×
Menu
Index

6.1.7.9.1 Methods Defined Here

 
get_schedules() -> dictionary
Get a dictionary of schedules data.
Possible dictionary entries:
 
after_hours_operation
contaminant_schedule_profile
control_scheme
design_max_flow_rate
exhaust_fan_operation
hvac_system_fan_operation_closed_periods
hvac_system_fan_operation_occupied_hours_and_extension_periods
is_link_operation_and_availability_profiles
is_optimal_start
minimum_outside_air_ventilation
morning_startup_time
percent_flow_during_unoccupied_hours
system_availability
system_availability_schedule
system_occupancy_schedule
system_operation_schedule
zone_recirculation_fan_operation_closed_periods
zone_recirculation_fan_operation_occupied_hours_and_extension_periods
 
get_system_parameters(layer_number) -> dictionary
Get dictionary of system parameter data.
Possible dictionary entries:
 
autosized_system_air_fan_max_flow_rate
basis_for_system_outdoor_air_requirement
chilled_water_loop_circuit
cooling_coil_model_type
cooling_coil_system_type
direct_humidification_efficiency
energy_recovery_latent_heat
energy_recovery_option
energy_recovery_power
energy_recovery_sensible_heat
heat_source_or_loop
heating_coil_model_type
heating_coil_system_type
heating_mode_max
indirect_humidification_efficiency
is_direct_evaporative_cooling
is_energy_recovery_exhaust_air_available
is_energy_recovery_used
is_indirect_evaporative_cooling
is_one_hundred_percent_outside_air_system
is_outdoor_air_economizer_dewpoint_temperature_high_limit
is_outdoor_air_economizer_differential_enthalpy_limit
is_outdoor_air_economizer_drybulb_temperature_high_limit
is_outdoor_air_preheat_coil
is_system_supply_air_dewpoint_temperature_high_limit
is_system_supply_air_relative_humidity_low_limit
outdoor_air_economizer_dewpoint_temperature_high_limit
outdoor_air_economizer_differential_enthalpy_limit
outdoor_air_economizer_drybulb_temperature_high_limit
outdoor_air_preheat_coil
override_system_air_fan_autosizing
prm_baseline_system_pressure_drop_adjustment
reset_system_minimum_outside_air_per_zone
system_average_outdoor_air_fraction_cooling
system_average_outdoor_air_fraction_heating
system_cooling_coil_minimum
system_exhaust_airflow_per_zone_requirements
system_exhaust_airflow_per_zone_requirements_per_area
system_minimum_outdoor_air_intake
system_minimum_outdoor_air_intake_make_up
system_minimum_outdoor_air_intake_make_up_per_area
system_minimum_outdoor_air_intake_per_area
system_minimum_sat
system_sat_reset
system_supply_air_dewpoint_temperature_high_limit
system_supply_air_relative_humidity_low_limit
system_supply_fan_design_flow_rate
system_supply_fan_design_flow_rate_per_area
system_supply_fan_minimum_flow
system_uncorrected_outdoor_air_requirement
system_ventilation_efficiency
total_zone_minimum_primary_outside_air_flow_rates
ventilation_air_tampering_maximum
ventilation_air_tampering_minimum
ventilation_design_primary_airflow_cooling
ventilation_design_primary_airflow_heating
 
get_zone_temperature_humidity_equipment(layer_number) -> dictionary
Get dictionary of zone temperature, humidity and equipment data.
Possible dictionary entries:
 
chilled_water_loop_circuit
cooling_availability_schedule_profile_id
cooling_coil_leaving_air_temperature
cooling_coil_model_type
cooling_coil_system_type
cooling_control_throttling_range
cooling_design_supply_air_temperature
cooling_design_zone_air_temperature
cooling_setback_setpoint
cooling_setpoint
cooling_setpoint_operation_schedule_used
cooling_setpoint_switching_schedule_profile_id
cooling_setpoint_variation
cooling_source
cooling_system_operation_schedule_used
cooling_thermostat_temp_setpoint_used
dehumidification
heating_availability_schedule_profile_id
heating_coil_leaving_air_temperature
heating_coil_model_type
heating_coil_system_type
heating_control_throttling_range
heating_design_supply_air_temperature
heating_design_zone_air_temperature
heating_setback_setpoint
heating_setpoint
heating_setpoint_operation_schedule_used
heating_setpoint_switching_schedule_profile_id
heating_setpoint_variation
heating_source
heating_system_operation_schedule_used
heating_thermostat_temp_setpoint_used
humidification
is_force_cooling_airflow
is_high_limit_only_when_outside_air_ventilation_engaged
is_update_space_data
system_level_cooling_equipment_used
system_level_heating_equipment_used
thermal_template
zone_relative_humidity_high_limit
zone_relative_humidity_low_limit
zone_rh_high_limit_evaporated_cooling
 
get_zone_ventilation_exhaust(layer_number) -> dictionary
Get dictionary of zone ventilation & exhaust data.
Possible dictionary entries:
 
