6.1.7.2.70.1 Attributes Defined Here

 
design_condition_outdoor_unit_data
(dict) Dictionary of design condition outdoor unit data. Possible dictionary entries are:
 
cooling_capacity, cooling_cop, cooling_combination_ratio, cooling_average_indoor_wb_temperature, cooling_outdoor_db_temperature, heating_capacity, heating_cop, heating_combination_ratio, heating_average_indoor_db_temperature, heating_average_indoor_wb_temperature, heating_outdoor_wb_temperature, heating_outdoor_db_temperature, cooling_entering_source_loop_temperature, heating_entering_source_loop_temperature
design_parameters
(dict) Dictionary of design parameters. Possible dictionary entries are:
 
performance_curve_set_description, performance_curve_set_name, is_autosize_outdoor_unit, oversizing_factor
reference_condition_indoor_unit_data
(dict) Dictionary of reference indoor unit data. Possible dictionary entries are:
 
cooling_entering_coil_wb_temperature, cooling_outdoor_air_db_temperature, use_same_cooling_temperature_as_outdoor, heating_entering_coil_db_temperature, heating_outdoor_air_wb_temperature, use_same_heating_temperature_as_outdoor, cooling_entering_water_temperature, heating_entering_water_temperature
reference_condition_outdoor_unit_data
(dict) Dictionary of reference condition outdoor unit data. Possible dictionary entries are:
 
cooling_capacity, cooling_cop, cooling_combination_ratio, cooling_average_indoor_wb_temperature, cooling_outdoor_db_temperature, use_same_cooling_temperature_as_indoor, heating_capacity, heating_cop, heating_combination_ratio, heating_average_indoor_db_temperature, heating_average_indoor_wb_temperature, heating_outdoor_wb_temperature, heating_outdoor_db_temperature, use_same_heating_temperature_as_indoor, cooling_entering_source_loop_temperature, heating_entering_source_loop_temperature
system_data
(dict) Dictionary of VRF System data. Possible dictionary entries are:
 
unit_control_profile, source_type, min_part_load_ratio, unit_control, source_water_loop_id, master_thermostat_location_space_id, heat_recovery_mode, is_seperate_piping_values, equivalent_piping_length_cooling, equivalent_ piping_length_heating, piping_level_difference_cooling, piping_level_difference_heating, use_crankcase_heater, crankcase_heater_power, max_outdoor_temp_for_crankcase_heater_operation, use_electric_resistance_backup_heat, backup_cooling_source_cop, backup_heating_source_efficiency, outdoor_temp_operation_range_cooling_minimum, outdoor_temp_operation_range_cooling_maximum, outdoor_temp_operation_range_heating_minimum, outdoor_temp_operation_range_heating_maximum, fan_eir, defrost_strategy, resistive_defrost_heater_capacity, defrost_control, defrost_time_fraction, max_outdoor_temp_for_defrost_operation, cooling_heating_meter, crankcase_heater_meter, electric_resistance_backup_heat_meter, backup_cooling_source_meter, backup_heating_source_meter, fan_meter, defrost_meter