6.1.18.1 Methods Defined Here

Init(pcProjectFolder, pcAPSFile,  pcAPSComparisonFiles, oStrInfoMessage, oStrError, eMode, oComputeCosts) -> Bool
 
Init the tariffs engine.
 
Parameters:
 
eMode
(int) TariffsEngine engine mode (EModes). Default is MODE_NORMAL.
oComputeCosts
(int) Compute utilities or not (EComputeCosts). Default is COMPUTE_COSTS_YES.
oStrError [OUT]
(object) Error message if any
oStrInfoMessage [OUT]
(object) Non error message to show after initialization. If not nullptr, it has a message and has to be deleted.
pcAPSComparisonFiles
(string) 3 options:
 
·        Files separated by ? that will be stored for comparing. I.e : File1 ? File2 ? File3
  • Empty string. Comparison files will be cleared so no fileswill be used to compare to.
  • nullptr. Comparison files won't be modified and pcAPSFile will be compared to them.
 
pcAPSFile
(string) APS file with path. I.e: C:\\My project\\vista\\test.aps
pcProjectFolder 
(string) MIT project folder ending by '\' or not. I.e: C:\\My project\\
 
Returns:
Bool  -  True if success.
                 False if fail. See oStrError.
 
Basic usage:
 
import iesve
 
  strProjectFolder = 'C:\\MyProject'
  strAPSFile = 'C:\\MyProject\\vista\\a_tariff analysis.aps'
  strAPSComparisonFiles = 'C:\\MyProject\\vista\\prb.aps'
  strInfoMessage = iesve.TariffsEngine.String()
  strError = iesve.TariffsEngine.String()
 
  te = iesve.TariffsEngine()
 
  if (not te.Init(strProjectFolder, strAPSFile, strAPSComparisonFiles, strInfoMessage, strError)) :
    print(strError.GetString())
  else:
    print("Init ok")
 
    if (strInfoMessage.Empty() == False) :
      print(strInfoMessage.GetString())
 
SetComparisonProfile(pcFiles)
Sets the file(s) to compare with.
 
Parameters:
 
pcFiles
(string) string with the files separated by ? or empty. I.e: "File1?File2?File3"
 
Returns:
  -
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  te.SetComparisonProfile("prb.aps?prb2.aps")
 
GetUtilitiesNamesAndIds() -> List
Gets a tuple with the utilities names and its ids.
 
Parameters:
  -
 
Returns:
  List  -  list with the utilities.
 
    I.e: [['Electricity', 0], ['Gas', 1], ['Oil', 2], ['Coal', 3],
          ['Miscellaneous', 4], ['Renewables', 5]]
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  utilities = te.GetUtilitiesNamesAndIds()
  print(utilities)
 
GetSelectedCurrency() -> Tuple
Gets a tuple with the selected currency data.
 
Parameters:
  - 
 
Returns:
  Tuple  -  tuple with the selected currency.
    I.e: ['Polish zloty', 'PLN', 'Poland', 'PLN']
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  currency = te.GetSelectedCurrency()
  print(currency)
 
GetSuppliersForUtility(iUtilityId) -> List
Gets a tuples list with the suppliers belonging to a utility.
 
Parameters:
 
iUtilityId 
(int) EUtilities value
 
Returns:
  List  -  tuples list with the suppliers belonging to the
                  utility iUtilityId. Each tuple has utility name
                  and id, that can be used for other functions.
 
                  I.e: [['Electricity Commercial Supplier', 1],
                        ['Electricity Domestic Supplier', 4]
                       ]
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  suppliers = te.SuppliersForUtility(te.EUtilities.GAS)
  print(suppliers)
 
GetTariffsForSupplier(iSupplierId, strCurrencyId) -> List
Gets a tuple with the tariffs belonging to a supplier and,
optionally, a currency.
 
Parameters:
 
iSupplierId 
(int) Supplier id whose tariffs will be retrieved.
strCurrencyId 
(string) Currency id the tariffs will have to have in order to be retrieved. If "", no currency checking will be carried out. Default "".
 
 
Returns:
  List  -  tuples list with the tariffs belonging to the
    supplier whose id is strSupplierId and using the currency if
    specified.
 
                  I.e: [['Unrestricted Tariff (£ GBP)', 12],
                        ['Two Rate Tariff (£ GBP)', 13],
                        ['Economy-7 Tariff (£ GBP)', 21],
                        ['Unrestricted Tariff ($ USD)', 23],
                        ['Two Rate Tariff ($ USD)', 24],
                        ['Economy-7 Tariff ($ USD)', 28]
                       ]
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  tariffs = te.GetTariffsForSupplier(2)
  print(tariffs)
 
GetTariffName(iUtilityId, iTariffId) -> String
Retrieves the name of the tariff whose id is iTariffId and belongs
to the utility iUtilityId.
 
