Bases: HVACAbstractComponent
Dictionary of design condition outdoor unit data. Possible dictionary entries are:
cooling_capacity
cooling_cop
cooling_combination_ratio
cooling_average_indoor_wb_temperature
cooling_outdoor_db_temperature
heating_capacity
heating_cop
heating_combination_ratio
heating_average_indoor_db_temperature
heating_average_indoor_wb_temperature
heating_outdoor_wb_temperature
heating_outdoor_db_temperature
cooling_entering_source_loop_temperature
heating_entering_source_loop_temperature
Dictionary of design parameters. Possible dictionary entries are:
performance_curve_set_description, performance_curve_set_name, is_autosize_outdoor_unit, oversizing_factor
Dictionary of reference indoor unit data. Possible dictionary entries are:
cooling_entering_coil_wb_temperature
cooling_outdoor_air_db_temperature
use_same_cooling_temperature_as_outdoor
heating_entering_coil_db_temperature
heating_outdoor_air_wb_temperature
use_same_heating_temperature_as_outdoor
cooling_entering_water_temperature
heating_entering_water_temperature
Dictionary of reference condition outdoor unit data. Possible dictionary entries are:
cooling_capacity
cooling_cop
cooling_combination_ratio
cooling_average_indoor_wb_temperature
cooling_outdoor_db_temperature
use_same_cooling_temperature_as_indoor
heating_capacity
heating_cop
heating_combination_ratio
heating_average_indoor_db_temperature
heating_average_indoor_wb_temperature
heating_outdoor_wb_temperature
heating_outdoor_db_temperature
use_same_heating_temperature_as_indoor
cooling_entering_source_loop_temperature
heating_entering_source_loop_temperature
Dictionary of VRF System data. Possible dictionary entries are:
unit_control_profile
source_type
min_part_load_ratio
unit_control
source_water_loop_id
master_thermostat_location_space_id
heat_recovery_mode
is_seperate_piping_values
equivalent_piping_length_cooling
equivalent_piping_length_heating
piping_level_difference_cooling
piping_level_difference_heating
use_crankcase_heater
crankcase_heater_power
max_outdoor_temp_for_crankcase_heater_operation
use_electric_resistance_backup_heat
backup_cooling_source_cop
backup_heating_source_efficiency
outdoor_temp_operation_range_cooling_minimum
outdoor_temp_operation_range_cooling_maximum
outdoor_temp_operation_range_heating_minimum
outdoor_temp_operation_range_heating_maximum
fan_eir
defrost_strategy
resistive_defrost_heater_capacity
defrost_control
defrost_time_fraction
max_outdoor_temp_for_defrost_operation
cooling_heating_meter
crankcase_heater_meter
electric_resistance_backup_heat_meter
backup_cooling_source_meter
backup_heating_source_meter
fan_meter
defrost_meter