Systems Dataset

Load IMPACT systems
Within the IMPACT cost planning navigator, “Load IMPACT systems” when selected imports default system types that have been assigned capital cost and also operational cost that will be used in the CostPlanPro module. The default systems will then appear in the Apache system dialog.
 
 
 
 

Before loading IMPACT systems:
 
After loading IMPACT systems:
   
The full list of IMPACT systems are as follows (22 systems):
 

System costs assignment note
Systems cost is broken down into heating, cooling, hot water and ventilation costs per m² in the Apache system dialog. In reality, one particular system may not satisfy heating, cooling, or ventilation. For this reason, we have enabled the user to input their cost breakdown on the basis of heating equipment, cooling equipment, domestic hot water equipment and ventilation equipment. An example of such system would be radiators that provide heating, and possibly fan coil units that provide cooling and ventilation. Alternatively where one system may provide, heating, cooling and ventilation, the user will input total system cost in only one of the cost tabs (i.e., enter total system cost/m² in only one of the heating, cooling, or ventilation cost columns).
 
Within the default systems dataset, the following systems include total system cost for heating, cooling and ventilation, which have been assigned to the cooling tab only.
 
Commercial/Education – active chilled beam (heating, cooling & mech vent)
Commercial/Education – air con constant volume
Commercial/Education – air con dual duct VAV
Commercial/Education – air con fan coil unit
Commercial/Education – air con single duct VAV
Commercial/Education – termodeck (Heating, Cooling & Ventilation)
 
Cost templates
Two levels of templates are available:
A template has been provided for each of the following building types;
Commercial
Domestic
Education
Health
Industrial
Retail (frequent fit-in)
Retail (infrequent fit-in)
Each template stores a list of sections (categories and elements within a category) that needs to be included for a particular building type. It also stores the arrangement of these sections. Cost templates also provide a mechanism to price non-modeled items in the VE (e.g., fire alarm,  client costs, etc.) by including these items in the template and providing a pre-defined rate.
To import a template to the project, please refer to section 1.4.3.1 .
Cost calculation
Cost plan is broken down into categories, which is then broken down into elements. Some elements are further broken down into sub-elements depending on the detail of the analysis required. The total cost is then a summation of the costs from bottom up: sub-element costs -> element costs -> category costs -> project cost.
To calculate elemental cost, cost plan uses a key variable called an “element code” as an instruction macro to instruct the module how to interpret the rate and quantity, and how to retrieve them from the 3D model. The following formulas are used to calculate element/sub-element cost:
 
Base cost = Rate x Quantity x Weight
Adjusted Cost £ = Base cost x LOC factor x TPI factor x scaling factor
Cost £ /m2 = Cost £ / GIFA
 
Tender price index (TPI) adjustment % = ((target TPI – base TPI) / base TPI) x 100
Therefore TPI factor = (1 + TPI adjustment % / 100) = target TPI / base TPI;
Weighting
Weighting can be applied at either project level or elemental level to adjust the cost locally.
At project level, a variable called scaling factor is defined to allow users to adjust the project cost according to the overall project complexity and quality. This variable can be set in the Project settings tab (see section 1.4.6.5 ).
At elemental level, weighting can also be applied directly to the cost rate or through the weight variable. Three types of elemental weighting are identified:
Construction complexity factor (CF)
Cost for the same construction type (e.g. wall) can vary significantly among different building forms. This variable offers a mechanism to adjust the construction cost based on model geometry complexity. Currently the geometry complexity uses the result of the following formula if it is within range [0, 1]. It takes 0 if the formula result is less than 0; it takes 1 if the formula result is larger than 1; it takes 0.5 if the external wall gross area is 0 or if model data is not available.
1 – building footprint area / external wall gross area.
CF is applied during cost calculation when relevant element codes are selected (See section 1.2.4.13 for details). This factor is then used to select a cost rate within the low and hi cost rate range of the corresponding construction.
The current CF used is displayed in the settings dialog which can be accessed by clicking the settings toolbar button (See section 1.4.3.5 ). 
System complexity factor (SCF)
Due to the wide range of cost in systems for different buildings types or even for the same building type, this factor is introduced to allow users to adjust the system cost depending on their project at hand.
 
To use it, an Apache simulation run is required. The module will detect whether a simulation exists and use the simulation results to set SCF or use 1 by default. Once set, this factor is then used to select a cost rate with in the low and hi cost range of the corresponding system.
Construction weighting factor (CWF)
This is a generic factor specific and internal to each defined construction that allows similar constructions to have the same cost base figure but adjusted locally to take into account issues below the resolution of the VE. This allows a user to make copies of a default referenced construction and adjust the cost data without losing the referenced data. e.g.
 
