6.1.23.1 Methods Defined Here

air_supply() -> dictionary
Air supply data for the Apache system.  Returns dictionary with the following keys:
 
condition
(int) supply condition.  See air_supply_cond_names()
 
cooling_max_flow
(float, l/s) maximum cooling air supply flow rate
OA_max_flow
(float, l/s) maximum outside air supply flow rate
profile (optional)
(string) adjacent condition profile ID, only present if condition = 1
temperature_difference
(float, K) air supply temperature difference (0 for no sizing)
 
apply_ncm()
Applies NCM wizard data to the system. Call this after setting NCM wizard data to update the system itself. If you don’t call this, changes will be made only in the wizard and not the system.
 
auxiliary_energy(show_ncm) -> dictionary
Auxiliary energy data for the Apache system.
 
Parameters:
 
show_ncm (optional)
Whether to show NCM specific data in the output
 
 Returns:
 Dictionary with the following keys:
 
AEV
(float, W/m2) energy value.  Only if method != 0
air_supply_mechanism (optional)
Air supply mechanism
equivalent_energy
(float, kWh/m2/y) equivalent energy in, for 3255hrs operation.  Only if method != 0
method
(int) auxiliary energy method.  See aux_energy_method_names()
off_schedule_AEV
(float, W/m2) off-schedule heating/cooling AEV
SFP (optional)
(float, W/l/s) specific fan power (SFP).  Only if method != 3
 
bivalent_systems_ncm() -> dictionary
Bivalent systems NCM data for the Apache system. Returns dictionary with the following keys:
 
load_for_primary_system
% Load for the primary system
overall_seasonal_efficiency
Overall seasonal efficiency
systems
List of dictionaries of system data (one for each system)
 
System data dictionary contains the following keys:
 
gen_seff
GEN SEFF (fraction)
heat_source
Heat source
load
% Load
meter
Energy meter
 
control() -> dictionary
Control data for the Apache system.  Returns dictionary with the following keys:
 
master_zone
(string) master zone room ID
 
cooling(show_ncm) -> dictionary
Cooling data for the Apache system.
 
Parameters:
 
show_ncm (optional)
Whether to show NCM specific data in the output
 
 
Returns:
 Dictionary with the following keys:
 
cool_vent_mechanism
(int) Cooling/ventilation mechanism.  See cooling_mech_names()
del_eff
(float) Delivery efficiency
free_cooling
(cmm_free_cooling) Changeover mixed mode free cooling
fuel (optional)
(int) Fuel.  Only if has_absorption_chiller == False.  See fuel_names()
gen_size
(float, kW) Generator size
has_absorption_chiller
(Bool) Whether the system has an absorption chiller
nominal_eer
(float, kW/kW) Nominal EER
pump_and_fan_power_perc
(float) Pump & fan power (% of rejected heat)
SEER
(float, kW/kW) Seasonal energy efficiency ratio
SSEER
(float, kW/kW) Seasonal system energy efficiency ratio
 
cooling_ncm() -> dictionary
Cooling NCM data for the Apache system. Returns dictionary with the following keys:
 
  chiller_meter
(VEEnergyMeter) Chiller meter
  default_generator_nominal_eer
(float) Default nominal EER value
  default_generator_seasonal_eer
(float) Default seasonal EER value
  generator_nominal_eer
(float) Nominal EER
  generator_nominal_eer_known
(bool) Do you know the generator nominal EER?
  generator_seasonal_eer
(float) Seasonal EER
  generator_seasonal_eer_known
(bool) Do you know the generator seasonal EER?
  mixed_mode
(bool) Mixed mode operation strategy (SBEM only)
  power
(ncm_chiller_power) Cooling power
  qualify_for_eca
(ncm_eca_list) Does it qualify for ECAs?
  type
(ncm_chiller_type) Cooling type
 
general_ncm() -> dictionary
General NCM data for the Apache system. Returns dictionary with the following keys:
 
is_proxy_for_hvac
(bool) Whether it is a proxy for an ApacheHVAC system
ncm_system_type
(ncm_system_type) NCM system type
 
heating(show_ncm) -> dictionary
Heating data for the Apache system.
 