621_default_occupancy_per_are
621_default_occupancy_used
621_occupancy
ashrae_170_function_category
ashrae_621_version
basis_for_zone_outside_air_requirement
breathing_zone
breathing_zone_per_area
cooling_air_distribution_effectiveness
cooling_discharge_airflow
cooling_discharge_outdoor_air_fraction
cooling_percent_max_primary_airflow
cooling_system_fraction_zone_recirculated_air
cooling_zone_outdoor_airflow
cooling_zone_outdoor_airflow_per_area
cooling_zone_primary_air_fraction_of_total_discharge
cooling_zone_primary_airflow
cooling_zone_primary_airflow_outdoor_air_fraction
cooling_zone_ventilation_efficiency
dcv_co2_band_maximum
dcv_co2_band_minimum
dcv_minimum_when_occupied_volume_per_second
dcv_minimum_when_occupied_volume_per_second_per_area
dcv_reduction_when_unoccupied_used
dcv_via_sensors_used
exhaust_air_change_requirement
exhaust_air_change_requirement_air_changes_per_hour
exhaust_air_change_requirement_data
exhaust_air_change_requirement_unit
exhaust_air_change_requirement_used
exhaust_air_change_requirement_volume_per_second
exhaust_air_change_requirement_volume_per_second_per_person
exhaust_air_change_requirement_volume_per_second_per_square_area
exhaust_air_change_requirement_volume_per_second_per_unit
exhaust_air_occupancy_id
exhaust_air_occupancy_units
exhaust_air_occupancy_used
exhaust_airflow
exhaust_airflow_adjacent_space
force_zone_exhaust_used
force_zone_outside_air_used
heating_air_distribution_effectiveness
heating_discharge_airflow
heating_discharge_outdoor_air_fraction
heating_percent_max_primary_airflow
heating_system_fraction_zone_recirculated_air
heating_zone_outdoor_airflow
heating_zone_outdoor_airflow_per_area
heating_zone_primary_air_fraction_of_total_discharge
heating_zone_primary_airflow
heating_zone_primary_airflow_outdoor_air_fraction
heating_zone_ventilation_efficiency
is_dcv
is_dcv_force_vav_fully_open
is_percent_cooling_max_primary_airflow
is_percent_heating_max_primary_airflow
is_zone_supply_one_hundred_percent_transfer_air
make_up_air_option
make_up_air_transfer_percentage
occupancy_category
occupant_diversity
occupant_diversity_factor
outdoor_air_change_percent_requirement_volume
outdoor_air_change_requirement_air_changes_per_hour
outdoor_air_change_requirement_link
outdoor_air_change_requirement_total_volume_per_second
outdoor_air_change_requirement_used
outdoor_air_change_requirement_volume
outdoor_air_change_requirement_volume_per_second_per_area
outdoor_air_change_requirement_volume_per_second_per_person
primary_air_change_requirement
primary_air_change_requirement_air_changes_per_hour
primary_air_change_requirement_used
primary_air_change_requirement_volume_per_second
primary_air_change_requirement_volume_per_second_per_area
primary_air_change_requirement_volume_per_second_per_person
supply_air_transfer
supply_air_transfer_used
transfer_airflow_rate
ventilation_coefficient_ra
ventilation_coefficient_rp
ventilation_increase
ventilation_max_requirement
ventilation_requirement
 
get_zone_loads_airflows() -> dictionary
Get dictionary of zone loads & supply airflows data.
Possible dictionary entries:
 