Partition 13mm plasterboard / studs at 300mm CWF 1.0
Partition 13mm plasterboard / studs at 200mm CWF 1.2
 
The CWF is part of the construction definition. You can edit it on the CDB tabular edit dialog – Impact costs tab – Capital cost weighting factor, which is then passed to the cost plan weight column (see section 1.4.7.4 ).  For constructions that are not modelled within VE, you can edit the cost plan weighting columns directly to set this factor.
Location modifier
This variable allows the project cost to be adjusted according to the where it is going to be build. The idea is that same project build in London for example might be more expensive than it is built in Glasgow. A look up table of a list of UK locations is available on the project settings tab. Selection of a location will set the location factor to be used.
Tender price index (TPI)
Tender price index allows cost data from different source based on different dates to be used together in a single cost plan. This includes both a base TPI and a target TPI. Base TPI tells when the cost data used is based on. The target TPI tells when the project is going to be build. These two variables are then used to compute an adjustment factor to adjust the overall elemental cost.
A lookup table containing a list of year & quarter is implemented on the project settings tab (see section 1.4.6.3 ). Selection of a year & quarter will set the target TPI to be used. However, users can also use this facility to look up an appropriate value for base TPI.
Element codes
Element codes act as an instruction macro to instruct the module how to interpret the elemental rate and quantity, weight, and how to obtain them from the model. It also tells the module whether the TPI factor and location factor should be applied to a specific element or sub-element.

Zero Cost 
0
Zero Cost
 
 
 
This code will fix rate as 0.
By item (quantity fixed as 1)
 
1
By item (quantity fixed as 1)
 
 
This code will fix quantity as 1.
User entered
 
2
User entered
 
 
It’s up to the user to interpret the rate and quantity.
Whole building (cost)
4
Whole building (cost)
 
 

When the whole building costs data is available, this item brings up a dialog list populated from the Building estimates dataset; the list shows the building types/subtypes available. Once selected this text string is placed in the element field and the building cost selected from the range using the selected complexity / quality factors is entered into the rate field. Quantity is set to GIFA. Currently this code is not used due to lack of whole building costs data.
Non-selectable codes
 
5
NULL
6
Auto sub-element
 
 
 
These codes are non-selectable on the module interface and used for internal calculation and display purposes.
Perimeter codes
 
57
Perimeter of all windows + doors
58
Perimeter of all rooms
 
 
 
Code 57 retrieves the inside perimeter (m) of all windows and door (external and internal) into quantity. This value is for use with opening carcassing costs.
 
Code 58 retrieves the inside perimeter (m) of all spaces taken as the floor plane perimeter. This value is for use with edging carcassing costs (skirting etc.).

Volume
99
Volume
 
 
 
 
 
 




This is the volume of the building. Assign this to quantity.
Codes getting back counting of specified object
 
3
Number of storeys
31
Total Number of Windows
33
Number of External Windows
35
Number of Internal Windows
41
Total Number of Doors
43
Number of External Doors
45
Number of Internal Doors
60
Total Number of Roof lights
 
 
 
 
 
 
 


Codes getting back specified area
 
7
NIA
10
Footprint Area
11
GIFA
12
Ground Floor Area
13
Upper Floor Area
14
Roof Area
15
Suspended ceiling Area
16
Floor coverings Area
21
External Wall Area
22
Internal Wall Area
23
External Wall Glazed Area
24
Solid ceilings area
32
Total Area of Windows
34
Area of External Windows
36
Area of Internal Windows
 
42
Total Area of Doors
44
Area of External Doors
46
Area of Internal Doors
 
52
Total Area of Windows + Doors
54
Area of External Windows + Doors
56
Area of Internal Windows + Doors
61
Total Area of Roof lights
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NIA: See 1.3.7 for details.
Footprint area: the floor area in contact with the ground

Suspended ceilings and floor finishes codes
15
Suspended ceiling Area
16
Floor coverings Area
 
 
 

Code 15 will retrieve all suspended ceilings materials assigned to the constructions of "Internal Ceiling/Floor” and "Roof" type in the model, listing each material as a sub-element.
 
Code 16 will retrieve all floor coverings materials assigned to the constructions of "Internal Ceiling/Floor” and "Ground/Exposed Floor" type in the model, listing each material as a sub-element.
 
The quantity of each sub-element will be the area of the parent construction. The cost rate will be the rate of the relevant material. The id will be empty. The name will be “[construction id] material name”.

