HVAC Network

Enums

class iesve.Ashrae621Version(*values)

Bases: IntEnum


ashrae621_2004 = 0


ashrae621_2007 = 1


ashrae621_2010 = 2


ashrae621_2013 = 3


ashrae621_2016 = 4


ashrae621_2019 = 5


ashrae621_2022 = 6


ashrae621_2025 = 7



class iesve.CoilLocationCircuit(*values)

Bases: IntEnum


primary = 0


secondary = 1



class iesve.CoolingCoilModelType(*values)

Bases: IntEnum


advanced_cooling_coil = 1


simple_cooling_coil = 0



class iesve.DehumidificationControlOption(*values)

Bases: IntEnum


per_system_level_dry_bulb_or_dew_point_control_only = 0


system_supply_air_conditioned_per_zone_relative_humidity_sensors = 1



class iesve.DesignZoneTemperatureSource(*values)

Bases: IntEnum


design_zone_air_temperature = 0


temperature_setpoint = 1



class iesve.ExhaustMakeUpAirOption(*values)

Bases: IntEnum


make_up_air_includes_fixed_percentage_transfer_air = 3


make_up_air_is_hundred_percent_primary_air = 0


make_up_air_is_hundred_percent_transfer_air = 1


transfer_air_makes_up_difference = 2



class iesve.GarageFanControlScheme(*values)

Bases: IntEnum


modulate_airflow = 4


on_continously = 2


on_occupied = 0


on_occupied_plus_extension = 1


reduce_airflow_unoccupied = 3



class iesve.HeatingCoilModelType(*values)

Bases: IntEnum


advanced_heating_coil = 1


simple_heating_coil = 0



class iesve.HeatingSourceSystemType(*values)

Bases: IntEnum


heating_system_aa_heat_pump = 2


heating_system_aa_heat_pump_advanced = 7


heating_system_electric = 5


heating_system_generic = 0


heating_system_heat_transfer_loop = 4


heating_system_hot_water_loop = 1


heating_system_vrf = 6


heating_system_wa_heat_pump = 3



class iesve.HumidificationControlOption(*values)

Bases: IntEnum


per_system_level_relative_humidity_control_only = 0


system_supply_air_humidified_per_zone_relative_humidity_sensors = 1



class iesve.HVACACCCalculationStatus(*values)

Bases: IntEnum


autocalc_complete = 1


autocalc_notposs_error9 = 11


autocalc_notposs_error_unknown = 12


autocalc_ready = 0


autocalc_warning8 = 10


mancalc_complete = 31


mancalc_notposs_error1 = 32


mancalc_notposs_error10 = 41


mancalc_notposs_error2 = 33


mancalc_notposs_error3 = 34


mancalc_notposs_error4 = 35


mancalc_notposs_error5 = 36


mancalc_notposs_error6 = 37


mancalc_notposs_error7 = 38


mancalc_notposs_error8 = 39


mancalc_notposs_error9 = 40


mancalc_notposs_error_unknown = 42


mancalc_ready = 30


notposs_contactfactor = 2


notposs_error1 = 3


notposs_error2 = 4


notposs_error3 = 5


notposs_error4 = 6


notposs_error5 = 7


notposs_error6 = 8


notposs_error7 = 9



class iesve.HVACACCSizingMode(*values)

Bases: IntEnum


autosizing = 0


both = 2


manual = 1



class iesve.HARCAttachedPlant

Bases: object

Heat Acquisition-Rejection Coil (HARC) attached plant type


central_plant_heat_pump = 3


heat_recovery_loop = 2


not_applicable = 0


not_connected = 1



class iesve.HVACBoilerType(*values)

Bases: IntEnum


hot_water_boiler = 1


part_load_curve_boiler = 0



class iesve.HVACChillerType(*values)

Bases: IntEnum


CoolingChiller = 4


DischargeChiller = 3


ElectricAirCooled = 2


ElectricWaterCooled = 1


PartLoadCurve = 0



class iesve.HVACComponentTypes(*values)

