| Material  Description  | Conductivity  | Sp. Heat Capacity  | Density  | 
|  | (W/mK)  | (J/kgK)  | (kg/m3)  | 
| Asphalts & Other Roofing Finishes  |  |  |  | 
| Asbestos Cement Decking  | 0.360  | 1050  | 1500  | 
| Asbestos Cement Sheet  | 0.360  | 1050  | 700  | 
| Asphalt  | 0.500  | 1000  | 1700  | 
| Felt/Bitumen Layers  | 0.500  | 1000  | 1700  | 
| Asphalt/Asbestos Tiles  | 0.550  | 837  | 1900  | 
| Roofing Felt  | 0.190  | 837  | 960  | 
| Asphalt Mastic Roofing  | 1.150  | 837  | 2325  | 
| Built-Up Roof – BR01  | 0.162  | 1464  | 1121  | 
| Roof Gravel/Slag – RG01  | 1.442  | 881  | 1674  | 
|  |  |  |  | 
|  |  |  |  | 
| Boards, Sheets & Deckings  |  |  |  | 
| Asbestos Cement Decking  | 0.360  | 1050  | 1500  | 
| Asbestos Cement Sheet  | 0.360  | 1050  | 700  | 
| Fibreboard  | 0.060  | 1000  | 300  | 
| Gypsum Plasterboard  | 0.160  | 840  | 950  | 
| Polyurethane Board  | 0.025  | 1400  | 30  | 
| Hardboard (Medium)  | 0.080  | 2000  | 600  | 
| Hardboard (Standard)  | 0.130  | 2000  | 900  | 
| Cork Board  | 0.040  | 1888  | 160  | 
| Chipboard  | 0.150  | 2093  | 800  | 
| Weatherboard  | 0.140  | 2000  | 650  | 
| Perlite Plasterboard  | 0.180  | 837  | 800  | 
| Cratherm Board  | 0.050  | 837  | 176  | 
| Anti-Sun Glass Cladding  | 1.050  | 750  | 2500  | 
| Plate-Glass Cladding  | 0.760  | 837  | 2710  | 
| 4mm Clear Float Cladding  | 1.050  | 750  | 2500  | 
| Lightweight Metallic Cladding  | 0.290  | 1000  | 1250  | 
| Asbestos-Cement Board  | 0.580  | 1000  | 1900  | 
| Fibreboard – Tile & Lay-In Panel  | 0.058  | 600  | 290  | 
| Paperboard – Laminated  | 0.072  | 1400  | 480  | 
| Hardboard – Medium Density  | 0.105  | 1300  | 800  | 
| Paperboard – Homogeneous From Repulped Paper  | 0.072  | 1200  | 480  | 
| Hardboard – High Density  | 0.820  | 1300  | 880  | 
| Hardboard – Standard Tempered Grade  | 0.144  | 1300  | 1010  | 
| Particleboard – Low Density  | 0.102  | 1300  | 590  | 
| Particleboard – Medium Density  | 0.135  | 1300  | 800  | 
| Particleboard – High Density  | 0.170  | 1300  | 1000  | 
| Asbestos-Cement Board – AB01  | 0.597  | 837  | 1922  | 
| Cement Mortar – CM01  | 0.721  | 837  | 1858  | 
| Particle Board Underlay – PB04  | 0.311  | 1213  | 1202  | 
| Hard Board Medium Density Siding – HB01  | 0.094  | 1171  | 641  | 
| Hard Board Medium Density Others – HB02  | 0.105  | 1297  | 801  | 
| Hard Board High Density – HB03  | 0.118  | 1381  | 881  | 
| Hard Board High Density Standard Service Tempered – HB04  | 0.144  | 1381  | 1009  | 
|  |  |  |  | 
|  |  |  |  | 
| Brick & Block Work  |  |  |  | 
| Brickwork (Outer Leaf)  | 0.840  | 800  | 1700  | 
| Brickwork (Inner Leaf)  | 0.620  | 800  | 1700  | 
| Concrete Block (Heavyweight)  | 1.630  | 1000  | 2300  | 
| Concrete Block (Medium)  | 0.510  | 1000  | 1400  | 