Parameters:
 
show_ncm (optional)
Whether to show NCM specific data in the output
 
Returns:
Dictionary with the following keys:
 
CHP_heat_output (optional)
(float, kW) heat output of CHP.  Only if CHP is present
CHP_ranking (optional)
(int) ranking of heat source after the CHP plant.  Only if CHP is present
del_eff
(float) delivery efficiency of the generator
fuel
(int) generator fuel.  See fuel_names()
gen_seasonal_eff
(float) seasonal efficiency of the generator
gen_size
(float, kW) generator size
HR_effectiveness
(float) ventilation heat recovery effectiveness
HR_return_temp
(float, °C) ventilation heat recovery return air temperature
Is_heat_pump
(bool) Is it a heat pump?
meter_cef
(float) Meter CEF kgCO2/kWh
meter_pef
(float) Meter PEF kgCO2/kWh
SCoP
(float, kW/kW) seasonal coefficient of performance
used_with_CHP
(bool) whether the heat source is used in conjunction with CHP
 
heating_ncm() -> dictionary
Heating NCM data for the Apache system.
Returns:
     Dictionary with the following keys:
 
boiler_over_15_years_old
(bool)  Whether the boiler is over 15 years old
convectors_have_fans
(bool)  Whether convectors have fans
default_fan_power_ratio
(float)  Default fan power ratio
default_generator_radiant_efficiency
(float)  Default generator radiant efficiency
default_generator_seasonal_efficiency
(float)  Default generator seasonal efficiency
existing_district_heating
(bool) Whether this system is an existing district heating system
fan_power_ratio
(float)  Fan power ratio
fan_power_ratio_known
(bool) Whether the fan power ratio is known
generator_radiant_efficiency
(float)  Generator radiant efficiency
generator_radiant_efficiency_known
(bool)  Whether the generator radiant efficiency is known
generator_seasonal_efficiency
(float) Generator seasonal efficiency
generator_seasonal_efficiency_known
(bool) Do you know the generator seasonal efficiency?
heat_source
(ncm_heat_source) Heat source
installed_after_98
(bool) Whether this system was installed on or after 1998
meter
(VEEnergyMeter) Energy meter
qualify_for_ecas
(ncm_eca_list) Does it qualify for ECAs?
uses_chp
(bool) Whether this system also uses CHP
 
hot_water(show_ncm) -> dictionary
Hot water data for the Apache system.
 
Parameters:
 
show_ncm (optional)
Whether to show NCM specific data in the output
 
Returns:
   Dictionary with the following keys:
 
circulation_losses (optional)
(float, W/m) circulation losses.  Only if secondary circulation is present
cold_water_inlet_temp
(float, °C) mean cold water inlet temperature
default_generator_seaonal_efficiency (optional)
(float) Default generator seasonal efficiency
del_eff
(float) DHW delivery efficiency
existing_district_heating (optional)
(bool) Existing distict heating system?
generator_meter (optional)
(VEEnergyMeter) Generator meter
generator_seasonal_efficiency (optional)
(float) Seasonal generator efficiency
generator_type (optional)
(dhw_parent_type)  Generator type
has_ApHVAC_boiler
(Bool) whether the system is served by an ApacheHVAC boiler
has_secondary_circulation
(Bool) whether the system has secondary circulation
has_time_switch (optional)
(Bool) whether or not there is a time switch. Only if secondary circulation is present
insulation_thickness (optional)
(float, mm) insulation thickness. Only if storage is used
insulation_type (optional)
(int) type of insulation.  See insulation_names().Only if storage is used
is_storage_system
(Bool) whether the system is a storage system
later_than_1998 (optional)
(Bool) Later than 1998?
loop_length (optional)
(float, meters) loop length. Only if secondary circulation is present
pump_power (optional)
(float, kW) pump power. Only if secondary circulation is present
storage_losses (optional)
(float, kWh/l/day) storage losses. Only if storage is used
storage_volume (optional)
(float, liters) storage volume.  Only if storage is used
supply_temp
(float, °C) hot water supply temperature
use_default_generator_seaonal_efficiency (optional)
(bool) Do you know the generator seasonal efficiency?
pump_meter
(VEEnergyMeter)  Pump meter
 
metering_provision_ncm() -> dictionary
Metering provision NCM data for the Apache system.
Returns:
Dictionary with the following keys:
 
control_correction
(float) Control correction
provision_for_metering
(bool) Does the system have provisioning for metering?
warns
(bool) Does the metering warn 'out of range' values?
 
set_air_supply(air_supply_data)
Set air supply data from the supplied dictionary.
Dictionary keys are:
 
condition
cooling_max_flow
OA_max_flow
profile
temperature_difference
 
set_auxiliary_energy(aux_data)
Set auxiliary energy data from the supplied dictionary.
Dictionary keys are:
 
AEV
air_supply_mechanism
fan_fraction
method
off_schedule_AEV
SFP
 
set_bivalent_systems_ncm(data)
Set bivalent systems from the supplied list of dictionaries.
Dictionary keys are:
 
heat_source
meter
gen_seff
load
 
set_control(control_id)
Set the master zone control.
 