Parameters:
 
iTariffId 
(int) Tariff's id to check
iUtilityId
(int) EUtilities value. Neither miscellaneous nor renewables are possible.
 
Returns:
  String  -  tariff name or "" if not found.
 
Basic Usage:
 
  te = iesve.TariffsEngine(...)
  name = te.GetTariffName(iesve.TariffsEngine.EUtilities.ELECTRICITY, 4)
  print(name)
 
GetSelectedTariffName(iUtilityId) -> String
Retrieves the name of the selected tariff that belongs to the utility iUtilityId.
 
Parameters:
 
iUtilityId
(int) EUtilities value. Neither miscellaneous nor renewables are possible.
 
Returns:
  String  -  tariff name or "" if not found.
 
Basic Usage:
 
  te = iesve.TariffsEngine(...)
  name = te.GeSelectedtTariffName(iesve.TariffsEngine.EUtilities.ELECTRICITY)
  print(name)
 
GetTariffCurrencyUnits(iUtilityId, iTariffId) -> String
Returns a text with the symbol of the selected currency divided by
the unit of the tariff whose id is iTariffId. I.e: $/T
 
Parameters:
 
iTariffId 
(int) Tariff's id
iUtilityId 
(int) EUtilities value. Neither miscellaneous nor renewables are possible.
 
Returns:
  String  -  A text with the symbol of the selected currency divided
    by the unit of the tariff whose id is iTariffId. I.e: $/T
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  currencyUnits = te.GetTariffCurrencyUnits(iesve.TariffsEngine.EUtilities.ELECTRICITY, 4)
  print(currencyUnits)
 
GetRatesTimeSeries(iUtility,  iFirstDay,  iLastDay) -> Numpy Object
Returns a numpy object with the rates applied per time gap from iFirstDay to iLastDay for utility iUtility, that has previously been computed.
 
Parameters:
 
iFirstDay
(int) First day whose rates per time gap will be stored: 1,...365, 366… If -1, it will be taken from the APS.
Default value = -1
iFirstDay<=iLastDay
iLastDay
(int) Last day whose rates per time gap will be stored: 1,...365, 366... If -1, it will be taken from the APS.
Default value = -1
 iFirstDay<=iLastDay
iUtility
(int) EUtilities value.
 
  Returns:
    Numpy Object  -  numpy object with the proposed demand cost per time gap.
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  costsPerGap = te.GetRatesTimeSeries(iesve.TariffsEngine.EUtilities.OIL, 1, 365)
  print(str(costsPerGap.size) + " values retrieved")
 
  if costsPerGap.size>0:
    print(costsPerGap[0])
 
ComputeWithTariff(iUtilityId, iSupplierId, iTariffId)
Computes the utility iUtilityId using supplier iSupplierId and tariff iTariffId.
 
Parameters:
 
iSupplierId
(int) Supplier id to be set. If not found, an exception is thrown.
iTariffId
(int) Tariff id to be set. If not found or doesn't belong to iSupplierId, an exception is thrown.
iUtilityId
(int) EUtilities value.
 
Returns:
  - 
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  te.ComputeWithTariff(iesve.TariffsEngine.EUtilities.OIL, 1, 3)
 
ComputeWithFlatRate(iUtilityId, dbFlatRate)
Computes the utility's costs using the flat rate.
 
Parameters:
 
dbFlatRate 
(float) flat rate to use. If <0, the current utility's flat rate will be used.
iUtilityId 
(int) EUtilities value.
 
Returns:
  - 
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  te.ComputeWithFlatRate(iesve.TariffsEngine.EUtilities.COAL, .075)
 
GetProposedNetCost(iUtilityId) -> float
Returns the proposed cost for a utility or total.
 
Parameters:
 
iUtilityId 
(int) EUtilities value. If -1, the total cost of all of the utilities summed up will be returned.
 
Returns:
  float  -  proposed total cost.
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  print(te.GetProposedNetCost(iesve.TariffsEngine.EUtilities.GAS))
 
GetBaselineNetCost(iUtilityId) -> float
Returns the baseline cost for a utility or total.
 
Parameters:
 
iUtilityId 
(int) EUtilities value. If -1, the total cost of all of the utilities summed up will be returned.
 
Returns:
  float  -  baseline total cost.
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  print(te.BaselineNetCost(iesve.TariffsEngine.EUtilities.GAS))
 
Improvement() ->  float
Read only property containing the % of improvement.
 
Parameters:
  -
 
Return Value:
  float  -  % improvement.
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  print(te.Improvement)
 
AcceptChanges() -> String
Accepts changes done. It will save the results, selected tariffs etc.
 
Parameters:
  - 
 
Returns:
  String  -  Error message if any.
 
Basic usage:
 
  te = iesve.TariffsEngine(...)
  error = te.AcceptChanges()
 
  if error:
    print(error)