The user should ensure they have entered space comfort settings on the space template or space data and if there are more than one system type assigned to target spaces ensure these are identified in room groups.
The user should ensure they have run a thermal simulation with a 10-minute reporting timestep.
Open VistaPro and select the appropriate results file (*.aps) from the results file section.
Select the target spaces from the browser or if there are more than one system type select the target spaces for one system type. This can be done more conveniently using room groups.
Click on the Comfort Analysis toolbar button

. The Comfort analysis dialog will appear where the user should make sure the BB101:2018 option is selected, and options picked.
To run the analysis and generate the report click on ‘Create report for current selection set’.
The report is saved in the Vista folder of your project folder.