| Concrete Block (Lightweight)  | 0.190  | 1000  | 600  | 
| Concrete Paviour  | 0.960  | 840  | 2000  | 
| Foam Slag  | 0.250  | 960  | 1040  | 
| Vermiculite Insulating Brick  | 0.270  | 837  | 700  | 
| Aerated Concrete Block  | 0.240  | 1000  | 750  | 
| Thermalite - High Strength  | 0.190  | 1050  | 760  | 
| Thermalite 'Turbo'  | 0.110  | 1050  | 480  | 
| Thermalite 'Shield'/'Smooth Face'  | 0.170  | 1050  | 650  | 
| Glass Block  | 0.700  | 837  | 2500  | 
| Common Brick – BK01  | 0.721  | 837  | 1922  | 
| Face Brick – BK04  | 1.310  | 921  | 2083  | 
| Face Brick – HF-A2  | 1.331  | 921  | 2083  | 
| Face Brick – HF-A7  | 1.331  | 921  | 2003  | 
| Common Brick – HF-C4  | 0.727  | 837  | 1922  | 
|  |  |  |  | 
|  |  |  |  | 
| Carpet  |  |  |  | 
| Wilton Carpet  | 0.060  | 1360  | 186  | 
| Simulated Sheeps Wool  | 0.060  | 1360  | 198  | 
| Wool Felt Underlay  | 0.040  | 1360  | 160  | 
| Cellular Rubber Underlay  | 0.100  | 1360  | 400  | 
| Synthetic Carpet  | 0.060  | 2500  | 160  | 
|  |  |  |  | 
| Concrete  |  |  |  | 
| Aerated Concrete Slab  | 0.160  | 840  | 500  | 
| Cast Concrete (Dense)  | 1.400  | 840  | 2100  | 
| Cast Concrete (Lightweight)  | 0.380  | 1000  | 1200  | 
| Cast Concrete  | 1.130  | 1000  | 2000  | 
| Concrete Block (Heavyweight)  | 1.630  | 1000  | 2300  | 
| Concrete Block (Medium)  | 0.510  | 1000  | 1400  | 
| Concrete Block (Lightweight)  | 0.190  | 1000  | 600  | 
| Concrete Paviour  | 0.960  | 840  | 2000  | 
| Foam Slag  | 0.250  | 960  | 1040  | 
| Aerated Concrete Block  | 0.240  | 1000  | 750  | 
| Refactory Insulating Concrete  | 0.250  | 837  | 1050  | 
| Vermiculite Aggregate  | 0.170  | 837  | 450  | 
| Concrete Tiles  | 1.100  | 837  | 2100  | 
| Heavyweight Concrete Dried Aggregate – CC01  | 1.310  | 837  | 2243  | 
| Heavyweight Concrete Undried Aggregate – CC11  | 1.802  | 837  | 2243  | 
| Heavyweight Concrete Undried Aggregate – HF-C12  | 1.730  | 837  | 2243  | 
| Lightweight Concrete – 80 Lbs – CC21  | 0.36  | 837  | 1282  | 
| Lightweight Concrete – 30 Lbs – CC31  | 0.130  | 837  | 481  | 
| Lightweight Concrete – 40 Lbs – HF-C14  | 0.173  | 837  | 641  | 
| Lightweight Concrete – HF-C2  | 0.380  | 837  | 609  | 
| Heavyweight Concrete Block - Hollow – CB01  | 0.812  | 837  | 1618  | 
| Heavyweight Concrete Block - Concrete-Filled – CB02  | 1.310  | 837  | 2234  | 
| Heavyweight Concrete Block - Perlite-Filled – CB03  | 0.384  | 837  | 1650  | 
| Heavyweight Concrete Block – Part-Filled Concrete – CB04  | 1.011  | 837  | 1826  | 
| Heavyweight Concrete Block – Concrete and Perlite-Filled – CB05  | 0.825  | 837  | 1842  | 
| Mediumweight Concrete Block - Hollow – CB21  | 0.519  | 837  | 1218  | 
| Mediumweight Concrete Block - Concrete-Filled – CB22  | 0.771  | 837  | 1842  | 