Bases: IntEnum


aahp = 31


adiabatic_duct = 22


advanced_heating_coil = 27


air_filter = 51


awhp = 30


boiler = 13


central_plant_heat_pump = 69


chilled_water_loop = 26


chiller = 14


condenser_water_loop = 38


cooling_coil = 25


cooling_tower = 39


damper = 16


dhw_branch = 60


dhw_system_loop = 59


dhw_zone = 61


duct = 8


dx_cooling = 24


eac_chiller = 23


eahp = 62


eahp_cooling_instance = 64


eahp_heating_instance = 63


equip_heat_gain = 9


ewc_chiller = 20


fan = 15


fluid_cooler = 40


generic_cooling_source = 35


generic_heat_source = 29


harc = 70


heat_recov = 10


heat_recovery_hx = 68


heat_recovery_loop = 67


heat_transfer_loop = 33


hot_water_loop = 28


hwb_boiler = 21


hwl_demand_loop = 57


junction = 7


pcm_thermal_battery = 44


plenum = 52


pre_cooling = 41


pump = 45


room = 1


room_chilled_ceiling = 37


room_radiator = 36


simple_cooling_coil = 3


simple_heating_coil = 2


solar_aircollector_bist = 50


solar_water_heater = 32


spray_humidifier = 4


steam_humidifier = 5


temp_flow_control = 6


terminal_recool = 12


terminal_reheat = 11


thermal_storage_loop = 53


thermal_storage_tank = 54


tsc_virtual_chiller = 56


tsd_virtual_chiller = 55


undefined = 0


unitary_cooling = 18


versattemp = 17


vrf_indoor_cool = 47


vrf_indoor_heat = 46


vrf_indoor_type = 48


vrf_outdoor = 49


wahp = 34


water_source_loop = 42


water_water_hx = 43


waterside_econ = 19


zone = 58



class iesve.HVACCoolingSourceSystemType(*values)

Bases: IntEnum


aa_heat_pump_advanced = 7


chilled_water_loop = 0


direct_expansion = 3


generic_cooling_source = 5


legacy = -1


unitary_cooling = 1


variable_refrigerant_flow = 6


water_air_heat_pump = 4


waterside_economizer = 2



class iesve.HVACDefrostControl(*values)

Bases: IntEnum


on_demand = 1


timed = 0



class iesve.HVACDefrostStrategy(*values)

Bases: IntEnum


resistive = 1


reverse_cycle = 0



class iesve.HVACDemandLoopType(*values)

Bases: IntEnum


primary_demand = 0


secondary_demand = 1



class iesve.HVACDHWModel(*values)

Bases: IntEnum


explicit = 0


simple = 1



class iesve.HVACDHWTankDetails(*values)

Bases: IntEnum


heat_loss = 1


insulation_details = 0



class iesve.HVACDHWTankInsulationType(*values)

Bases: IntEnum


factory_insulated = 2


loose_jacket = 1


uninsulated = 0



class iesve.HVACDHWTemperatureSetPointType(*values)

Bases: IntEnum


constant = 0


profile = 1



class iesve.HVACDryFluidCoolerMode(*values)

Bases: IntEnum


dry_mode = 1


dual_mode = 0



class iesve.HVACDXCoolingCondenserType(*values)

Bases: IntEnum


air_cooled = 0


evaporative_cooled = 1


number_of_types = 2



class iesve.HVACDXFanControl(*values)

Bases: IntEnum


one_speed_fan = 0


two_speed_fan = 1


vsd_fan = 2



class iesve.HVACHeatPumpType(*values)

Bases: IntEnum


air_air_heat_pump = 2


air_source_heat_pump = 0


air_water_heat_pump = 1



class iesve.HVACHeatRejectionDevice(*values)

Bases: IntEnum


cooling_tower = 0


dry_fluid_cooler = 1


no_ambient_hr = 2



class iesve.HVACHeatRecoveryModel(*values)

Bases: IntEnum


basic = 0


explicit = 2


percentage_hr = 1



class iesve.HVACLocation(*values)

Bases: IntEnum


duct_contained_within_ra_plenum = 3


duct_contained_within_room = 1


duct_contained_within_sa_plenum = 4


duct_contained_within_void = 2


duct_contained_within_zone = 5


duct_ext_to_building = 0



class iesve.HVACLoopConfiguration(*values)

Bases: IntEnum


primary = 0


primary_secondary = 1



class iesve.HVACLoopSWTResetType(*values)

