526
|
|
Saflex Blue-Grey (Light) 5.4mm
|
0.06
|
0.4
|
0.54
|
1.526
|
|
Saflex Blue-Grey (Medium) 6.2mm
|
0.05
|
0.59
|
0.36
|
1.526
|
|
Saflex Bronze 5.4mm
|
0.06
|
0.41
|
0.53
|
1.526
|
|
Saflex Bronze (Light) 5.4mm
|
0.06
|
0.37
|
0.57
|
1.526
|
|
Saflex Bronze (Medium) 5.7mm
|
0.05
|
0.56
|
0.39
|
1.526
|
|
Saflex Green-Blue (Light) 5.3mm
|
0.07
|
0.18
|
0.75
|
1.526
|
|
Saflex Grey 5.4mm
|
0.05
|
0.51
|
0.44
|
1.526
|
|
Saflex Grey-Green (Light) 5.4mm
|
0.06
|
0.42
|
0.52
|
1.526
|
|
Saflex Marine Blue (Light) 5.3mm
|
0.06
|
0.35
|
0.59
|
1.526
|
|
Saflex Marine Blue (Medium) 5.3mm
|
0.05
|
0.56
|
0.39
|
1.526
|
|
Saflex Pink (Light) 6.3mm
|
0.06
|
0.31
|
0.63
|
1.526
|
|
Saflex Translucent White 6.1mm
|
0.06
|
0.37
|
0.57
|
1.526
|
|
Saflex Shadowlite Smoke Brown (L) 5.4mm
|
0.06
|
0.39
|
0.55
|
1.526
|
|
Saflex Shadowlite Smoke Brown (M) 5.3mm
|
0.05
|
0.67
|
0.28
|
1.526
|
|
Saflex Shadowlite Smoke Brown (D) 6.3mm
|
0.04
|
0.86
|
0.1
|
1.526
|
|
Polycarbonate 3mm Clear
|
0.09
|
0.09
|
0.82
|
1.6
|
|
Acrylic 3mm Clear
|
0.09
|
0.06
|
0.85
|
1.49
|
|
Luxguard 6mm (Bright Silver) Cs-14
|
0.27
|
0.61
|
0.12
|
1.526
|
|
Luxguard 6mm (Bright Silver) Cs-20
|
0.22
|
0.61
|
0.17
|
1.526
|
|
Luxguard 6mm (Bright Silver) Cs-35
|
0.14
|
0.54
|
0.32
|
1.526
|
|
Luxguard 6mm (Pewter) Cp-14
|
0.2
|
0.66
|
0.14
|
1.526
|
|
Luxguard 6mm (Pewter) Cp-20
|
0.16
|
0.65
|
0.19
|
1.526
|
|
Luxguard 6mm (Pewter) Cp-35
|
0.09
|
0.58
|
0.33
|
1.526
|
|
Luxguard 6mm (Bronze) Cb-14
|
0.18
|
0.69
|
0.13
|
1.526
|
|
Luxguard 6mm (Bronze) Cb-20
|
0.13
|
0.68
|
0.19
|
1.526
|
|
Luxguard 6mm (Bronze) Cb-35
|
0.08
|
0.6
|
0.32
|
1.526
|
|
Luxguard 6mm (Royal Blue) Cr-14
|
0.17
|
0.7
|
0.13
|
1.526
|
|
Luxguard 6mm (Royal Blue) Cr-20
|
0.12
|
0.69
|
0.19
|
1.526
|
|
Luxguard 6mm (Royal Blue) Cr-35
|
0.07
|
0.61
|
0.32
|
1.526
|
|
Thermoclear 8mm Polycarbonate Sheeting
|
0.05
|
0.8
|
0.15
|
1.59
|
|
Thermoclear 16mm Polycarbonate Sheeting
|
0.08
|
0.7
|
0.22
|
1.59
|
|
Perfectly Clear Glazing Material
|
0
|
0
|
1
|
1
|