| Mediumweight Concrete Block - Perlite-Filled – CB23  | 0.262  | 837  | 1250  | 
| Mediumweight Concrete Block – Part-Filled Concrete – CB24  | 0.572  | 837  | 1426  | 
| Mediumweight Concrete Block – Concrete and Perlite-Filled – CB25  | 0.431  | 837  | 1442  | 
| Lightweight Concrete Block - Hollow – CB41  | 0.384  | 837  | 1041  | 
| Lightweight Concrete Block - Concrete-Filled – CB42  | 0.639  | 837  | 1666  | 
| Lightweight Concrete Block - Perlite-Filled – CB43  | 0.220  | 837  | 1073  | 
| Lightweight Concrete Block – Part-Filled Concrete – CB44  | 0.486  | 837  | 1250  | 
| Lightweight Concrete Block – Concrete and Perlite-Filled – CB45  | 0.360  | 837  | 1266  | 
|  |  |  |  | 
|  |  |  |  | 
| Gravels, Beddings Etc.  |  |  |  | 
| Stone Chippings  | 0.960  | 1000  | 1800  | 
| Gravel  | 0.360  | 840  | 1840  | 
| Gravel-Based Soil  | 0.520  | 184  | 2050  | 
| Tile Bedding  | 1.400  | 650  | 2100  | 
|  |  |  |  | 
|  |  |  |  | 
| Insulating Materials  |  |  |  | 
| Eps Slab  | 0.035  | 1400  | 25  | 
| Silicon  | 0.180  | 1004  | 700  | 
| Glass-Fibre Quilt  | 0.040  | 840  | 12  | 
| Glass-Fibre Slab  | 0.035  | 1000  | 25  | 
| Mineral Fibre Slab  | 0.035  | 1000  | 30  | 
| Phenolic Foam  | 0.040  | 1400  | 30  | 
| Polyurethane Board  | 0.025  | 1400  | 30  | 
| Uf Foam  | 0.040  | 1400  | 10  | 
| Wood Wool Slab  | 0.100  | 1000  | 500  | 
| Vermiculite Insulating Brick  | 0.270  | 837  | 700  | 
| Refactory Insulating Concrete  | 0.250  | 837  | 1050  | 
| Glasswool  | 0.040  | 670  | 200  | 
| Thermalite - High Strength  | 0.190  | 1050  | 760  | 
| Thermalite 'Turbo'  | 0.110  | 1050  | 480  | 
| Thermalite 'Shield'/'Smooth Face'  | 0.170  | 1050  | 650  | 
| Siporex  | 0.120  | 1004  | 550  | 
| P.V.C  | 0.160  | 1004  | 1379  | 
| Polystyrene  | 0.030  | 1380  | 25  | 
| Hard Rubber  | 0.150  | 1000  | 1200  | 
| Cratherm Board  | 0.050  | 837  | 176  | 
| Uf Foam Two  | 0.030  | 1764  | 30  | 
| Uf Foam Two  | 0.030  | 1764  | 30  | 
| Lightweight Metallic Cladding  | 0.290  | 1000  | 1250  | 
| Dense Eps Slab Insulation (styrofoam)  | 0.025  | 1400  | 30  | 
| Cellular Glass  | 0.050  | 800  | 136  | 
| Glass-Fibre – Organic Bonded  | 0.036  | 1000  | 100  | 
| Expanded Perlite – Organic Bonded  | 0.052  | 1300  | 16  | 
| Expanded Rubber - Rigid  | 0.032  | 1700  | 72  | 
| Cellular Polyurethane  | 0.023  | 1600  | 24  | 
| Cellular Polyisocyanurate  | 0.023  | 900  | 32  | 
| Cellular Phenolic – Mineral Fibre With Resin Binder  | 0.042  | 700  | 240  | 
| Cement Fibre Slab – Shredded Wood With Magnesia Oxysulfide Cement Binder  | 0.082  | 1300  | 350  | 
| Vermiculite - Exfoliated  | 0.068  | 1300  | 120  | 
| Felt & Membrane – Felt – HF-E3  | 0.190  | 1674  | 1121  | 
| Felt & Membrane – Finish – HF-A6  | 0.415  | 1088  | 1249  | 