Bases: IntEnum


coil_based_swt_reset = 4


loop_load_reset = 2


no_reset = 0


not_applicable = 9999


outdoor_air_temp_reset = 1


outdoor_dew_point_reset = 3



class iesve.HVACMultiplexLayerEditingMode(*values)

Bases: IntEnum


all_selected = 1


current = 0



class iesve.HVACNetworkObjectType(*values)

Bases: IntEnum


component = 2


controller = 3


generic = 1


multiplex = 4


not_set = 0


prototype_system = 5


waterside_container = 6



class iesve.HVACOutdoorUnitControl(*values)

Bases: IntEnum


load_priority = 0


load_priority_with_compressor_power = 1


master_thermostat_priority = 3


profile = 5


thermostat_offeset_priority = 4


zone_priority = 2



class iesve.HVACPrototypeSystemType(*values)

Bases: IntEnum


actimass_system = 97


cool_phase_system = 99


prm_system_1 = 1


prm_system_10 = 10


prm_system_2 = 2


prm_system_3 = 3


prm_system_4 = 4


prm_system_5 = 5


prm_system_6 = 6


prm_system_7 = 7


prm_system_8 = 8


prm_system_9 = 9


tata_renew_sc_system = 98



class iesve.HVACRecirculationScheduleType(*values)

Bases: IntEnum


space_occupancy = 0


time_switch_profile = 1



class iesve.HVACSHWPanelType(*values)

Bases: IntEnum


flat_panel = 0


parabolic_panel = 1



class iesve.HVACSysClassification(*values)

Bases: IntEnum


armstrong_templok_system = 18


ecb_2010_compliance_system = 8


ecb_2013_compliance_system = 9


ecb_2016_compliance_system = 16


ecb_2019_compliance_system = 17


iecc_2012_compliance_system = 11


ncm_design_system = 3


necb_2011_compliance_system = 10


necb_2017_compliance_system = 13


no_classification = -1


prm_2004_compliance_system = 4


prm_2007_compliance_system = 5


prm_2010_compliance_system = 6


prm_2013_compliance_system = 7


prm_2016_compliance_system = 12


prm_2019_compliance_system = 14


standard_design_system = 0


t24_design_system = 1


t24_standard_design_system = 2



class iesve.HVACSystemCurveRole(*values)

Bases: IntEnum


AAHPC_FCAPTT = 21


AAHPC_FEIRP = 23


AAHPC_FEIRTT = 22


AAHPH_FCAPT = 17


AAHPH_FDEIRTT = 20


AAHPH_FEIRP = 19


AAHPH_FEIRT = 18


BOIL_FEPT = 4


CHILL_FCAPTT = 0


CHILL_FEIRPT = 2


CHILL_FEIRTT = 1


CPHPC_FCAPTT = 28


CPHPC_FCOPP = 34


CPHPC_FCOPTT = 33


CPHPC_FEIRP = 30


CPHPC_FEIRTT = 29


CPHPH_FCAPTT = 24


CPHPH_FCOPP = 32


CPHPH_FCOPTT = 31


CPHPH_FDEIRTT = 27


CPHPH_FEIRP = 26


CPHPH_FEIRTT = 25


DX_FCAPTT = 8


DX_FEIRP = 10


DX_FEIRTT = 9


EAC_FCAPTT = 5


EAC_FEIRPT = 7


EAC_FEIRTT = 6


PUMP_PWRV = 3


WAHP_FCAPTT_COOL = 14


WAHP_FCAPTT_HEAT = 11


WAHP_FEIRP_COOL = 16


WAHP_FEIRP_HEAT = 13


WAHP_FEIRTT_COOL = 15


WAHP_FEIRTT_HEAT = 12



class iesve.HVACSystemCurveType(*values)