Percentage codes
These are codes from 100 to 110. See full list below:
 
100
Percentage of building costs (Cat.1-7)
101
Percentage of construction costs (Cat.1-8)
102
Percentage of construction costs (Cat.1-9)
103
Percentage of construction on-costs (Cat.9-11)
104
Percentage of construction & on-costs (Cat.1-11)
105
Percentage of project on-costs (Cat.12-13)
106
Percentage of project cost exc. rick & inflation (Cat.1-12)
 
107
Percentage of project & on-costs (Cat.1-13)
108
Percentage of project total cost (Cat.1-14)
109
Percentage of category 14 construction costs
111
Percentage of category 1 construction costs
112
Percentage of category 2 construction costs
113
Percentage of category 3 construction costs
114
Percentage of category 4 construction costs
115
Percentage of category 5 construction costs
116
Percentage of category 6 construction costs
117
Percentage of category 7 construction costs
118
Percentage of category 8 construction costs
110
Percentage of overheads and profit costs (Cat. 10)
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

They consist of the following two types.
This will instruct the module to place the sum of the costs of the specified categories into    the quantity and treat the rate value as a percentage figure (9 = 9%).
This will instructs the module to place the cost of the specified category into the quantity and treat the rate value as a percentage figure (9 = 9%).
     Percentage codes are the only codes that TPI factor and location factor are not applied.

CDB item rate & area codes
 
120
Ground Floor by CDB item rate & area
121
Upper floor by CDB item rate & area
122
Roof by CDB item rate & area
123
Roof light by CDB item rate & area
124
External Wall by CDB item rate & area
125
Internal Wall by CDB item rate & area
126
External Window by CDB item rate & area
127
Internal Window by CDB item rate & area
128
Door by CDB item rate & area
 
 
 
 
 
 
 
 
 
 
 
These items import all the specified constructions assigned in the model. Each construction is assigned to a sub-element. Quantity is area of the construction. The average cost rate (low + high / 2) is inserted in to the rate field. CWF is inserted into the weighting column. Construction name will be the name of the sub-element
 
For example, code “124. External Wall by CDB item rate & area” instructs the module to process all external wall constructions assigned to the model and  retrieve their rate, quantity and weight in the model to calculate the construction costs. Each external wall construction in the model will be displayed as a sub-element.

CDB item rate & area & CF codes
 
140
Ground Floor by CDB rate & area & CF
141
Upper floor CDB rate & area & CF
142
Roof by CDB rate & area & CF
143
Roof light by CDB rate & area & CF
144
External Wall by CDB rate & area & CF
145
Internal Wall by CDB rate & area & CF
146
External Window by CDB rate & area & CF
147
Internal Window by CDB rate & area & CF
148
Door by CDB rate & area & CF
 
 
 
 
 
 
 
 
 
 
 
These items import all the specified constructions assigned in the model. Each construction is assigned to a sub-element. Quantity is the area of the construction. The relevant cost rate is selected using CF (where in the range of low and high) and inserted in to the rate field. CWF is inserted into the weighting column.

System by type, area & SCF codes
 
151
Heating system by type & area & SCF (all in cost)
152
DHW system by type & area & SCF (all in cost)
153
Cooling system by type & area & SCF (all in cost)
154
Vent system by type & area & SCF (all in cost)
 
 
 
 

This item imports all of the specified apache systems assigned to the model. Each system is assigned to a sub-element. Quantity is area conditioned. Rate is selected from the all in cost rate range of the system using the system complexity factor SCF.  To use the SCF, users must carry out an Apache simulation. If no simulation run exists, the average cost is used. 1.0 is inserted into the weighting column.
 
On performing an apache simulation, please refer to section 1.3.9 .
Area served by lighting type (int gain)
 
161
Area served by lighting type (int gain)
 
 
Element code, “161” retrieves the floor area of rooms that have internal lighting gains assigned.
 
The cost rate is entered by the user manually. Composite cost templates will have lighting as a GIFA rate; this permits greater definition by the user.
 
On setting up room lighting, please refer to section 1.3.4 1.3.3 .
PVs by type and area
 
170
PVs by type and area
 
 
This item imports all the PV items defined under apache. Each PV item is assigned to a sub-element. Quantity is area. The cost rate is entered by the user manually.
 
On defining PV items, please refer to section 1.3.6 .
Wind turbine by Kw
 
171
Wind turbine by kW
 
 
This item imports the turbine defined under apache. Quantity is turbine size in kW. The cost rate is entered by the user manually.
 