| Mineral Wool/Fibre – Batt – IN01  | 0.043  | 837  | 10  | 
| Mineral Wool/Fibre – Fill – IN11  | 0.046  | 837  | 10  | 
| Mineral Wool/Fibre – Fill – IN12  | 0.046  | 837  | 11  | 
| Cellulose Fill – IN13  | 0.039  | 1381  | 48  | 
| Insulation Board – HF-B2  | 0.043  | 1381  | 48  | 
| Insulation Board – HF-B5  | 0.043  | 837  | 32  | 
| Preformed Mineral Board – IN21  | 0.042  | 711  | 240  | 
| Expanded Polystyrene – IN31  | 0.035  | 1213  | 29  | 
| Expanded Polyurethane – IN41  | 0.023  | 1590  | 24  | 
| Urea Formaldehyde – IN51  | 0.035  | 1255  | 11  | 
| Insulation Board Sheathing – IN61  | 0.055  | 1297  | 288  | 
| Insulation Board Shingle Backer – IN63  | 0.058  | 1297  | 288  | 
| Insulation Board Nail Base Sheathing – IN64  | 0.064  | 1297  | 400  | 
| Preformed Roof Insulation – IN71  | 0.052  | 837  | 256  | 
|  |  |  |  | 
|  |  |  |  | 
| Metal  |  |  |  | 
| Steel  | 50.000  | 480  | 7800  | 
| Copper  | 200.000  | 418  | 8900  | 
| Aluminium  | 160.000  | 896  | 2800  | 
| Lightweight Metallic Cladding  | 0.290  | 1000  | 1250  | 
| Steel Siding – HF-A3  | 44.970  | 418  | 7690  | 
|  |  |  |  | 
|  |  |  |  | 
| Plaster  |  |  |  | 
| Plaster (Dense)  | 0.500  | 1000  | 1300  | 
| Plaster (Lightweight)  | 0.160  | 1000  | 600  | 
| Gypsum Plasterboard  | 0.160  | 840  | 950  | 
| Perlite Plasterboard  | 0.180  | 837  | 800  | 
| Gypsum Plastering  | 0.420  | 837  | 1200  | 
| Perlite Plastering  | 0.080  | 837  | 400  | 
| Vermiculite Plastering  | 0.200  | 837  | 720  | 
| Plaster Ceiling Tiles  | 0.380  | 840  | 1120  | 
| Cement Plaster  | 0.720  | 800  | 1860  | 
| Perlite Plaster  | 0.220  | 1300  | 720  | 
| Perlite Plaster – Sand Aggregate  | 0.810  | 800  | 1680  | 
| Cement Plaster – With Sand Aggregate – CM03  | 0.721  | 837  | 1858  | 
| Gypsum/ Plaster Board – HF-E1  | 0.160  | 837  | 801  | 
| Gypsum Plaster Lightweight Aggregate– GP04  | 0.230  | 837  | 721  | 
| Gypsum Plaster – Sand Aggregate– GP06  | 0.819  | 837  | 1682  | 
|  |  |  |  | 
|  |  |  |  | 
| Screeds And Renders  |  |  |  | 
| External Rendering  | 0.500  | 1000  | 1300  | 
| Screed  | 0.410  | 840  | 1200  | 
| Granolithic Render/Screed  | 0.870  | 837  | 2085  | 
| Stucco – HF-A1  | 0.721  | 837  | 2659  | 
|  |  |  |  | 
|  |  |  |  | 
| Sands, Stones And Soils  |  |  |  | 
| Stone Chippings  | 0.960  | 1000  | 1800  | 
| Gravel  | 0.360  | 840  | 1840  | 
| Gravel-Based Soil  | 0.520  | 184  | 2050  | 
| Sandstone  | 1.830  | 712  | 2200  | 
| Granite (Red)  | 2.900  | 900  | 2650  | 
| Marble (White)  | 2.770  | 802  | 2600  | 
| Cultivated Sandy Soil 12.5%D.W. Moisture  | 1.790  | 1190  | 1800  | 
| Cultivated Sandy Soil 25.0%D.W. Moisture  | 2.220  | 1480  | 2000  | 
| Cultivated Clay Soil 12.5%D.W. Moisture  | 1.180  | 1250  | 1800  | 
