Parametric tool – Entry pane

The tabs and parameters defined on the configure tabs and columns action appear in the entry pane.
Main dialog – entry pane.
 
The tab shows the tab name and in brackets the number of active parameters. The active parameters are displayed on the tab as columns.
 
In each column each row is a parameter value; select or type-in an entry. The final row in each column is a control that allows the user to add a new row. Each row has a X to delete the row but note that there is no undo feature.
 
It is important to note that the rows relate to each parameter column alone; there is no meaning to rows across parameter columns.
 
Obviously for some parameters reliant on model data, for example weather file, ASP file, constructions, shading scenario etc. the user will need to set-up the required data in the model prior to entering the parametric tool.
 
Table below list the Parametric Tool categories and parameters accessible to the user.
 
 
 
Apply run # to model
 
 
Category
Parameter
 Area of interest
Create new
Override existing
 
Site/Geometry
Location
 Start Page
 
 
x*
* Applies weather file
 
Weather File
APPro
 
 
x
 
 
Building Orientation
ModelIT
 
 
x
 
 
Shading Scenario
Model Browser
 
 
x*
* Applies active shading scheme
 
Windows - Replace Existing Glazing (%)
ModelIT
 
x*
x
* Creates new glazing where not initially drawn
Renewables
Solar Panel Area (m2)
Electricity Generators
 
 
x
 
 
Wind Generator Rated Power (KW)
Electricity Generators
 
 
x*
* User is required to tick on Wind Generator
Envelope
External Wall Construction
APcdb
 
 
x
 
 
Roof Construction
APcdb
 
x
 
 
Ground Floor Construction
APcdb
 
x
 
 
External Window Construction
APcdb
 
x
 
 
Roof Light Construction
APcdb
 
x
 
 
External Window Opening Type
MacroFlo
 
 
x
 
 
Infiltration Max Flow (Individual Air Exchange)
Space Data
 
 
x
 
 
Armstrong Ultima Templok (%)
 ModelIT
 
 
x
 
 
Envelope Template
Building Template Manager
 
 
x
 
 
External Door Construction
APcdb
 
x
 
 
External Window Openable Area Percentage
MacroFlo – Refer to “External Window Opening Type”
 
 
x
 
 
External Window Opening Variation Profile
MacroFlo – Refer to “External Window Opening Type”
 
x
 
 
Internal Celiing/Floor Construction
APcdb
 
x
 
 
Internal Window Construction
APcdb
 
x
 
 
Partition Construction
APcdb
 
x
 
Internal Gains
Lighting Max Sensible Gain and Power Consumption (Individual Gain)
Building Template Manager
 
 
x*
* Based on input mode W/m2 and W (for all lighting types)
 
Lighting Dimming Profile
Building Template Manager
 
x*
* Applied to all lighting types
 
Computers Max Sensible Gain and Power Consumption (Individual Gain)
Building Template Manager
 
x
 
 
Misc Max Sensible Gain and Power Consumption (Individual Gain)
Building Template Manager
 
x
 
 
Cooking Max Sensible and Gain and Power Consumption (Individual Gain)
Building Template Manager
 
x
 
 
Data Centre Max Sensible and Gain and Power Consumption (Individual Gain)
Building Template Manager
 
x
 
 
Lighting Installed Power Density (Individual Gain) (W/m2/(100 lux))
Building Template Manager
 
x*
* Based on input mode Lux (for all lighting types)
 
Machinery Max Sensible and Gain and Power Consumption (Individual Gain)
Building Template Manager
 
x
 
 
Misc Max Latent Gain (Individual Gain)
Building Template Manager
 
x
 
 
People Max Latent Gain (Individual Gain)
Building Template Manager
 
x
 
 
People Max Sensible Gain (Individual Gain)
Building Template Manager
 
x
 
 
People Occupancy (Individual Gain)
Building Template Manager
 
x
 
 
Process Equipment Max Latent Gain (Individual Gain)
Building Template Manager
 
x
 
 
Process Equipment Max Sensible and Gain and Power Consumption (Individual Gain)
Building Template Manager
 
x
 
 
Refrigeration Max Sensible and Gain and Power Consumption (Individual Gain)
Building Template Manager
 
x
 
HVAC
ApacheHVAC File (ASP)
 ApHVAC
 
ApacheSim
 
 
x
 
 
Cooling Setpoint
Space Data
 
 
x
 
 
Heating Setpoint
Space Data – Refer to “Cooling Setpoint”
 
x
 
Space
Cooling Profile
Space Data – Refer to “Cooling Setpoint”
 
x
 
 
Heating Profile
Space Data – Refer to “Cooling Setpoint”
 
x
 
 
Humidity Control Max
Space Data
 
 
x
 
 
Humidity Control Min
Space Data – Refer to “Humidity control Max”
 
x
 
 
Thermal Template
Building Template Manager
 
x*
*
Systems
Aux Vent System
Space Data
 
 
x
 
 
Cooling SSEER
Apache Systems
 
 
x
 
 
DHW System
Space Data – Refer to “Aux Vent System”
 
x
 
 
Heating SCoP
Apache Systems
 
 
x
 
 
HVAC System
Space Data – Refer to “Aux Vent System”
 
x
 
 
System Air Supply Free Cooling Flow
Space Data
 
 
x
 
Ventilation
Auxiliary Max Flow (Individual Air Exchange)
Space Data – Refer to “Natural Max Flow”
 
x
 
 
Natural Max Flow (Individual Air Exchange)
Space Data
 
 
x