Table 18 Vapour Resistivities

Material
Resistivity
 
Typical
Range
 
(GN s/kg m)
(GN s/kg m)
 
 
 
Asbestos Cement Sheeting and Substitutes:
300
200 - 1000
 
 
 
Blockwork and Brickwork:
 
 
Lightweight / aerated blocks
30
20 - 50
Medium weight blocks
50
30 - 80
Dense / clinker blocks
100
60 - 150
Common / facing brick
50
25 - 100
Sandlime / engineering brick
100
80 - 250
 
 
 
Boards etc.:
 
 
Cork board
100
50 - 200
Chipboard
500
 
Fibreboard - Plain or tile
40
15 - 60
Hardboard
600
450 - 1000
 
 
 
Carpeting:
 
 
Normal backing
10
7.0 - 20.0
Foam backed or with underlay
200
100 - 300
 
 
 
Concrete (cast):
 
 
Lightweight / aerated
40
30 - 80
Medium weight
100
60 - 150
Dense
200
 
No fines
20
 
 
 
 
Insulating Materials:
 
 
Polystyrene - expanded bead
300
100 - 600
                   - expanded extruded
1000
600 - 1300
Polyurethane foam (closed cell)
600
500 - 1000
Glass fibre
7
 
Expanded or foamed glass
10000
 
Urea formaldehyde
15
10.0 - 30.0
Vermiculite
15
 
PVC sheet or tile
1000
800 - 1300
 
 
 
Plaster:
 
 
Plaster
60
 
Plasterboard
60
 
 
 
 
Screeds and Renders:
 
 
Rendering
100
 
Screed
100
 
 
 
 
Stonework:
 
 
Granite, slate and marble
300
150 - 450
Limestone and sandstone
200
150 - 450
 
 
 
Tiles:
 
 
Roofing tile or slating
250
50 -  300
Ceramic tiling
2000
500 - 5000
 
 
 
Timber:
 
 
General
60
40 - 70
Pine
500
 
Plywood
1000
150 - 6000
Woodwool slabs
20
15 - 40
 
Source of data: BSI 5250