COMPONENTS
| ||
|
Fans
|
Filter
|
Dampers
|
|
None <Select>
|
None <Select>
|
None <Select>
|
|
Supply fan
|
Filter pressure & change
|
Outside air min + econ
|
|
Supply fan – TSP addition
|
|
Outside air no min econ
|
|
Return/Relief fan
|
|
Outside air fixed min
|
|
Exhaust fan
|
|
Outside air variable min
|
|
FCU fan
|
|
Energy recovery bypass
|
|
FPB fan
|
|
Heat-pipe/RR/whl bypass
|
|
Package terminal unit fan
|
|
Zone mixing box damper
|
|
Unit heater fan
|
|
|
|
|
|
|
|
Duct heat gain/loss
|
Heating coils
|
Cooling coils
|
|
None <Select>
|
None <Select>
|
None <Select>
|
|
SA duct heat loss/gain
|
AHU pre-heat coil
|
AHU cooling coil
|
|
RA duct heat loss/gain
|
AHU heating coil
|
FCU/act-beam cool coil
|
|
|
Zone reheat coil
|
PTAC/PTHP cooling coil
|
|
|
FCU/act-beam heat coil
|
UCS cooling coil
|
|
|
PTAC/PTHP heating coil
|
|
|
|
Elec heat coil 2nd stage
|
|
|
|
|
|
|
Heat/enthalpy exchangers
|
Moisture addition/evaporative cooling
|
Thermal battery
|
|
None <Select>
|
None <Select>
|
None <Select>
|
|
Energy recovery HX/wheel
|
Steam humidifier
|
DOAS/AHU cooling device
|
|
Heat-pipe/Run-Rnd/wheel
|
Direct-evap/spray
|
Zone cooling device
|
|
|
Indirect-evap/spray
|
|
|
|
|
|
|
Room or Zone component
|
Room or Zone without air supply
|
|
|
None <Select>
|
None <Select>
|
|
|
Occupied zone (default)
|
Occupied zone (default)
|
|
|
Thermally stratified zone
|
Heated/cooled slab zone
|
|
|
SA/UFAD plenum
|
|
|
|
Return Air (RA) plenum
|
|
|
|
Adjacent room w EA fan
|
|
|
|
INDEPENDENT CONTROLLER WITH SENSOR
| ||
|
Flow Rate
|
Dry-bulb Temperature
|
Relative Humidity
|
|
None <Select>
|
None <Select>
|
None <Select>
|
|
Cooling airflow VAV/CAV
|
OA econ target & DBT limit
|
Indirect-evap cooling
|
|
Heating airflow VAV/CAV
|
OA econ target reset
|
Direct-evap cooling
|
|
DOAS vent airflow CAV/DCV
|
ER bypass temp target
|
Evap/spray humid per Zn RH
|
|
FCU Cooling airflow CAV/2sp/VAV
|
ER target – cool mode
|
Steam humid per Zn RH
|
|
FCU Heating airflow CAV/2sp/VAV
|
ER target – heat mode
|
|
|
FPB Primary airflow CAV/VAV
|
ER target – PSZ heat-cool
|
|
|
FPB Secondary airflow CAV/2sp/VAV
|
ER bypass temp target -- PSZ
|
|
|
Act bm/IU Primary air CAV/VAV cool
|
Zone mixing variable DBT target
|
|
|
Act bm/IU Primary air CAV/VAV heat
|
Cooling coil – AHU cool LAT
|
|
|
Act beam/IU Induced airflow
|
Cooling coil – AHU dehum LAT
|
|
|
DOAS PTAC/PTHP Cooling airflow CAV/2sp/VAV
|
Cool coil – AHU extend dehum LAT
|
|
|
DOAS PTAC/PTHP Heating airflow CAV/2sp/VAV
|
Cooling coil – AHU supply air DPT
|
|
|
Dual-fan-dual duct zn heat airflow
|
Heating coil – min SAT w reset
|
|
|
PSZ Cooling airflow CAV/2sp/VAV
|
Cooling coil – DOAS tempering
|
|
|
PSZ Heating airflow CAV/2sp/VAV
|
Cooling coil – zone variable LAT
|
|
|
PTAC/PTHP cool airflow CAV/2sp/VAV
|
Cooling coil – full cooling LAT band
|
|
|
PTAC/PTHP heat airflow CAV/2sp/VAV
|
Cooling coil – full dehum LAT band
|
|
|
UCS Cooling airflow
|
Heating coil – full heating LAT band
|
|
|
Cooling-only sys airflow
|
Cooling coil – full h/c LAT band
|
|
|
Heating-only sys airflow
|
Cooling coil – full h/c/dehum LAT
|
|
|
Zone DCV stage1 – VAV ctrl
|
Heating coil – full h/c LAT band
|
|
|
OA min reset - Occupied zone CO2
|
Heating coil – zn fix LAT stage 1
|
|
|
Stratified zn re-mix airflow
|
Heating coil – zn fix LAT stage 2
|
|
|
Wet-bulb Temperature
|
Dewpoint Temperature
|
Percentage Flow
|
|
None <Select>
|
None <Select>
|
None <Select>
|
|
|
|
OA variable min %
|
|
|
|
OA min reset - zone CO2
|
|
|
|
OA min reset - zn VAV flow %
|
|
|
|
OA min reset - Occupied zn VAV%
|
|
|
|
OA min reset - Unocc zn VAV%
|
|
|
|
Zone mixing % primary air
|
|
Heat Transfer
|
Moisture Input
|
Enthalpy
|
|
None <Select>
|
None <Select>
|
None <Select>
|
|
INDEPENDENT TIME SWITCH
| ||
|
Flow Rate
|
Dry-bulb Temperature
|
Relative Humidity
|
|
None <Select>
|
None <Select>
|
None <Select>
|
|
DOAS vent airflow
|
HP/RRcoil/wheel bypass temp
|
Evap/spray humid SA RH
|
|
CAV airflow – occupied hours
|
RA bypass mixed-air target temp
|
Steam humid SA RH
|
|
CAV airflow – nighttime setback
|
Zone mixing fixed DBT damper target
|
|
|
Min fan airflow
|
Pre-heat coil – AHU min EAT
|
|
|
Zone/RA transfer airflow
|
Heating coil – AHU min SAT
|
|
|
Exhaust/CV hood airflow
|
Heating coil – zone variable LAT
|
|
|
Exhaust driven ventilation airflow
|
Heating coil – DOAS tempering
|
|
|
OA min reset - Unocc zone
|
Cooling coil – zone fixed LAT
|
|
|
|
Heating coil – zone fixed LAT
|
|
|
Wet-bulb Temperature
|
Dew-point Temperature
|
Percentage Flow
|
|
None <Select>
|
None <Select>
|
None <Select>
|
|
|
Cooling coil – coil leaving DPT
|
EA% (vs. return or transfer)
|
|
|
|
EA% available to Energy Recovery
|
|
|
|
RA% to alt path or zone
|
|
|
|
OA fixed %
|
|
Heat Transfer
|
Moisture Input
|
Enthalpy
|
|
None <Select>
|
None <Select>
|
None <Select>
|