6.1.28.1 Methods Defined Here
add_layer (material_id, is_cavity)
Add a layer to this construction
delete_layer (layer_id)
Delete a layer from this construction
get_default_resistances ()
Get default surface resistances for different methodologies
get_g_values ()
Get the different g-values as a dictionary.
Dictionary entries are:
bs_en_410
(float)
building_regulations
(float)
bfrc
(float)
get_layers ()
Get a list of layers in this CDB construction
get_properties (u_value_types (optional))
Get a dict of the properties of this CDB construction. The result depends on the optional U value type parameter of type uvalue_types . If no parameter is specified the U value type set in the Project Constructions dialog is used.
get_review_summary_string (...)
Get a summary of this CDB construction as a formatted string. Units are converted to local display preferences.
Get the U Factor of this CDB construction.
The result depends on the U value type parameter of type uvalue_types .
insert_layer (layer_id, insert_before)
Insert a layer into this construction
set_const_class (construction_class)
Set construction class of this CDB construction. See 'construction_class' enum for possible values.
set_f_factor (ffactor)
Set F Factor of this CDB construction
set_properties (properties)
Set properties of this CDB construction via a dictionary.
Possible dictionary entries are:
bfrc_active
display_window
external_shade_active
external_shade_code
external_shade_day_resistance
external_shade_ground_transmittance
external_shade_ground_transmittance_default
external_shade_night_resistance
external_shade_profile
external_shade_radiation_to_lower
external_shade_radiation_to_raise
external_shade_sky_transmittance
external_shade_sky_transmittance_default
external_shade_transmitance_15
external_shade_transmitance_75
external_shade_transmittance_0
external_shade_transmittance_30
external_shade_transmittance_45
external_shade_transmittance_60
external_shade_transmittance_90
frame_absorptance
frame_inside_surface_area_ratio
frame_material
frame_outside_surface_area_ratio
frame_percent
frame_resistance
frame_type
g_value
glazing_type
ground_contact
inside_surface_emissivity
inside_surface_resistance
inside_surface_solar_absorptivity
internal_shade_active
internal_shade_blind_or_curtain
internal_shade_code
internal_shade_day_resistance
internal_shade_frac_daylight_closed
internal_shade_night_resistance
internal_shade_profile
internal_shade_radiation_to_lower
internal_shade_radiation_to_raise
internal_shade_shading_coefficient
internal_shade_short_wave_radiant_fraction
light_transmittance
local_shade_active
local_shade_balcony_depth_h
local_shade_balcony_height
local_shade_balcony_projection
local_shade_code
local_shade_left_fin_offset
local_shade_left_fin_projection
local_shade_overhang_type
local_shade_projection_offset
local_shade_projection_overhang
local_shade_right_fin_offset
local_shade_right_fin_projection
local_shade_window_height
local_shade_window_width
outside_surface_emissivity
outside_surface_resistance
outside_surface_solar_absorptivity
percent_sky_blocked
spacer_type
thermal_bridging_coefficient
visible_light_transmittance