set_cooling(cooling_data)
Set cooling data from the supplied dictionary.
Dictionary keys are:
 
cool_vent_mechanism
del_eff
free_cooling
fuel
gen_size
has_absorption_chiller
nominal_eer
pump_and_fan_power_perc
SEER
SSEER
 
set_cooling_ncm(data)
Set cooling NCM data from the supplied dictionary.
Dictionary keys are:
 
chiller_meter
generator_nominal_eer
generator_nominal_eer_known
generator_seasonal_eer
generator_seasonal_eer_known
mixed_mode
power
qualify_for_eca
type
 
set_default(system_id)
Set the default system ID.
 
set_general_ncm(data)
Set general NCM data from the supplied dictionary.
Dictionary keys are:
 
is_proxy_for_hvac
ncm_system_type
 
set_heating(heating_data)
Set heating data from the supplied dictionary.
Dictionary keys are:
 
CHP_heat_output
CHP_ranking
fuel
gen_seasonal_eff
gen_size
HR_effectiveness
HR_return_temp
is_heat_pump
meter_cef
meter_pef
SCoP
used_with_CHP
 
set_heating_ncm(data)
Set heating NCM data from the supplied dictionary.
Dictionary keys are:
 
boiler_over_15_years_old
convectors_have_fans
default_fan_power_ratio
default_generator_radiant_efficiency
default_generator_seasonal_efficiency
fan_power_ratio
fan_power_ratio_known
generator_radiant_efficiency
generator_radiant_efficiency_known
generator_seasonal_efficiency
 generator_seasonal_efficiency_known
heat_source
installed_after_98
Is_heat_pump
meter
meter_cef
meter_pef
qualify_for_ecas
uses_chp
 
set_hot_water(hot_water_data)
Set hot water data from the supplied dictionary.
Dictionary keys are:
 
circulation_losses
cold_water_inlet_temp
del_eff
existing_district_heating
generator_meter
generator_seasonal_efficiency
generator_type
has_ApHVAC_boiler
has_secondary_circulation
has_time_switch
insulation_thickness
insulation_type
is_storage_system
later_than_1998
loop_length
pump_power
storage_losses
storage_volume
supply_temp
use_default_generator_seaonal_efficiency
 
set_metering_provision_ncm(data)
Set metering provsion NCM data from the supplied dictionary.
Dictionary keys are:
 
provision_for_metering
warns
 
set_name(name)
Set the system name.
 
set_solar_water_heating(sol_water_data)
Set solar hot water heating data from the supplied dictionary.
Dictionary keys are:
 
abso_absorptance
abso_radius
area
azimuth
coeff_a1
coeff_a2
coeff_c1
coeff_c2
conversion_eff
cover_trans
degradation_factor
flow_rate
fluid_flow
has_space_or_process_heating
heat_capacity
HX_effectiveness
intercept_factor
mirror_reflectance
num_rows
pump_fuel
pump_power
refl_focal_length
refl_length
refl_width
return_temp
shading_factor
storage_loss
supply_temp
tank_heat_loss
tank_volume
tilt
tube_extension
type
units_per_row
volume
 
set_solar_water_heating_ncm(data)
Set solar hot water heating NCM data from the supplied dictionary.
Dictionary keys are:
 
a1
a2
circulation_system
heat_transfer_rate
iam
insulation_thickness
insulation_type
is_heat_exchanger
is_solar_heating
nominal_pump_power
overall_heat_loss_coeff
panel_area
panel_azimuth
panel_tilt
performance_parameters
performance_parameters_known
pipes_insulated
preheating_type
sigma_0
volume
 
set_system_adjustment_ncm(data)
Set system adjustment NCM data from the supplied dictionary.
Dictionary keys are:
 
ahu_meets_standards
cen_class
ductwork_leakage_test
ductwork_leakage_test_done
pump_type
specific_fan_power
specific_fan_power_known
 
set_system_controls_ncm(data)
Set system control NCM data from the supplied dictionary.
 Dictionary keys are:
 
central_time_control
local_temperature_control
local_time_control
optimum_start_stop_control
weather_compensation_control
 
set_ventilation_ncm(data)
Set ventilation NCM data from the supplied dictionary.
Dictionary keys are:
 
air_supply_mechanism
heat_recovery_type
heat_recovery_efficiency_known
heat_recovery_efficiency
variable_heat_recovery
 
solar_water_heating() -> dictionary
Solar water heating data for the Apache system.  Returns dictionary with the following keys:
 
type
Collector type
 
Flat collectors also have the following keys:
 
area
(float, m2) Area
azimuth
(float, Degrees clockwise from North) azimuth
coeff_a1
(float, W/m2/K) First order heat loss coefficient (a1)
coeff_a2
(float, W/m2/K) Second order heat loss coefficient (a2)
conversion_eff
(float) Conversion efficiency at ambient temperature
degradation_factor
(float) Degradation factor
flow_rate
(float, l/h/m2) Flow rate
HX_effectiveness
(float) Heat exchanger effectiveness
pump_fuel
(fuel_type) Pump fuel
pump_meter_branch
(tuple) Pump meter branch
pump_power
(float, kW) Pump power
shading_factor
(float) Shading factor
storage_loss
(float, kWh/l/day) Storage loss at max. temperature
tilt
(float, degrees from horizontal) Tilt
volume
(float, liters) Volume
 
