6.1.7.2.15.2 Attributes Defined Here

 
chillers
(list) Chillers (HVACChiller)
condenser_loop_design_pump_power_w
(Optionl[float]) condenser loop design pump power in W
condenser_water_loop
(HVACCondenserWaterLoop) Condenser water loop
cooling_towers
(list[HVACCoolingTower) list of cooling towers
design_cooling_capacity_kw
(float) design cooling capacity in kW
distribution_loss
(float) Distribution loss
dry_fluid_coolers
(list[HVACDryFluidCooler]) list of dry fluid coolers
independent_secondary_loop_enabled
(bool) Whether an independent secondary loop is enabled
is_condenser_water_loop_used
(bool) Is Condenser water loop used
is_thermal_storage_loop_used
(bool) Is Thermal water loop used
loop_configuration
(HVACLoopConfiguration) Loop configuration
oversizing_factor
(float) Oversizing factor
pre_cooling_loop
(HVACPreCoolingLoop) pre cooling loop
primary_chilled_water_demand_side_load_fraction_high_threshold
(float) Higher threshold for primary chilled water demand side load fraction
primary_chilled_water_demand_side_load_fraction_low_threshold
(float) Lower threshold for primary chilled water demand side load fraction
primary_chilled_water_supply_temp_high_threshold
(float) Higher threshold for primary chilled water supply temperature
primary_chilled_water_supply_temp_low_threshold
(float) Lower threshold  for primary chilled water supply temperature
primary_chilled_water_supply_temp_reset_type
(HVACLoopSWTResetType) Primary chilled water supply temperature reset type
primary_chilled_water_supply_temperature
(float) Primary chilled water supply temperature
primary_chilled_water_temperature_difference
(float) Primary chilled water temperature difference
primary_circuit_using_dedicated_chiller_pumps
(float) Primary circuit using dedicated chiller pumps
primary_design_flow_rate
(float) primary loop design flow rate in l/s
primary_outdoor_dew_point_temp_high_threshold
(float) Higher threshold for primary outdoor dew point temperature
primary_outdoor_dew_point_temp_low_threshold
(float) Lower threshold for primary outdoor dew point temperature
primary_outdoor_dry_bulb_temp_high_threshold
(float) Higher threshold for primary outdoor dry bulb temperature
primary_outdoor_dry_bulb_temp_low_threshold
(float) Lower threshold for primary outdoor dry bulb temperature
primary_pump_power_w
(float) primary loop pump power in w
primary_specific_pump_power
(float) Primary specific pump power at design flow in W/(l/s)
secondary_chilled_water_demand_side_load_fraction_high_threshold
(float) Higher threshold for secondary chilled water demand side load fraction
secondary_chilled_water_demand_side_load_fraction_low_threshold
(float) Lower threshold for secondary chilled water demand side load fraction
secondary_chilled_water_supply_temp_high_threshold
(float) Secondary chilled water supply temp high threshold
secondary_chilled_water_supply_temp_low_threshold
(float) Lower threshold for secondary chilled water supply temperature
secondary_chilled_water_supply_temp_reset_type
(HVACLoopSWTResetType) Secondary chilled water supply temperature reset type
secondary_chilled_water_supply_temperature
(float) Secondary chilled water supply temperature
secondary_chilled_water_temperature_difference
(float) Secondary chilled water temperature difference
secondary_loop_design_flow_rate
(Optionl[float]) secondary loop design flow rate in l/s
secondary_loop_pump_power_w
(Optionl[float]) secondary loop design pump power in watts
secondary_outdoor_dew_point_temp_high_threshold
(float) Higher threshold for secondary outdoor dew point temperature
secondary_outdoor_dew_point_temp_low_threshold
(float) Lower threshold for secondary outdoor dew point temperature
secondary_outdoor_dry_bulb_temp_high_threshold
(float) Higher threshold for secondary outdoor dry bulb temperature
secondary_outdoor_dry_bulb_temp_low_threshold
(float) Lower threshold for secondary outdoor dry bulb temperature
secondary_specific_pump_power
(float) Secondary specific pump power at design flow in W/(l/s)
thermal_storage_loop
(list) Thermal storage loops (HVACThermalStorageLoop)