6.1.7.2.15.2 Attributes Defined Here

 
chillers
(list) Chillers (HVACChiller)
condenser_water_loop
(HVACCondenserWaterLoop) Condenser water loop
distribution_loss
(float) Distribution loss
independent_secondary_loop_enabled
(bool) Whether an independent secondary loop is enabled
oversizing_factor
(float) Oversizing factor
primary_chilled_water_demand_side_load_fraction_high_threshold
(float) Higher threshold for primary chilled water demand side load fraction
primary_chilled_water_demand_side_load_fraction_low_threshold
(float) Lower threshold for primary chilled water demand side load fraction
primary_chilled_water_supply_temp_high_threshold
(float) Higher threshold for primary chilled water supply temperature
primary_chilled_water_supply_temp_low_threshold
(float) Lower threshold  for primary chilled water supply temperature
primary_chilled_water_supply_temp_reset_type
(int) Primary chilled water supply temperature reset type
primary_chilled_water_supply_temperature
(float) Primary chilled water supply temperature
primary_chilled_water_temperature_difference
(float) Primary chilled water temperature difference
primary_circuit_using_dedicated_chiller_pumps
(float) Primary circuit using dedicated chiller pumps
primary_outdoor_dew_point_temp_high_threshold
(float) Higher threshold for primary outdoor dew point temperature
primary_outdoor_dew_point_temp_low_threshold
(float) Lower threshold for primary outdoor dew point temperature
primary_outdoor_dry_bulb_temp_high_threshold
(float) Higher threshold for primary outdoor dry bulb temperature
primary_outdoor_dry_bulb_temp_low_threshold
(float) Lower threshold for primary outdoor dry bulb temperature
secondary_chilled_water_demand_side_load_fraction_high_threshold
(float) Higher threshold for secondary chilled water demand side load fraction
secondary_chilled_water_demand_side_load_fraction_low_threshold
(float) Lower threshold for secondary chilled water demand side load fraction
secondary_chilled_water_supply_temp_high_threshold
(float) Secondary chilled water supply temp high threshold
secondary_chilled_water_supply_temp_low_threshold
(float) Lower threshold for secondary chilled water supply temperature
secondary_chilled_water_supply_temp_reset_type
(int) Secondary chilled water supply temperature reset type
secondary_chilled_water_supply_temperature
(float) Secondary chilled water supply temperature
secondary_chilled_water_temperature_difference
(float) Secondary chilled water temperature difference
secondary_outdoor_dew_point_temp_high_threshold
(float) Higher threshold for secondary outdoor dew point temperature
secondary_outdoor_dew_point_temp_low_threshold
(float) Lower threshold for secondary outdoor dew point temperature
secondary_outdoor_dry_bulb_temp_high_threshold
(float) Higher threshold for secondary outdoor dry bulb temperature
secondary_outdoor_dry_bulb_temp_low_threshold
(float) Lower threshold for secondary outdoor dry bulb temperature
thermal_storage_loop
(list) Thermal storage loops (HVACThermalStorageLoop)