Bases: IntEnum


centrifugal = 0


other = 4


reciprocating = 1


screw = 2


scroll = 3



Bases: IntEnum


ACT_BEAM_IU_INDUCED_AIRFLOW = 2010


ACT_BM_IU_PRIMARY_AIR_CAV_VAV_COOL = 2008


ACT_BM_IU_PRIMARY_AIR_CAV_VAV_COOLING_ONLY = 2108


ACT_BM_IU_PRIMARY_AIR_CAV_VAV_HEAT = 2009


ADJACENT_SPACE_WITH_EA_FAN = 504


AHU_COOLING_COIL = 700


AHU_HEATING_COIL = 601


AHU_PRE_HEAT_COIL = 600


AIRFLOW_ON_IF_NV_INSUF_COOL = 2027


AIRFLOW_ON_IF_NV_INSUF_VENT = 2028


CAV_AIRFLOW_NIGHTTIME_SETBACK = 2020


CAV_AIRFLOW_OCCUPIED_HOURS = 2019


COOLING_AIRFLOW_VAV_CAV = 2000


COOLING_COIL_AHU_COOL_LAT = 2066


COOLING_COIL_AHU_DEHUM_LAT = 2067


COOLING_COIL_AHU_EXTEND_DEHUM_LAT = 2068


COOLING_COIL_AHU_LOWTEMP_LAT = 2099


COOLING_COIL_AHU_SUPPLY_AIR_DPT = 2069


COOLING_COIL_COIL_LEAVING_DPT = 2070


COOLING_COIL_DOAS_DEHUM = 2097


COOLING_COIL_DOAS_FIXED_TEMP = 2096


COOLING_COIL_DOAS_TEMPERING = 2073


COOLING_COIL_FULL_COOLING_LAT_BAND = 2075


COOLING_COIL_FULL_DEHUM_LAT_BAND = 2076


COOLING_COIL_FULL_H_C_DEHUM_LAT = 2079


COOLING_COIL_FULL_H_C_LAT_BAND = 2078


COOLING_COIL_ZONE_FIXED_LAT = 2083


COOLING_COIL_ZONE_VARIABLE_LAT = 2081


COOLING_COIL_ZONE_VARIABLE_LAT_NO_OFFSET = 2100


COOLING_ONLY_SYS_AIRFLOW = 2017


COOLING_THERMOSTAT = 2104


DCV_MIN_OUTSIDE_AIR_ECON = 110


DEDICATED_OA_VENT_COOLING_COIL = 704


DEDICATED_OA_VENT_HEATING_COIL = 606


DELIMITER = -1


DIRECT_ACTING_HEATER_COOLER = 2089


DIRECT_EVAP_COOLING = 2059


DIRECT_EVAP_SPRAY = 1001


DOAS_AHU_COOLING_DEVICE = 800


DOAS_PTAC_PTHP_COOLING_AIRFLOW_CAV_2SP_VAV = 2094


DOAS_PTAC_PTHP_HEATING_AIRFLOW_CAV_2SP_VAV = 2095


DOAS_VENT_AIRFLOW = 2002


DOAS_VENT_AIRFLOW_CAV_DCV = 2003


DUAL_FAN_DUAL_DUCT_ZN_HEAT_AIRFLOW = 2011


DUAL_FAN_DUAL_DUCT_ZONE_COOL_AIRFLOW_AND_OA_VENT = 2107


EA_PERCENT_AVAILABLE_TO_ER = 2032


EA_PERCENT_VS_RETURN_OR_TRANSFER = 2031


ELEC_HEAT_COIL_2ND_STAGE = 605


ENERGY_RECOVERY_BYPASS_DAMPER = 104


ENERGY_RECOVERY_BYPASS_LEGACY_DAMPER = 108


ENERGY_RECOVERY_HX_WHEEL = 900


ENERGY_RECOVERY_HX_WHEEL_COOL_MODE = 902


ENERGY_RECOVERY_HX_WHEEL_HEAT_MODE = 903


ER_BYPASS_TEMP_TARGET = 2047


ER_BYPASS_TEMP_TARGET_LEGACY_CONFIG = 2091


ER_BYPASS_TEMP_TARGET_PSZ = 2051


ER_BYPASS_TEMP_TARGET_PSZ_LEGACY = 2092


ER_TARGET_COOL_MODE = 2048


ER_TARGET_HEAT_MODE = 2049


ER_TARGET_PSZ_HEAT_COOL = 2050


EVAP_SPRAY_HUMID_PER_ZN_RH = 2061


EVAP_SPRAY_HUMID_SA_RH = 2062


EXHAUST_CV_HOOD_AIRFLOW = 2026


EXHAUST_DRIVEN_VENTILATION_AIRFLOW = 2090


EXHAUST_FAN = 203


FCU_ACT_BEAM_COOL_COIL = 701


