aux_vent_system
|
(string) Aux vent system ID
|
|
aux_vent_system_same
|
(Bool) True if aux vent system is same as HVAC system
|
|
cooling_capacity_units
|
(int) see below
|
|
cooling_capacity_unlimited
|
(Bool)
|
|
cooling_capacity_value
|
(float) see cooling_capacity_units for units
|
|
cooling_plant_radiant_fraction
|
(float)
|
|
dhw_system
|
(string) DHW System ID
|
|
dhw_system_same
|
(Bool) True if DHW system is same as HVAC system
|
|
heating_capacity_units
|
(int) see below
|
|
heating_capacity_unlimited
|
(Bool)
|
|
heating_capacity_value
|
(float) see cooling_capacity_units for units
|
|
heating_plant_radiant_fraction
|
(float)
|
|
HVAC_system
|
(string) HVAC System ID
|
|
system_air_free_cooling
|
(float) see system_air_free_cooling_units for units
|
|
system_air_free_cooling_units
|
(int) see below for airflow units
|
|
system_air_minimum_flowrate
|
(float) see system_air_minimum_flowrate_units for units
|
|
system_air_minimum_flowrate_units
|
(int) see below for airflow units
|
|
system_air_variation_profile
|
(string) System air variation profile ID
|
|
cooling_profile
|
(string) profile ID
|
|
cooling_setpoint
|
(float, °C) cooling setpoint, only valid if cooling_setpoint_type is constant
|
|
cooling_setpoint_profile
|
(string) only valid if cooling_setpoint_constant is False
|
|
cooling_setpoint_twovalue_main_setpoint
|
(float, °C) Two-value main setpoint
|
|
cooling_setpoint_twovalue_profile
|
(string) Two-value profile ID
|
|
cooling_setpoint_twovalue_setback
|
(float, °C) Two-value setback setpoint
|
|
cooling_setpoint_type
| |
|
dhw
|
(float) DHW value linked to dhw_units
|
|
dhw_profile
|
(string) '–' if linked to occupancy, else profile ID of DHW profile
|
|
dhw_units
|
(string) one of: l/(h·pers) or l/h
|
|
heating_profile
|
(string), profile ID
|
|
heating_setpoint
|
(float, °C) cooling setpoint, only valid if heating_setpoint_type is True
|
|
heating_setpoint_profile
|
(string) only valid if heating_setpoint_constant is False
|
|
heating_setpoint_twovalue_main_setpoint
|
(float, °C) Two-value main setpoint
|
|
heating_setpoint_twovalue_profile
|
(string) Two-value profile ID
|
|
heating_setpoint_twovalue_setback
|
(float, °C) Two-value setback setpoint
|
|
heating_setpoint_type
| |
|
plant_profile
|
(string) profile ID
|
|
plant_profile_type
|
(int) 0 = heating Profile, 1 = cooling profile, 2 = independent profile
|
|
sat_perc_lower
|
(float, %)
|
|
sat_perc_upper
|
(float, %)
|
|
aux_vent_system
|
|
aux_vent_system_same
|
|
conditioned
|
|
cooling_capacity_units
|
|
cooling_capacity_value
|
|
cooling_plant_radiant_fraction
|
|
dhw_system
|
|
dhw_system_same
|
|
heating_capacity_units
|
|
heating_capacity_value
|
|
heating_plant_radiant_fraction
|
|
HVAC_methodology
|
|
HVAC_system
|
|
system_air_free_cooling
|
|
system_air_free_cooling_units
|
|
system_air_minimum_flowrate
|
|
system_air_minimum_flowrate_units
|
|
system_air_variation_profile
|
|
cooling_profile
|
|
cooling_setpoint
|
|
cooling_setpoint_profile
|
|
cooling_setpoint_twovalue_main_setpoint
|
|
cooling_setpoint_twovalue_profile
|
|
cooling_setpoint_twovalue_setback
|
|
cooling_setpoint_typeconstant
|
|
dhw
|
|
dhw_profile
|
|
dhw_units
|
|
heating_profile
|
|
heating_setpoint
|
|
heating_setpoint_constant
|
|
heating_setpoint_twovalue_main_setpoint
|
|
heating_setpoint_twovalue_profile
|
|
heating_setpoint_twovalue_setback
|
|
heating_setpoint_typeprofile
|
|
plant_profile
|
|
plant_profile_type
|
|
sat_perc_lower
|
|
sat_perc_upper
|