A
Rotate selected object(s) by angle (degrees).
Parameters:
angle
Example:
 
a=45
 
ADJHOLE
Make adjacent surfaces Holes
Example:
 
adjhole
 
AXON
Set axonometric view rotation (no parameters = display current azi, alt)
Parameters:
<none>
 or
azimuth, altitude
Example:
 
axon=120,35
 
BUILD
Regenerate adjacencies for selected space(s)
Example:
 
build
 
BYPASSCHECK
Bypass geoemtry checks
Parameters:
ON/OFF
Example:
 
bypasscheck=on
 
C
Closes current shape
Example:
 
c
 
CELLS
Convert selected body's surfaces to 1m² cells.  Works on a single selected space at model level.
Example:
 
cells
 
CLIPOPENINGS
Ensures openings do not extend beyond adjacency they are on
Example:
 
clipopenings
 
COL
Set Color For Selected Spaces
Parameters:
ColorIndex
Example:
 
COL=5
 
CORE
Creates perimeter and core zoning of the current space
 
Notes:
 
Parameters:
Perimeter depth (in metres)
 
Example:
 
core=6
 
 
 
CORRECTSHELL
Attempt to heal an unclosed shell
Example:
 
correctshell
 
D
Dragging direction/distance  for dragface tool or opening resize
Parameters:
offset
Example:
 
d=-2.4
 
DEL
delete the selected space(s)
Example:
 
del
 
DELCOMPS
Delete all placed components from currently selected spaces
Example:
 
delcomps
 
DELMV
Deletes model variants (Caution must be used as important variants can be lost e.g. proposed and baseline models for PRM)
Example:
 
delmv
 
DELSURF
Removes selected surface from space
Example:
 
delsurf
 
DIM
Show dimensions while drawing space
Parameters:
ON/OFF
Example:
 
dim=off
 
DUMPCOMPS
Dump component geometry (placed components) into a GEM file
Example:
 
dumpcomps
 
DUMPNM
Export the UK NCM Notional Model to GEM file
Example:
 
dumpnm
 
DUMPRM
Export the UK NCM Reference Model to a GEM file.
Example:
 
dumprm
 
DV
Depth of view - set view limits from h1 to h2
Parameters:
h1,h2
Example:
 
dv=3.25,7.8
 
DX
Set relative position from current position by x and y offset.
Or… set displacement to (dx,dy) in move or copy
 
* In Window/Door/Hole mode set first co-ordinate relative to bottom left corner, then width, height (rectangular mode)
Parameters:
x,y                  
Example:
 
dx=20, 10
 
DXF
Show DXF layers window
Example:
 
dxf
 
DXFNAMES
Get space names from DXF file
Example:
 
dxfnames
 
FIND
select space by the referenced ID
Parameters:
roomid
Example:
 
find=room0001
 
FIX
Rounds vertices to a given number of decimal places for selected room(s). Range = 3-6.
Parameters:
precision
Example:
 
fix=6
 
G
Define % glazing for selected space
Parameters:
glazing area
Example:
 
g=50
 
GW
Define % glazing to Walls only
Parameters:
glazing area
Example:
 
g=25
 
INITZONES
Initialises zone lists (obsolete)
Example:
 
initzones
 
INN
Toggle inner-volumes on/off
Parameters:
ON/OFF
Example:
 
inn=off
 
INT
Switch intersection check on or off depending on param
Parameters:
ON/OFF
Example:
 
INT=OFF
 
INTBODY
key-in for intersection check on selected spaces
Example:
 
intbody
 
INTERSECTION
Switch intersection check on or off depending on param
Parameters:
ON/OFF
Example:
 
intersection=on
 
LAY
Set Layer For Selected Spaces
Parameters:
LayerIndex
Example:
 
LAY=2
 
LISTCOMPS
List component geometry (placed components) into a text file which is viewed
Example:
 
listcomps
 
MB
set Model Browser switch
Parameters:
on/off
Example:
 
mb=on
 
MIT
Merge another ModelIT project into this one
Example:
 
mit
 
MODEL
key-in option to perform model consistency check
Example:
 
model
 
OPEN
Set Openings to new type (i.e. convert Windows to Holes)
IW/ID/IH are only required for model level conversion
Parameters:
W/D/H/IW/ID/IH
where:
W = Window
D = Door
H = Hole
IW = Internal Window
ID = Internal Door
IH = Internal Hole
Example:
 
open=w
 
ORIGIN
Centres the model on the grid origin (0,0).
 
Notes:
Parameters (optional):
x/y/z
Example:
 
origin
OSM
Imports map data from OpenStreetMap and automatically creates geometry.
 
Notes:
Example:
 
osm
 
            Let’s grab a corner of Central Park in New York City, NY, USA.
 