FCU_ACT_BEAM_HEAT_COIL = 603


FCU_COOLING_AIRFLOW_CAV_2SP_VAV = 2004


FCU_FAN = 204


FCU_HEATING_AIRFLOW_CAV_2SP_VAV = 2005


FILTER_PRESSURE_AND_CHANGE = 300


FPB_FAN = 205


FPB_PRIMARY_AIRFLOW_CAV_VAV = 2006


FPB_SECONDARY_AIRFLOW_CAV_2SP_VAV = 2007


HARC_SYSTEM_EXHAUST_AIR_FLOW_RATE = 1100


HEATED_COOLED_SLAB_ZONE = 505


HEATING_AIRFLOW_VAV_CAV = 2001


HEATING_COIL_AHU_MIN_SAT = 2071


HEATING_COIL_DOAS_TEMPERING = 2074


HEATING_COIL_FULL_HEATING_LAT_BAND = 2077


HEATING_COIL_FULL_H_C_LAT_BAND = 2080


HEATING_COIL_MIN_SAT_WITH_RESET = 2072


HEATING_COIL_ZN_FIX_LAT_STAGE_1 = 2085


HEATING_COIL_ZN_FIX_LAT_STAGE_2 = 2086


HEATING_COIL_ZONE_FIXED_LAT = 2084


HEATING_COIL_ZONE_VARIABLE_LAT = 2082


HEATING_COIL_ZONE_VARIABLE_LAT_NO_OFFSET = 2101


HEATING_ONLY_SYS_AIRFLOW = 2018


HEATING_THERMOSTAT = 2105


HEAT_PIPE_RR_WHL_BYPASS_DAMPER = 105


HEAT_PIPE_RUN_RND_WHEEL = 901


HP_RRCOIL_WHL_BYPASS_TEMP = 2052


HP_RR_WHL_BYPASS_TEMP_DIFF = 2053


INDIRECT_EVAP_COOLING = 2058


INDIRECT_EVAP_SPRAY = 1002


MIN_FAN_AIRFLOW = 2021


MIXED_MODE_DISABLE = 2029


MIXED_MODE_TOUT_TZN_DELTA = 2030


MODULATION_BY_LOAD = 2106


NONE = 0


OA_ECON_DBT_HIGH_LIMIT = 2109


OA_ECON_DIFF_ENTHALPY = 2040


OA_ECON_DPT_LIMIT = 2039


OA_ECON_TARGET_AND_DBT_LIMIT_DEPRECATED = 2034


OA_ECON_TARGET_FULL_COOLING_LAT_BAND = 2110


OA_ECON_TARGET_PER_RA_TEMP = 2093


OA_ECON_TARGET_RESET = 2035


OA_ECON_ZN_TEMP_LOW_LIMIT = 2036


OA_FIXED_PERCENTAGE = 2038


OA_MIN_RESET_OCCUPIED_ZONE_CO2 = 2043


OA_MIN_RESET_OCCUPIED_ZONE_VAV_FLOW_PERCENT = 2045


OA_MIN_RESET_UNOCCUPIED_ZN = 2044


OA_MIN_RESET_UNOCCUPIED_ZN_VAV_FLOW_PERCENT = 2046


OA_MIN_RESET_ZN_VAV_FLOW_PERCENT = 2042


OA_MIN_RESET_ZONE_CO2 = 2041


OA_VARIABLE_MIN_PERCENTAGE = 2037


OCCUPIED_ZONE = 500


ON_IF_TEMP_BELOW_MIN_SAT = 2111


OUTSIDE_AIR_FIXED_MIN_DAMPER = 103


OUTSIDE_AIR_MIN_ECON_DAMPER = 100


OUTSIDE_AIR_NO_MIN_ECON_DAMPER = 101


OUTSIDE_AIR_VARIABLE_MIN_DAMPER = 102


PACKAGE_TERMINAL_UNIT_FAN = 206


PARKING_GARAGE_EXHAUST = 2098


PRE_HEAT_COIL_AHU_MIN_EAT = 2065


PSZ_COOLING_AIRFLOW_CAV_2SP_VAV = 2012


PSZ_HEATING_AIRFLOW_CAV_2SP_VAV = 2013


PTAC_PTHP_COOLING_COIL = 702


PTAC_PTHP_COOL_AIRFLOW_CAV_2SP_VAV = 2014


PTAC_PTHP_COOL_AIRFLOW_CAV_2SP_VAV_NO_OFFSET = 2102


PTAC_PTHP_HEATING_COIL = 604


PTAC_PTHP_HEAT_AIRFLOW_CAV_2SP_VAV = 2015


PTAC_PTHP_HEAT_AIRFLOW_CAV_2SP_VAV_NO_OFFSET = 2103


RAD_CONV_COOL_DEVICE_PANEL = 2088


RAD_CONV_HEAT_DEVICE_PANEL = 2087


RA_BYPASS_MIXED_AIR_TARGET_TEMP = 2054


