Overview

What is the Apache View?
 
The Apache View is a view within the Virtual Environment’s Thermal category.
 
Apache is the name given to the thermal analysis programs in the Virtual Environment. The Apache view provides facilities for:
 
The preparation of thermal input data consists of three main tasks:
 
The interfaces to the thermal analysis programs provide facilities for:
 
Context of ApacheView
To put the Apache view in context, it is useful to examine the steps involved in creating a thermal model and running the thermal analysis programs. This outline is intended as a guide. Many of the steps may be interchanged and data of all types may be edited at any stage.
 
Creation of building geometry
Assignment of Apache thermal data

  1. Select the Thermal Category.
  2. Enter the Apache view
  3. Run the APlocate utility to define site location and weather data (for thermal and solar shading calculations).
  4. Run the utility APcdb to define constructions.
  5. Assign constructions to building elements as appropriate.
  6. Run the utility APpro to define operational profiles.
  7. Define the characteristics of the building’s HVAC systems using Apache Systems and assign systems to spaces.
  8. For each space, assign Space Data to specify heating and cooling, internal gains and ventilation.
  9. Use Space Thermal Templates to facilitate the previous two steps.

 
Assignment of other thermal and solar data
At this stage (or at any suitable time) you may wish to leave the Apache view to carry out the following additional tasks:
 
Thermal analysis and results review

Overview of the ApacheView Interface Features

The Apache view consists of the following interface features:
 
Virtual Environment menu bar
These menus provide functions used throughout the Virtual environment and Apache view.
 
Apache edit toolbar
These icons provide a quick route to functions on the Apache menu bar.
Model workspace
This displays the model geometry and provides a graphical means of selecting geometrical objects.
 
Model view toolbar
This provides functions for manipulating the view of the geometrical model.
 
Model Browser
This list of spaces, opening up to display surfaces and openings in those spaces, provides an alternative way to view and select geometrical objects.
 
Space Group tools
 
These tools allow the creation, application and selection of Space Grouping Schemes. See the ModelIT user guide for further information.
 
Thermal analysis buttons
These buttons invoke the thermal analysis programs CIBSE Loads, ASHRAE Loads and ApacheSim, and Batch Simulation.
 
When the Loads Methodology on the Apache View Settings menu is set to ASHRAE, CIBSE Loads is replaced by ASHRAE Loads.
Common tools for model viewing and interrogation
 
Before using the Apache view you should familiarise yourself with the following tools, which provide the means for navigating around the model to view and set space and building element attributes:
 
In particular, you should be familiar with the following procedures described in the ModelIT User Guide:


Selecting a view of the model workspace using the following buttons on the model view toolbar: