SystemParameters

class iesve.SystemParameters

Bases: object


get_schedules() → dict

Get a dictionary of schedules data. Possible dictionary entries:

  • after_hours_operation

  • contaminant_schedule_profile

  • control_scheme

  • design_max_flow_rate

  • exhaust_fan_operation

  • hvac_system_fan_operation_closed_periods

  • hvac_system_fan_operation_occupied_hours_and_extension_periods

  • is_link_operation_and_availability_profiles

  • is_optimal_start

  • minimum_outside_air_ventilation

  • morning_startup_time

  • percent_flow_during_unoccupied_hours

  • system_availability

  • system_availability_schedule

  • system_occupancy_schedule

  • system_operation_schedule

  • zone_recirculation_fan_operation_closed_periods

  • zone_recirculation_fan_operation_occupied_hours_and_extension_periods


get_system_parameters(layer_number: int) → dict

Get dictionary of system parameter data. Possible dictionary entries:

  • air_density_correction_factor

  • autosized_system_air_fan_max_flow_rate

  • basis_for_system_outdoor_air_requirement

  • chilled_water_loop_circuit

  • cooling_coil_model_type

  • cooling_coil_system_type

  • direct_humidification_efficiency

  • energy_recovery_latent_heat

  • energy_recovery_option

  • energy_recovery_power

  • energy_recovery_sensible_heat

  • heat_source_or_loop

  • heating_coil_model_type

  • heating_coil_system_type

  • heating_mode_max

  • indirect_humidification_efficiency

  • is_direct_evaporative_cooling

  • is_energy_recovery_exhaust_air_available

  • is_energy_recovery_used

  • is_indirect_evaporative_cooling

  • is_one_hundred_percent_outside_air_system

  • is_outdoor_air_economizer_dewpoint_temperature_high_limit

  • is_outdoor_air_economizer_differential_enthalpy_limit

  • is_outdoor_air_economizer_drybulb_temperature_high_limit

  • is_outdoor_air_preheat_coil

  • is_system_supply_air_dewpoint_temperature_high_limit

  • is_system_supply_air_relative_humidity_low_limit

  • outdoor_air_economizer_dewpoint_temperature_high_limit

  • outdoor_air_economizer_differential_enthalpy_limit

  • outdoor_air_economizer_drybulb_temperature_high_limit

  • outdoor_air_intake_elevation

  • outdoor_air_preheat_coil

  • override_system_air_fan_autosizing

  • prm_baseline_system_pressure_drop_adjustment

  • reset_system_minimum_outside_air_per_zone

  • system_average_outdoor_air_fraction_cooling

  • system_average_outdoor_air_fraction_heating

  • system_cooling_coil_minimum

  • system_exhaust_airflow_per_zone_requirements

  • system_exhaust_airflow_per_zone_requirements_per_area

  • system_minimum_outdoor_air_intake

  • system_minimum_outdoor_air_intake_make_up

  • system_minimum_outdoor_air_intake_make_up_per_area

  • system_minimum_outdoor_air_intake_per_area

  • system_minimum_sat

  • system_sat_reset

  • system_supply_air_dewpoint_temperature_high_limit

  • system_supply_air_relative_humidity_low_limit

  • system_supply_fan_design_flow_rate

  • system_supply_fan_design_flow_rate_per_area

  • system_supply_fan_minimum_flow

  • system_uncorrected_outdoor_air_requirement

  • system_ventilation_efficiency

  • total_zone_minimum_primary_outside_air_flow_rates

  • ventilation_air_tampering_maximum

  • ventilation_air_tampering_minimum

  • ventilation_design_primary_airflow_cooling

  • ventilation_design_primary_airflow_heating


get_zone_airflow_distribution(layer_number: int) → dict

Get dictionary of zone airflows, turndown & engineering checks data. Possible dictionary entries are:

  • cooling_load_sensible

  • cooling_load_latent

  • heating_load

  • ventilation_pct

  • cooling_airflow_pct

  • cooling_airflow

  • heating_airflow

  • ventilation_airflow


get_zone_airflows_turndown_engineering(layer_number: int) → dict

Get dictionary of zone airflows, turndown & engineering checks data. Possible dictionary entries are:

  • active_beam_induced_air_ratio

  • active_beam_or_induction_unit

  • ashrae_621_voz_air_changes_per_hour

  • ashrae_621_voz_volume_per_area

  • ashrae_621_voz_volume_per_person

  • ashrae_621_voz_volume_per_second

  • constant_volume_cooling_airflow

  • constant_volume_cooling_airflow_per_area

  • constant_volume_heating_airflow

  • constant_volume_heating_airflow_per_area

  • constant_volume_primary_airflow

  • constant_volume_primary_airflow_per_area

  • cooling_design_load

  • cooling_design_load_per_area

  • cooling_design_load_per_area_inversed

  • dcv_co2

  • dcv_min

  • doas_primary_airflow

  • doas_primary_airflow_per_area

  • dynamic_reset_of_system_minimum

  • exhaust_airflow

  • exhaust_airflow_per_area

  • fpb_recirculated_airflow_percentage

  • fpb_recirculated_airflow_percentage_used

  • heating_design_load

  • heating_design_load_per_area

  • heating_design_load_per_area_inversed

  • is_active_beam_layer

  • is_dual_maximum_vav

  • is_force_design_minimum_airflow_at_least_equal_to_required_ventilation_rate

  • is_occupants_served_by_system_derived

  • is_terminal_unit_fan_control

  • is_ventilation_make_up_for_ea

  • manually_specified_target_air_changes_per_hour

  • manually_specified_target_volume_per_second

  • manually_specified_target_volume_per_second_per_area

  • manually_specified_target_volume_per_second_per_person

  • min_primary_supply_airflow

  • min_primary_supply_airflow_per_area

  • minimum_outside_air

  • minimum_outside_air_per_area

  • minimum_outside_air_per_person

  • minimum_primary_airflow

  • minimum_primary_airflow_or_vav_turndown

  • minimum_primary_airflow_per_area

  • minimum_primary_airflow_turndown

  • minimum_primary_airflow_turndown_per_area

  • occupant_density

  • occupant_number

  • occupants_served_by_system

  • outdoor_air_requirement_at_max_supply_airflow

  • outdoor_air_requirement_at_minimum_supply_airflow

  • recirculated_secondary_airflow_max

  • recirculated_secondary_airflow_max_per_area

  • recirculated_secondary_airflow_minimum

  • recirculated_secondary_airflow_minimum_per_area

  • required_make_up_air_changes_per_hour

  • required_make_up_volume_per_second

  • required_make_up_volume_per_second_per_area

  • required_make_up_volume_per_second_per_person

  • required_min_air_changes_per_hour

  • required_min_volume_per_person

  • required_min_volume_per_second

  • required_min_volume_per_second_per_area

  • requirement_as_percent_max_cooling_airflow

  • requirement_as_percent_max_heating_airflow

  • requirement_as_percent_minimum_airflow

  • return_at_max_ea_min_airflow

  • return_at_max_ea_min_airflow_per_area

  • system_exhaust_airflow

  • system_exhaust_airflow_per_area

  • system_ventilation_efficiency

  • terminal_fan_unit_control

  • total_floor_area_served

  • total_volume_served

  • transfer_at_max_ea_min_airflow

  • transfer_at_max_ea_min_airflow_per_area

  • zone_floor_area

  • zone_ventilation_max_total_required_air_changes_per_hour

  • zone_ventilation_max_total_required_air_changes_per_second_per_person

  • zone_ventilation_max_total_required_volume_per_second

  • zone_ventilation_max_total_required_volume_per_second_per_area

  • zone_volume


get_zone_loads_airflows(layer_number: int) → dict

Get dictionary of zone loads & supply airflows data. Possible dictionary entries:

  • airside_cooling_load_after_room_contribution

  • airside_heating_load_after_room_contribution

  • cooling_adjusted_sat

  • cooling_airflow_required_latent

  • cooling_airflow_required_latent_per_area

  • cooling_design_load_oversizing_factor

  • cooling_design_loads_with_oversizing_latent

  • cooling_design_loads_with_oversizing_sensible

  • cooling_design_max_airflow

  • cooling_design_max_airflow_per_area

  • cooling_design_supply_air_temperature

  • cooling_design_supply_delta_t

  • cooling_design_temperature_for_airflow

  • cooling_design_temperature_gain_for_airflow_sizing_used

  • cooling_design_temperature_source

  • cooling_design_zone_load_latent

  • cooling_design_zone_load_sensible

  • cooling_load_for_terminal_unit

  • cooling_max_airflow_for_terminal_unit

  • cooling_max_airflow_for_terminal_unit_per_area

  • cooling_system_minimum_sat_used

  • dual_maximum_vav

  • heating_adjusted_sat

  • heating_design_load_oversizing_factor

  • heating_design_loads_with_oversizing

  • heating_design_max_airflow

  • heating_design_max_airflow_per_area

  • heating_design_supply_air_temperature

  • heating_design_supply_delta_t

  • heating_design_temperature_for_airflow

  • heating_design_temperature_gain_for_airflow_sizing_used

  • heating_design_temperature_source

  • heating_design_zone_load

  • heating_load_for_terminal_unit

  • heating_max_airflow_for_terminal_unit

  • heating_max_airflow_for_terminal_unit_per_area

  • heating_system_minimum_sat_used

  • is_adjust_cooling_airflow

  • is_adjust_heating_airflow

  • is_allow_cooling_undersized

  • is_allow_heating_undersized

  • is_cooling_design_max_airflow_derived

  • is_force_cooling_at_least_equal_to_ventilation_rate

  • is_force_cooling_to_maintain_relative_humidity_setpoint

  • is_force_heating_at_least_equal_to_ventilation_rate

  • is_heating_design_max_airflow_derived

  • percent_of_sat

  • percent_of_sat_for_airflow_sizing_used

  • percent_sensible_cooling_load

  • percent_sensible_heating_load

  • transfer_air_contribution_cooling

  • transfer_air_contribution_heating


get_zone_temperature_humidity_equipment(layer_number: int) → dict

Get dictionary of zone temperature, humidity and equipment data. Possible dictionary entries:

  • chilled_water_loop_circuit

  • cooling_availability_schedule_profile_id

  • cooling_coil_leaving_air_temperature

  • cooling_coil_model_type

  • cooling_coil_system_type

  • cooling_control_throttling_range

  • cooling_design_supply_air_temperature

  • cooling_design_zone_air_temperature

  • cooling_setback_setpoint

  • cooling_setpoint

  • cooling_setpoint_operation_schedule_used

  • cooling_setpoint_switching_schedule_profile_id

  • cooling_setpoint_variation

  • cooling_source

  • cooling_system_operation_schedule_used

  • cooling_thermostat_temp_setpoint_used

  • dehumidification

  • heating_availability_schedule_profile_id

  • heating_coil_leaving_air_temperature

  • heating_coil_model_type

  • heating_coil_system_type

  • heating_control_throttling_range

  • heating_design_supply_air_temperature

  • heating_design_zone_air_temperature

  • heating_setback_setpoint

  • heating_setpoint

  • heating_setpoint_operation_schedule_used

  • heating_setpoint_switching_schedule_profile_id

  • heating_setpoint_variation

  • heating_source

  • heating_system_operation_schedule_used

  • heating_thermostat_temp_setpoint_used

  • humidification

  • is_force_cooling_airflow

  • is_high_limit_only_when_outside_air_ventilation_engaged

  • is_update_space_data

  • system_level_cooling_equipment_used

  • system_level_heating_equipment_used

  • thermal_template

  • zone_relative_humidity_high_limit

  • zone_relative_humidity_low_limit

  • zone_rh_high_limit_evaporated_cooling


get_zone_ventilation_exhaust(layer_number: int) → dict

Get dictionary of zone ventilation & exhaust data. Possible dictionary entries:

  • 621_default_occupancy_per_are

  • 621_default_occupancy_used

  • 621_occupancy

  • air_class

  • ashrae_170_function_category

  • ashrae_170_function_category_str

  • ashrae_170_table

  • ashrae_170_version

  • ashrae_621_version

  • basis_for_zone_outside_air_requirement

  • breathing_zone

  • breathing_zone_per_area

  • cooling_air_distribution_effectiveness

  • cooling_discharge_airflow

  • cooling_discharge_outdoor_air_fraction

  • cooling_percent_max_primary_airflow

  • cooling_system_fraction_zone_recirculated_air

  • cooling_zone_outdoor_airflow

  • cooling_zone_outdoor_airflow_per_area

  • cooling_zone_primary_air_fraction_of_total_discharge

  • cooling_zone_primary_airflow

  • cooling_zone_primary_airflow_pc_voz

  • cooling_zone_primary_airflow_outdoor_air_fraction

  • cooling_zone_ventilation_efficiency

  • dcv_co2_band_maximum

  • dcv_co2_band_minimum

  • dcv_minimum_when_occupied_volume_per_second

  • dcv_minimum_when_occupied_volume_per_second_per_area

  • dcv_reduction_when_unoccupied_used

  • dcv_via_sensors_used

  • exhaust_air_change_requirement

  • exhaust_air_change_requirement_air_changes_per_hour

  • exhaust_air_change_requirement_data

  • exhaust_air_change_requirement_unit

  • exhaust_air_change_requirement_used

  • exhaust_air_change_requirement_volume_per_second

  • exhaust_air_change_requirement_volume_per_second_per_person

  • exhaust_air_change_requirement_volume_per_second_per_square_area

  • exhaust_air_change_requirement_volume_per_second_per_unit

  • exhaust_air_occupancy_id

  • exhaust_air_occupancy_units

  • exhaust_air_occupancy_used

  • exhaust_airflow

  • exhaust_airflow_adjacent_space

  • force_zone_exhaust_used

  • force_zone_outside_air_used

  • heating_air_distribution_effectiveness

  • heating_discharge_airflow

  • heating_discharge_outdoor_air_fraction

  • heating_percent_max_primary_airflow

  • heating_system_fraction_zone_recirculated_air

  • heating_zone_outdoor_airflow

  • heating_zone_outdoor_airflow_per_area

  • heating_zone_primary_air_fraction_of_total_discharge

  • heating_zone_primary_airflow

  • heating_zone_primary_airflow_pc_voz

  • heating_zone_primary_airflow_outdoor_air_fraction

  • heating_zone_ventilation_efficiency

  • is_dcv

  • is_dcv_force_vav_fully_open

  • is_percent_cooling_max_primary_airflow

  • is_percent_heating_max_primary_airflow

  • is_zone_supply_one_hundred_percent_transfer_air

  • make_up_air_option

  • make_up_air_transfer_percentage

  • min_oa_airflow_ach

  • min_oa_airflow

  • min_total_air_ach

  • min_total_airflow

  • occupancy_category

  • occupancy_category_str

  • occupant_diversity

  • occupant_diversity_factor

  • outdoor_air_change_percent_requirement_volume

  • outdoor_air_change_requirement_air_changes_per_hour

  • outdoor_air_change_requirement_link

  • outdoor_air_change_requirement_total_volume_per_second

  • outdoor_air_change_requirement_used

  • outdoor_air_change_requirement_volume

  • outdoor_air_change_requirement_volume_per_second_per_area

  • outdoor_air_change_requirement_volume_per_second_per_person

  • pressurization

  • primary_air_change_requirement

  • primary_air_change_requirement_air_changes_per_hour

  • primary_air_change_requirement_used

  • primary_air_change_requirement_volume_per_second

  • primary_air_change_requirement_volume_per_second_per_area

  • primary_air_change_requirement_volume_per_second_per_person

  • supply_air_transfer

  • supply_air_transfer_used

  • transfer_air_volume

  • transfer_airflow_rate

  • ventilation_coefficient_ra

  • ventilation_coefficient_rp

  • ventilation_increase

  • ventilation_max_requirement

  • ventilation_requirement