RA_DUCT_HEAT_LOSS_GAIN = 401


RA_PERCENT_TO_ALT_PATH_OR_ZONE = 2033


RA_PLENUM = 503


RETURN_AIR_DAMPER = 107


RETURN_RELIEF_FAN = 202


SA_DUCT_HEAT_LOSS_GAIN = 400


SA_UFAD_PLENUM = 502


SERIES_FPB_DAMPER = 109


STEAM_HUMIDIFIER = 1000


STEAM_HUMID_PER_ZN_RH = 2063


STEAM_HUMID_SA_RH = 2064


STRATIFIED_ZN_REMIX_AIRFLOW = 2024


SUPPLY_FAN = 200


SUPPLY_FAN_TSP_ADDITION = 201


THERMALLY_STRATIFIED_ZONE = 501


UCS_COOLING_AIRFLOW = 2016


UCS_COOLING_COIL = 703


UNIT_HEATER_FAN = 207


VOID_SPACE = 506


ZONE_AIRFLOW_DETECTION = 2023


ZONE_COOLING_DEVICE = 801


ZONE_DCV_STAGE1_VAV_CTRL = 2022


ZONE_MIXING_BOX_DAMPER = 106


ZONE_MIXING_FIXED_DBT_DAMPER_TARGET = 2057


ZONE_MIXING_PERCENT_PRIMARY_AIR = 2056


ZONE_MIXING_VARIABLE_DBT_TARGET = 2055


ZONE_RA_TRANSFER_AIRFLOW = 2025


ZONE_REHEAT_HEATING_COIL = 602


ZONE_RH_HIGH_LIMIT_FOR_DEC = 2060



class iesve.HVACVRFSourceType(*values)

Bases: IntEnum


air_source = 0


water_source = 1



class iesve.HVACWaterWaterHeatExchangerDataType(*values)

Bases: IntEnum


cooling = 0


heating = 1



class iesve.OccupantDiversity(*values)

Bases: IntEnum


ashrae621_time_averaging = 2


room_data_diversity_factors = 0


specify_independently = 1



class iesve.OutdoorAirRequirementLinkage(*values)

Bases: IntEnum


linked = 0


maximum = 1


sum = 2



class iesve.ProfileVariation(*values)

Bases: IntEnum


constant = 0


profile = 1


relative_to_zone_room = 3


two_values = 2



class iesve.SpaceOutdoorAirRequirementBasis(*values)

Bases: IntEnum


ashrae_170 = 2


ashrae_621 = 0


maximum = 3


outdoor_requirement = 1


sum = 4


title_24 = 5



class iesve.StrategyOutsideAirVentilationMinReq(*values)

Bases: IntEnum


all_hours = 2


occupied_extension_hours = 1


occupied_opening_hours_only = 0



class iesve.StrategySystemFanOperation(*values)

Bases: IntEnum


any_strategy = 3


cycling = 1


off_continously = 2


on_continously = 0



class iesve.SystemConfigurationOptions(*values)

Bases: IntEnum


multi_zone_ahu = 3


multi_zone_doas = 2


package_thermal_unit = 0


single_zone_system = 1



class iesve.SystemOutdoorAirRequirementBasis(*values)

Bases: IntEnum


ashrae_621 = 0


ashrae_621_simplified = 2


sum_of_zone_outdoor_air_requirements = 1



class iesve.SystemSizingBypassOption(*values)

Bases: IntEnum


bypass_system_sizing = 0


system_sizing_on = 1



class iesve.TerminalUnitFanControl(*values)

Bases: IntEnum


constant_fan_control = 0


two_speed_fan_control = 1


variable_fan_control = 2



class iesve.UnitType(*values)

