Fundamentals of Part L2 (2021)

New Part L2 regulations came into force in England on June 15th 2022 (29th March 2023 for Wales) and apply to non-domestic buildings beginning construction after this date. The regulations require designers to demonstrate further reductions in carbon emissions from building energy use relative to the standards set by the previous editions of the regulations. This is achieved by performing a detailed analysis of the carbon emissions of two buildings:
The analysis of carbon emissions must be performed with accredited software applying the National Calculation Methodology (NCM), implemented in a DSM method such as ApacheSim or BRE’s SBEM program (driven by either the native iSBEM interface or a proprietary interface such as VE-SBEM).
The actual building’s performance must improve on that of the notional building.
Assessments must be performed under standard occupancy and plant operating conditions. This means that under the new regulations, some of the data entered by the user to model the building for design work has to be replaced by different data for the purpose of compliance analysis.
It should be remembered that Part L2 places the requirement for standard occupancy and plant operating conditions on a model. The consequence of this is that, in addition to the actual and notional buildings, the designer will usually need to model and analyse (for design and other non-regulations purposes) a third building:
 
The real building is the building presented in the Apache View, where the special conditions required for NCM analyses are not applied.
 
The testing of carbon emissions constitutes regulations 24, 25, 25B, 26, 26C, 27 and 27C of Part L2 as follows:
 
  1. The building meets the target emission rate required under regulation 26.
  2. Both: i. An analysis is made of the technical, environmental and economic feasibility of using high efficiency alternative systems, which include decentralised energy supply systems based on energy from renewable sources.
ii. This analysis is considered as required by regulation 25A.
  1. Target primary energy rate.
  2. Target emission rate.
Section 2 of this approved document sets out how to produce these calculations.
This testing is also subject to:
 
Users of the VE Compliance software are strongly advised to study the official documents defining the regulations.