|
AuxEnergyMethod_type
|
SFPs, SFPs_with_min_AEV, SFPs_and_AEV, AEV
|
|
cmm_free_cooling
|
not_a_cmm_system, natural_ventilation, mechanical_ventilation
|
|
Conditioning_type
|
external_air, temperature_from_schedule
|
|
CoolingMechanism_type
|
air_conditioning, mechanical_ventilation, natural_ventilation
|
|
dhw_parent_type
|
unset, dedicated_dhw_boiler, standalone_water_heater, instantaneous_dhw_only, instantaneous_combi, heat_pump
|
|
fuel_type
|
anthracite, biogas, biomass, coal, district_heating, dual, elec, grid_displaced_elec, lpg, misc_a, misc_b, misc_c, misc_d, misc_e, misc_f, misc_g, misc_h, misc_i, misc_j, misc_k, misc_l, misc_m, misc_n, misc_o, misc_p, misc_q, misc_r, misc_s, misc_t, misc_u, misc_v, misc_w, misc_x, misc_y, misc_z, nat_gas, none, oil, smokeless, waste, grid_displaced_pv
|
|
Insulation_type
|
Uninsulated, loose_jacket, factory_insulated
|
|
ncm_air_supply_mechanism
|
centralised_ac, zonal_supply_system_with_remote_fan, zonal_extract_system_with_remote_fan, local_ventilation_serving_single_area, other_local_ventilation_units
|
|
ncm_chiller_power
|
less_than_100_kw, less_than_500_kw, less_than_750_kw, greater_than_750_kw
|
|
ncm_chiller_type
|
air_cooled, water_cooled, remote_condenser, heat_pump_gas_oil, heat_pump_electric
|
|
ncm_eca_list
|
not_on_list, after_2001, before_2005, from_2005, uplift_in_2006
|
|
ncm_heat_recovery
|
no_heat_recovery, plate_heat_exchanger, heat_pipes, thermal_wheel, run_around_coil
|
|
ncm_heat_source
|
lthw_boiler, mthw_boiler, hthw_boiler, air_heater, unflued_gas_warm_air_heater, unitary_radiant_heater, radiant_heater, unflued_radiant_heater, direct_or_storage_electric_heater, heat_pump_air_source, heat_pump_ground_or_water_source, room_heater, district_heating, direct_gas_firing, chp, heat_pump_gas_oil_air_source, heat_pump_gas_oil_ground_or_water_source, heat_pump_electric_air_source, heat_pump_electric_ground_or_water_source
|
|
ncm_leakage_standard
|
class_l1, class_l2, class_l3, not_compliant
|
|
ncm_leakage_test
|
not_tested, class_a, class_b, class_c, class_d
|
|
ncm_pump_type
|
constant_speed, variable_speed_differential_sensor_pump, variable_speed_differential_sensor_system, variable_speed_multiple_pressure_sensors, none
|
|
ncm_system_type
|
not_set, generic_heating_only_electrical_resistance, generic_heating_only_other_systems ,generic_heating_and_mechanical_cooling, central_heating_using_water_radiators, central_heating_using_water_convectors, central_heating_using_water_floor_heating, central_heating_using_air_distribution, other_local_room_heater_fanned, other_local_room_heater_unfanned, unflued_radiant_heater, flued_radiant_heater, multi_burner_radiant_heaters, flued_forced_convection_air_heaters, unflued_forced_convection_air_heaters, single_duct_vav, dual_duct_vav, indoor_packaged_cabinet, fan_coil_systems, induction_system, constant_volume_system_fixed, constant_volume_system_variable, multizone, terminal_reheat, dual_duct, chilled_ceilings_or_passive_chilled_beams_displacement_ventilation, active_chilled_beams, water_loop_heat_pump, split_or_multisplit_systems, single_room_cooling_system, chilled_ceilings_or_passive_chilled_beams_mixed_ventilation, variant_refrigerant_flow, no_heating_or_cooling
|
|
shw_circulation_sys
|
thermosiphon_system, forced_circulation_system_with_pv, forced_circulation_system_with_no_pv
|
|
shw_collector_type
|
unglazed, flat_panel, evacuated
|
|
shw_insulation_type
|
uninsulated, loose_jacket, factory_insulated
|
|
shw_preheating_type
|
separate_solar_cylinder, combined_cylinder
|
|
SolarHeating_type
|
none, flat, parabolic
|