Once imported to the VE…
 
 
And using the model viewer…
P
Set polar position.
Parameters:
x,y
Example:
 
P=4,5
 
 
Path
Define a follow-me path to create geometry.  Requires at SECTION to have been created first.
See Extrude along a path for more detail.
Example:
 
PATH
PSWIN
Place simple openings tool.  Used in PLAN view to add windows and doors on to model.  Commonly used when tracing over a DXF drawing.
See Draw simple openings in plan view for more detail.
 
Example:
 
PATH
 
REBUILD
Rebuild model adjacencies
Example:
 
rebuild
 
RECALC_PV_AREAS
Recalculates the PV panel area sizes for all PV panels in the active model
Example:
 
recalc_pv_areas
 
RENAME
Rename the selected rooms. 
 
For more detail please see here.
Example:
 
rename
 
RG
Set space group for selected spaces (browser may not refresh automatically)
Parameters:
group index
Example:
 
rg=3
 
RMD
Remove doors
Example:
 
rmd
 
RMDE
Remove doors (external)
Example:
 
rmde
 
RMDI
Remove doors (internal)
Example:
 
rmdi
 
RMH
Remove holes
Example:
 
rmh
 
RMHE
Remove holes (external)
Example:
 
rmhe
 
RMHI
Remove holes (internal)
Example:
 
rmhi
 
RMOPEN
remove all openings of area <= openingArea
Parameters:
openingArea
Example:
 
RMOPEN=5.5
removes all openings of 5.5m or less
ROOM
key-in for Geometry Type. Range 1-4.
Parameters:
1/2/3/4
Example:
 
room=2  
sets room to be adjacent building
SECTION
Create a section for use with the path tool.
See Extrude along a path for more detail.
Example:
 
section
 
SELCOL
Select all spaces with current colour
Example:
 
selcol
 
SELLAY
Select all spaces on current layer
Example:
 
sellay
 
SHELL
Create a single outline shell from all model spaces.
WARNING: all assignments and openings will be lost – treat with care!
Example:
 
shell
 
SHRINK
Opens the following dialog window which allows you to scale the currently selected openings by either as set dimension or by a percentage.
See Scale selected openings for more detail.
Example:
 
shrink
SPLIT
separate connected spaces
Example:
 
split
 
STAMP
Create an opening stamp from the selected openings.  Must be done at opening level.  Once stamp has been created it can be pasted anywhere in the model using the “Stamp” option in the openings drop-list.
See Opening stamp tool for more detail.
Example:
 
stamp
 
 
TEXT
Show/Hide text on model view. Currently shows ID, name, volume and floor area.
Parameters:
ON/OFF
Example:
 
text=on
 
TIDY
Scan selected body to remove colinear vertices, merge coplanar surfaces and find unmatched edges creating polygons to fill gaps
Example:
 
tidy
 
Tidymirror
 
Looks at the selected space, and detects surfaces which lie in the same plane, but face in opposite directions (are mirrors of each other). It clips them in relation to other polygons, and then deletes any remaining pairs of mirrored faces facing in opposing directions.
These forms of surfaces are usually present in gbXML where there are offshoot floating surfaces outside a space volume, and are effectively a mirror image of each other.
Example:
 
tidymirror
 
 
Tidysurfs
Calls “tidyunbound” and then “tidymirror”.
Example:
 
tidysurfs
 
Tidyunbound
Looks at a selected space, detects any surfaces with disconnected edges, and removes the ‘unbound’ surfaces because any disconnected surfaces cannot be part of a volumetrically bound shell.
Useful to tidy up some of the more fractured spaces that can come from external geometry files.
Example:
 
tidyunbound
 
 
TOOLOFF
Hides all ModelIT toolbars other than the key-in toolbar.
Example:
 
tooloff
 
TOOLON
Shows all ModelIT toolbars that were chosen in preferences.
Example:
 
toolon
 
TOOLRESET
Reset toolbars to default (all visible)
Example:
 
toolreset
 
UNDO
Add option to switch off the undo operation in order to speed up response
Parameters:
ON/OFF
Example:
 
undo=on
 
UNITS
key-in option to change the model measurement units i.e. metric (SI) or InchPound(IP).
Parameters:
IP/METRIC
Example:
 
units=metric
 
VIEWINIT
Set view initialisation to be either late or early (defunct)
Parameters:
LATE/EARLY
Example:
viewinit=late
 
VIS
toggle visibility of selected space(s)
Parameters:
ON/OFF
Example:
 
vis=on
 
VP
set Viewport switch (defunct?)
Parameters:
on/off
Example:
 
vp=on
 
X
set the current co-ordinate to be the absolute postion x,y
Parameters:
x,y
Example:
 
X=20,4
 
XMLDUMP
Exports Templates, ApacheSystems and Constructions to XML files (not complete)
Example:
 
xmldump
 
ZONEID
Toggle to redraw Browser with "ID" rather than "Name" (& vice versa)
Example:
 
zoneid