airside_cooling_load_after_room_contribution
airside_heating_load_after_room_contribution
cooling_adjusted_sat
cooling_airflow_required_latent
cooling_airflow_required_latent_per_area
cooling_design_load_oversizing_factor
cooling_design_loads_with_oversizing_latent
cooling_design_loads_with_oversizing_sensible
cooling_design_max_airflow
cooling_design_max_airflow_per_area
cooling_design_supply_air_temperature
cooling_design_supply_delta_t
cooling_design_temperature_for_airflow
cooling_design_temperature_gain_for_airflow_sizing_used
cooling_design_temperature_source
cooling_design_zone_load_latent
cooling_design_zone_load_sensible
cooling_load_for_terminal_unit
cooling_max_airflow_for_terminal_unit
cooling_max_airflow_for_terminal_unit_per_area
cooling_system_minimum_sat_used
dual_maximum_vav
heating_adjusted_sat
heating_design_load_oversizing_factor
heating_design_loads_with_oversizing
heating_design_max_airflow
heating_design_max_airflow_per_area
heating_design_supply_air_temperature
heating_design_supply_delta_t
heating_design_temperature_for_airflow
heating_design_temperature_gain_for_airflow_sizing_used
heating_design_temperature_source
heating_design_zone_load
heating_load_for_terminal_unit
heating_max_airflow_for_terminal_unit
heating_max_airflow_for_terminal_unit_per_area
heating_system_minimum_sat_used
is_adjust_cooling_airflow
is_adjust_heating_airflow
is_allow_cooling_undersized
is_allow_heating_undersized
is_cooling_design_max_airflow_derived
is_force_cooling_at_least_equal_to_ventilation_rate
is_force_cooling_to_maintain_relative_humidity_setpoint
is_force_heating_at_least_equal_to_ventilation_rate
is_heating_design_max_airflow_derived
percent_of_sat
percent_of_sat_for_airflow_sizing_used
percent_sensible_cooling_load
percent_sensible_heating_load
transfer_air_contribution_cooling
transfer_air_contribution_heating
 
get_zone_airflows_turndown_engineering(layer_number) -> dictionary
Get dictionary of zone airflows, turndown & engineering checks data.
Possible dictionary entries are:
 
active_beam_induced_air_ratio
active_beam_or_induction_unit
ashrae_621_voz_air_changes_per_hour
ashrae_621_voz_volume_per_area
ashrae_621_voz_volume_per_person
ashrae_621_voz_volume_per_second
constant_volume_cooling_airflow
constant_volume_cooling_airflow_per_area
constant_volume_heating_airflow
constant_volume_heating_airflow_per_area
constant_volume_primary_airflow
constant_volume_primary_airflow_per_area
cooling_design_load
cooling_design_load_per_area
cooling_design_load_per_area_inversed
dcv_co2
dcv_min
doas_primary_airflow
doas_primary_airflow_per_area
dynamic_reset_of_system_minimum
exhaust_airflow
exhaust_airflow_per_area
fpb_recirculated_airflow_percentage
fpb_recirculated_airflow_percentage_used
heating_design_load
heating_design_load_per_area
heating_design_load_per_area_inversed
is_active_beam_layer
is_dual_maximum_vav
is_force_design_minimum_airflow_at_least_equal_to_required_ventilation_rate
is_occupants_served_by_system_derived
is_terminal_unit_fan_control
is_ventilation_make_up_for_ea
manually_specified_target_air_changes_per_hour
manually_specified_target_volume_per_second
manually_specified_target_volume_per_second_per_area
manually_specified_target_volume_per_second_per_person
min_primary_supply_airflow
min_primary_supply_airflow_per_area
minimum_outside_air
minimum_outside_air_per_area
minimum_outside_air_per_person
minimum_primary_airflow
minimum_primary_airflow_or_vav_turndown
minimum_primary_airflow_per_area
minimum_primary_airflow_turndown
minimum_primary_airflow_turndown_per_area
occupant_density
occupant_number
occupants_served_by_system
outdoor_air_requirement_at_max_supply_airflow
outdoor_air_requirement_at_minimum_supply_airflow
recirculated_secondary_airflow_max
recirculated_secondary_airflow_max_per_area
recirculated_secondary_airflow_minimum
recirculated_secondary_airflow_minimum_per_area
required_make_up_air_changes_per_hour
required_make_up_volume_per_second
required_make_up_volume_per_second_per_area
required_make_up_volume_per_second_per_person
required_min_air_changes_per_hour
required_min_volume_per_person
required_min_volume_per_second
required_min_volume_per_second_per_area
requirement_as_percent_max_cooling_airflow
requirement_as_percent_max_heating_airflow
requirement_as_percent_minimum_airflow
return_at_max_ea_min_airflow
return_at_max_ea_min_airflow_per_area
system_exhaust_airflow
system_exhaust_airflow_per_area
system_ventilation_efficiency
terminal_fan_unit_control
total_floor_area_served
total_volume_served
transfer_at_max_ea_min_airflow
transfer_at_max_ea_min_airflow_per_area
zone_floor_area
zone_ventilation_max_total_required_air_changes_per_hour
zone_ventilation_max_total_required_air_changes_per_second_per_person
zone_ventilation_max_total_required_volume_per_second
zone_ventilation_max_total_required_volume_per_second_per_area
zone_volume
 
get_zone_airflow_distribution (layer_number) -> dictionary
Get dictionary of zone airflows, turndown & engineering checks data.
Possible dictionary entries are:
 
cooling_load_sensible
cooling_load_latent
heating_load
ventilation_pct
cooling_airflow_pct
cooling_airflow
heating_airflow   
ventilation_airflow