Bases: IntEnum


area_cm2 = 129


area_heating_cooling_power = 127


area_m2 = 10


circulation_loss = 75


condensation = 44


condensation_rate = 43


condensation_rate_kg_m2_second = 117


conductance = 33


conductivity = 30


coordinates = 9


cost_area = 60


crack_flow = 51


degrees = 109


density = 28


dhw_consumption_hour_per_person_uk = 64


dhw_consumption_hour_per_person_us = 65


dhw_consumption_per_hour_us = 98


distance_cm = 2


distance_km = 0


distance_m = 1


distance_mm = 3


electrical_power_area = 35


electrical_power_length = 99


energy_consumption_per_hour = 85


energy_joules = 22


enthalpy = 27


enthalpy_difference = 91


enthalpy_kj = 50


flow_gpm_kbtu_per_hour = 94


flow_litres_per_second_gpm = 86


flow_per_km = 87


flow_per_person = 97


formatting_only = 61


gigajoules_ton_hours = 119


gigajoules_ton_kwh = 120


heat_transfer_coefficient = 32


heatflux_w = 8


heatflux_watts = 66


heatflux_wm2 = 7


heating_cooling_power_area = 39


heating_cooling_power_kw = 36


heating_cooling_power_kw_area = 126


heating_cooling_power_per_person = 13


heating_cooling_power_per_person_short = 14


heating_cooling_power_person = 38


heating_cooling_power_w = 37


heating_cooling_power_w_display_kw = 62


hourly_volumetric_flow = 78


humidity_ratio = 23


inverse_area_m2 = 102


inverse_k = 89


inverse_k2 = 90


inverse_k3 = 95


inverse_length = 80


inverse_per_energy_consumption_kwh = 103


joules_ton_hours = 118


kwh_m2_to_kbtu_ft2 = 101


land_area = 112


land_density = 113


layer_thick = 16


length_m_display_mm = 104


length_m_to_in = 58


line_loss = 69


linear_heat_transfer_coefficient = 93


lumens = 45


luminance = 49


luminous_efficacy_watt = 57


luminous_intensity = 48


luminous_power_density = 56


lux_lumens_m2 = 46


mass_flow = 26


mass_flow_per_hour = 84


mass_kg = 19


mass_kg_per_m = 114


mass_tonne_short_ton = 105


no_conversion = -1


occupancy_density = 41


occupancy_people = 108


occupany_people_per_100_m2 = 121


parts_per_million = 79


percent = 110


pressure = 24


pressure_in_mercury = 52


pressure_in_water = 53


pressure_inches_of_water_column = 116


pressure_velocity_1 = 81


pressure_velocity_2 = 82


pressure_velocity_3 = 83


resistance = 34


sbem_heat_transfer_rate = 96


second_order_heat_loss = 70


solar_flux = 40


specific_fan_power = 63


specific_heat_capacity = 29


speed_metres_per_second = 18


storage_loss_us_gallon = 76


suspended_solid = 128


tank_loss = 68


temperature = 6


temperature_coefficient = 72


temperature_difference_positive = 20


temperature_difference_positive_negative = 21


temperature_half_ip = 130


thermal_capacity_kjm2k = 67


vapour_permeability = 54


vapour_permeance = 55


viscosity = 47


volume_flow = 25


volume_flow_ach = 107


volume_flow_air_changes_per_hour_short = 111


volume_flow_area = 42


volume_flow_equals_supply_air = 123


volume_flow_greater_than_supply_air = 124


volume_flow_m3_per_hour_per_m2_of_envelope = 115


volume_flow_per_unit = 122


volume_flow_percentage_above_supply_air = 125


volume_flow_rate_litres_per_hour_gallon = 74


volume_flow_rate_litres_per_hour_m2 = 71


volume_flow_rate_litres_per_person = 5


volume_flow_rate_litres_per_person_m2 = 15


volume_flow_rate_litres_per_second_m2_facade = 100


volume_flow_rate_m3_per_person = 4


volume_flow_rate_m3_per_person_cfm = 59


volume_litres = 17


volume_litres_per_us_gallons = 77


volume_litres_uk_gallons = 73


volume_m3 = 11


volume_m3_us_gallon = 92


watts_per_flow = 88


wind_speed = 106