Parabolic collectors also have the following keys:
 
abso_absorptance
(float) Absorptance of absorber tube
abso_radius
(float, m) Radius of absorber tube
azimuth
(float, degrees from North) Angle of collector tube
coeff_c1
(float) First order loss coefficient per unit aperture area
coeff_c2
(float) Second order loss coefficient per unit aperture area
cover_trans
(float) Transmittance of cover tube
fluid_flow
(float, l/h/m2) Total fluid flow
heat_capacity
(float, J/kg/K) Fluid specific heat capacity
HX_effectiveness
(float) Heat exchanger effectiveness
intercept_factor
(float) Fraction of beam radiation intercepted by receiver
mirror_reflectance
(float) Reflectance of the mirror
num_rows
(int) Number of rows (in parallel)
pump_fuel
(fuel_type) Pump fuel
pump_meter_branch
(tuple) Pump meter branch
pump_power
(float, kW) Pump power
refl_focal_length
(float, m) Focal length of one reflector collector unit
refl_length
(float, m) Length of one reflector collector unit
refl_width
(float, m) Width of one reflector collector unit
tank_heat_loss
(float, kWh/l/day) Design tank heat loss
tank_volume
(float, l) Tank volume
tube_extension
(float, m) Extension of tube beyond a single unit
units_per_row
(int) Collector units per row (in series)
 
Flat and parabolic collectors also have the following keys:
has_space_or_process_heating
Whether there is space or process heating
return_temp (optional)
Water loop design return temperature (°C)
supply_temp (optional)
Water loop design supply temperature (°C)
 
solar_water_heating_ncm() -> dictionary
Solar water heating data for NCM mode. Returns dictionary with the folllowing keys:
 
a1
a1 W/m^2K
a2
a2 W/m^2
circulation_system
Circulation system
heat_transfer_rate
Heat transfer rate (W/K)
iam
IAM
insulation_thickness
Insulation thickness (mm)
insulation_type
Insulation type
is_heat_exchanger
Is there a heat exchanger?
is_solar_heating
Is there a solar heating system?
nominal_pump_power
Nomincal pump power, Paux (W)
overall_heat_loss_coeff
Overall heat loss coeff (W/K)
panel_area
Solar panel area (m^2)
panel_azimuth
Solar panel azimuth (degrees clockwise from north)
panel_tilt
Solar panel tilt (degrees from horizontal)
performance_parameter
Performance parameter
performance_parameters_known
Do you know the performance parameters?
pipes_insulated
Are pipes to back-up system insulated?
preheating_type
Pre-heating type
sigma_0
Sigma-0
volume
Solar storage volume (l)
 
system_adjustment_ncm() -> dictionary
System adjustment NCM data for the Apache system. Returns dictionary with the folllowing keys:
 
  ahu_meets_standards
(bool) Does the AHU meet CEN leakage standards?
  air_leakage
(float) Air leakage
  cen_class
(ncm_leakage_standard) CEN classification met by the AHU
  default_specific_fan_power
(float) Default specific fan power
  ductwork_leakage_test
(ncm_leakage_test) CEN classification met by the ductwork
  ductwork_leakage_test_done
(bool) Has the ductwork been leakage tested?
  pump_type
(ncm_pump_type) Pump type
  specific_fan_power
(float) Specific Fan Power of the system
  specific_fan_power_known
(bool) Do you know the Specific Fan Power?
 
system_controls_ncm() -> dictionary
  System controls NCM data for the Apache system. Returns dictionary with the following keys:
 
central_time_control
(bool) Central time control
local_temperature_control
(bool) Local temperature control (i.e., room by room)
local_time_control
(bool) Local time control (i.e., room by room)
optimum_start_stop_control
(bool) Optimum start/stop control
weather_compensation_control
(bool) Weather compensation control
 
ventilation_ncm() -> dictionary
Ventilation NCM data for the Apache system. Returns dictionary with the following keys:
 
air_supply_mechanism
(ncm_air_supply_mechanism) Air supply mechanism
cool_vent_mechanism
(CoolingMechanism_type) Cooling/ventilation mechanism
default_heat_recovery_efficiency
(float) Default heat recovery seasonal efficiency
heat_recovery_efficiency
(float) Heat recovery seasonal efficiency
heat_recovery_efficiency_known
(bool) Do you know the heat recovery seasonal efficiency?
heat_recovery_type
(ncm_heat_recovery_type) Heat recovery type
variable_heat_recovery
(bool) Variable heat recovery efficiency?