chillers
|
|
|
condenser_loop_design_pump_power_w
|
(Optionl[float]) condenser loop design pump power in W
|
|
condenser_water_loop
|
|
|
cooling_towers
|
(list[HVACCoolingTower) list of cooling towers
|
|
design_cooling_capacity_kw
|
(float) design cooling capacity in kW
|
|
distribution_loss
|
(float) Distribution loss
|
|
dry_fluid_coolers
|
(list[HVACDryFluidCooler]) list of dry fluid coolers
|
|
independent_secondary_loop_enabled
|
(bool) Whether an independent secondary loop is enabled
|
|
is_condenser_water_loop_used
|
(bool) Is Condenser water loop used
|
|
is_thermal_storage_loop_used
|
(bool) Is Thermal water loop used
|
|
oversizing_factor
|
(float) Oversizing factor
|
|
pre_cooling_loop
|
(HVACPreCoolingLoop) pre cooling loop
|
|
primary_chilled_water_demand_side_load_fraction_high_threshold
|
(float) Higher threshold for primary chilled water demand side load fraction
|
|
primary_chilled_water_demand_side_load_fraction_low_threshold
|
(float) Lower threshold for primary chilled water demand side load fraction
|
|
primary_chilled_water_supply_temp_high_threshold
|
(float) Higher threshold for primary chilled water supply temperature
|
|
primary_chilled_water_supply_temp_low_threshold
|
(float) Lower threshold for primary chilled water supply temperature
|
|
primary_chilled_water_supply_temp_reset_type
|
(int) Primary chilled water supply temperature reset type
|
|
primary_chilled_water_supply_temperature
|
(float) Primary chilled water supply temperature
|
|
primary_chilled_water_temperature_difference
|
(float) Primary chilled water temperature difference
|
|
primary_circuit_using_dedicated_chiller_pumps
|
(float) Primary circuit using dedicated chiller pumps
|
|
primary_design_flow_rate
|
(float) primary loop design flow rate in l/s
|
|
primary_outdoor_dew_point_temp_high_threshold
|
(float) Higher threshold for primary outdoor dew point temperature
|
|
primary_outdoor_dew_point_temp_low_threshold
|
(float) Lower threshold for primary outdoor dew point temperature
|
|
primary_outdoor_dry_bulb_temp_high_threshold
|
(float) Higher threshold for primary outdoor dry bulb temperature
|
|
primary_outdoor_dry_bulb_temp_low_threshold
|
(float) Lower threshold for primary outdoor dry bulb temperature
|
|
primary_pump_power_w
|
(float) primary loop pump power in w
|
|
secondary_chilled_water_demand_side_load_fraction_high_threshold
|
(float) Higher threshold for secondary chilled water demand side load fraction
|
|
secondary_chilled_water_demand_side_load_fraction_low_threshold
|
(float) Lower threshold for secondary chilled water demand side load fraction
|
|
secondary_chilled_water_supply_temp_high_threshold
|
(float) Secondary chilled water supply temp high threshold
|
|
secondary_chilled_water_supply_temp_low_threshold
|
(float) Lower threshold for secondary chilled water supply temperature
|
|
secondary_chilled_water_supply_temp_reset_type
|
(int) Secondary chilled water supply temperature reset type
|
|
secondary_chilled_water_supply_temperature
|
(float) Secondary chilled water supply temperature
|
|
secondary_chilled_water_temperature_difference
|
(float) Secondary chilled water temperature difference
|
|
secondary_loop_design_flow_rate
|
(Optionl[float]) secondary loop design flow rate in l/s
|
|
secondary_loop_pump_power_w
|
(Optionl[float]) secondary loop design pump power in watts
|
|
secondary_outdoor_dew_point_temp_high_threshold
|
(float) Higher threshold for secondary outdoor dew point temperature
|
|
secondary_outdoor_dew_point_temp_low_threshold
|
(float) Lower threshold for secondary outdoor dew point temperature
|
|
secondary_outdoor_dry_bulb_temp_high_threshold
|
(float) Higher threshold for secondary outdoor dry bulb temperature
|
|
secondary_outdoor_dry_bulb_temp_low_threshold
|
(float) Lower threshold for secondary outdoor dry bulb temperature
|
|
thermal_storage_loop
|
|