SunCast Features

SunCast can be used at any stage of the design process to perform shading and solar insolation studies.
 
SunCast is required to run solar shading calculations to generate numerical output, which can be viewed directly in SunCast, or exported as tables to include in reports, either for the whole model or a selected surface. These calculations can then be applied to simulations via the SunCast link on apache simulation options, to improve accuracy linked to solar shading.
 
SunCast can also carry-out sunlight exposure assessments and generate shading images and animations quickly and easily from a model in ModelIT, or show Solar Energy or Solar Exposure across the external surfaces of the model.
 
SunCast can be used to investigate:
 
SunCast generates shadows and internal solar insolation from any sun position defined by date, time, orientation, site latitude and longitude. Three shading file types can be generated:
     The .shd file is usable in Suncast and Apache.
     The .she file is usable in Suncast only.
     The .shs file is usable in Suncast only.
 
This shading information can be stored for subsequent analysis by:
 
SunCast can be used in a variety of studies including passive solar design and is essential at the planning stage to visualize the shading impact of the building on surrounding buildings. SunCast has also been used to study problems such as grass growth in sports stadia and right to light issues. In addition, because it is possible to remove surfaces to investigate solar penetration, SunCast can be used to investigate internal design issues from office layouts to positioning of art in museums.
 
 
Sunlight exposure assessments
SunCast offers three tools for solar exposure assessments. Which tool to use is dependent on the required end-use:
 
Three options are provided:

This results shown in the flex grid display:
At model level (no surface selected) solar & cloud data for each month / hour is shown in the Flex-grid.
 
The Simulation options > Sunlight exposure settings allow the user to define the type of sensor utilised for the exposure to sunlight calculations: plane, centroid or BR209 (centre of the opening width and at least 1.2 m above the floor and 0.3 m above the sill).
 
Surrounding obstructions, window reveals and balconies or overhangs above the window affect exposure to sunlight and should be considered.
 
The Solar energy analysis tool uses SunCast and Apache to generate hourly solar shading and external incident solar flux data from the weather file for a design day per month (15th) which is then used to produce surface energy results in kWh or kWh/m² for the specified period for purposes such as photovoltaic assessments. 
 
Surrounding obstructions, window reveals and balconies or overhangs above the window affect solar shading and should be considered. The tool displays the results as false colour output on the model surfaces in MV2.
 
The Solar exposure analysis tool uses SunCast’s generated hourly solar shading data (so no weather file data) for a design day per month (15th) to produce surface exposure results in hours and percentage of available hours for the specified period for design purposes such as photovoltaic shadowing passive solar access, landscaping sun access, external comfort. 
 
Surrounding obstructions, window reveals and balconies or overhangs above the window affect access to sun and should be considered. The tool displays the results as false colour output on the model surfaces in MV2.