On defining a turbine, please refer to section 1.3.6 .
CHP by kWt
 
172
CHP by kWt
 
 
This item imports the CHP defined in the renewables tab in the Apache module . Quantity is CHP size in kWt. The cost rate is entered by the user manually.
 
On defining a CHP, please refer to section 1.3.6 .
Component by item rate
 
200
Component by item rate
 
 
This code imports cost data for all assigned model components. Each component is assigned to a sub-element. Quantity is 1 for each component. The cost rate from the component attributes is inserted in to the rate field. Currently this feature is not fully implemented in VE, so users need to use CostPlanPro/LCC to edit the component rate directly under the rate element field.

Please refer to section 1.3.8  to find information on setting up components.
Occupant no. (max)
 
201
Occupant no. (max)
 
 
This code imports the number of people assigned to the model
Please refer to section 1.3.5 to find information on setting the number of occupants.

Energy utility costs related codes
The following items retrieve the peak energy data from apache loads. Quantity is peak kw. The cost rate is entered by the user manually.
 
180
Total gas peak energy kw
181
Total electrical peak energy kw
 
 
 
The following codes (182 - 192) import data from the defined aps file(s) and the Vista tariff selections.
 
189
Fuels by type Kwh & tariff data (including renewables)
 
 
This code will list all fuels used including renewables. Each fuel will be a sub-element. Quantity is annual energy consumption in kWh. The rate & fixed charge is from the tariff data (in the case of time dependent rates, an average rate for the total consumption will be imported).
 
The following codes list each individual fuel type.
 
182
Primary energy elec  Kwh & tariff data
183
Primary energy nat gas  Kwh & tariff data
184
Primary energy LPG  Kwh & tariff data
185
Primary energy oil  Kwh & tariff data
186
Primary energy coal  Kwh & tariff data
187
Primary energy biomass Kwh & tariff data
188
Primary energy biogas  Kwh & tariff data
 
 
 
 
 
 
 
 
 
The impact of renewables on energy utility costs is included in the following codes.
 
190
PV energy generated  Kwh
191
Wind energy generated  Kwh
192
CHP energy generated  Kwh
 
 
 
 
On running an apache simulation, please refer to section 1.3.9 .

Preconditions

Prior to launching the CostPlanPro module, a few things need to be setup.

Make construction adjustments and assign constructions
This can be performed via the “IMPACT cost planning” navigator or by switching to the apache module. Apache toolbar:
The general steps to setup the model constructions are:
You can then switch to the CostPlanPro module to see the changes.
 
Setting up green guide constructions
Depending on the analysis at hand, the user may select constructions/materials from the BRE Green Guide dataset, if they are suitable for the project. The main advantage of using constructions/materials from the BRE Green Guide, is that they can also be used within the LCC and LCA module. Select one of the Green Guide construction (highlighted in orange) datasets from the view menu under the construction database dialog:
 
Selecting one of the orange highlighted items will display the following dialog:
 
Choose one of the constructions,then right click and select “Copy construction(s) to project” or click “Copy selected construction(s) to project” menu item on the Actions menu on the left:
 
 
 
The copied construction will then appear in the Project constructions list:
 
Press OK. Then select assign constructions to assign imported green guide constructions to the model.
 
 
Switch to CostPlanPro, check element with code “124. External wall by CDB item rate & area” is selected.
 
 
Edit construction capital costs data
The user can edit the capital costs data (capital cost low, capital cost high and construction weighting factor CWF) of any project constructions through the “Costs/LCA” tab of the project constructions dialog by double clicking the values.
Assign floor finish and suspended ceilings materials
Floor finishes and suspended ceilings will have cost data edited at material level.
The general steps involved to setup a floor finish or a suspended ceiling are:
Open the Green Guide floor finish or suspended ceilings dataset
 
 
Select for example the floor finish dataset, then the selected materials dialog will appear. From here the user will select either “floor finishes” or “suspended ceiling” materials. The following dialog will then appear;
 
 
Select the relevant floor finish that will be imported to the project, then click the copy button in the top left hand corner, or right click and select copy material.
 
 
Double click on the construction in which you want to add the copied material, the user can then choose to add or insert the copied material. The add button will add the copied material to the bottom of the construction make-up and the insert button can be used to insert the copied material between two layers.
Once the material has been copied, it is automatically added to the “project materials” list, which can be viewed by selecting project materials.
As you can see below, all the cost items are ready for editing:

When the constructions have been assigned to the model, the user will then select the CostPlanPro module. In order for the assigned constructions to be included in the cost calculation, the user must first  add and select the relevant “element code” which will retrieve the cost data assigned to the constructions previously set up.