| Cultivated Clay Soil 25.0%D.W. Moisture  | 1.590  | 1550  | 2000  | 
| Cultivated Peat Soil 133%D.W. Moisture  | 0.290  | 3300  | 700  | 
| Cultivated Peat Soil 366%D.W. Moisture  | 0.500  | 3650  | 1100  | 
| Dry Limestone Sub-Soil  | 1.490  | 840  | 2180  | 
| London Clay  | 1.410  | 1000  | 1900  | 
| Soil  | 1.729  | 837  | 1842  | 
| Stone – ST01  | 1.802  | 837  | 2243  | 
| Stone – HF-A3  | 1.435  | 1674  | 881  | 
| Terrazzo – TZ01  | 1.802  | 837  | 2243  | 
|  |  |  |  | 
|  |  |  |  | 
| Tiles  |  |  |  | 
| Clay Tile  | 0.840  | 800  | 1900  | 
| Concrete Tiles  | 1.100  | 837  | 2100  | 
| Slate Tiles  | 2.000  | 753  | 2700  | 
| Plastic Tiles  | 0.500  | 837  | 1950  | 
| Rubber Tiles  | 0.300  | 2000  | 1600  | 
| Cork Tiles  | 0.080  | 1800  | 530  | 
| Asphalt/Asbestos Tiles  | 0.550  | 837  | 1900  | 
| P.V.C./Asbestos Tiles  | 0.850  | 837  | 2000  | 
| Ceiling Tiles  | 0.056  | 1000  | 380  | 
| Plaster Ceiling Tiles  | 0.380  | 840  | 1120  | 
| Lightweight Metallic Cladding  | 0.290  | 1000  | 1250  | 
| Acoustical Tile – Mineral Fibreboard  | 0.050  | 800  | 290  | 
| Acoustic Tile  - AC01  | 0.057  | 1339  | 288  | 
| Acoustic Tile – HF-E5  | 0.061  | 2142  | 480  | 
| Hollow Clay Tile – 1 Cell – CT01  | 0.498  | 837  | 1121  | 
| Hollow Clay Tile – 2 Cells – CT03  | 0.571  | 837  | 1121  | 
| Hollow Clay Tile – 3 Cells – CT06  | 0.692  | 837  | 1121  | 
| Clay Tile – HF-C1  | 0.571  | 837  | 1121  | 
| Paver – Clay Tile – CT11  | 1.802  | 837  | 1922  | 
| Slate – SL01  | 1.442  | 1464  | 1602  | 
|  |  |  |  | 
|  |  |  |  | 
| Timber  |  |  |  | 
| Timber Flooring  | 0.140  | 1200  | 650  | 
| Plywood (Lightweight)  | 0.150  | 2500  | 560  | 
| Plywood (Heavyweight)  | 0.150  | 1420  | 700  | 
| Wood Blocks  | 0.140  | 1200  | 650  | 
| Wood Wool Slab  | 0.100  | 1000  | 500  | 
| Hardboard (Medium)  | 0.080  | 2000  | 600  | 
| Hardboard (Standard)  | 0.130  | 2000  | 900  | 
| Pine (20% Moist)  | 0.140  | 2720  | 419  | 
| Cork Board  | 0.040  | 1888  | 160  | 
| Chipboard  | 0.150  | 2093  | 800  | 
| Weatherboard  | 0.140  | 2000  | 650  | 
| Oak (Radial)  | 0.190  | 2390  | 700  | 
| Cork Tiles  | 0.080  | 1800  | 530  | 
| Plywood – PW01  | 0.115  | 1213  | 545  | 
| Soft Wood – WD01  | 0.115  | 1381  | 513  | 
| Hard Wood – WD11  | 0.158  | 1255  | 721  | 
| Wood – HF-B7  | 0.121  | 837  | 593  | 
| Plywood – Douglas Fir  | 0.120  | 1200  | 540  | 
| Shingle Wood – WS01  | 0.115  | 1255  | 513  | 
| Description  | Refl  | Absorp  | Trans  | Refr  | 
|  |  |  |  |  | 
| Clear Float 4mm  | 0.07  | 0.11  | 0.82  | 1.526  | 
| Clear Float 6mm  | 0.07  | 0.15  | 0.78  | 1.526  | 
| Clear Float 10mm  | 0.07  | 0.23  | 0.7  | 1.526  | 
| Clear Float 12mm  | 0.06  | 0.27  | 0.67  | 1.526  | 
| 'Spectrafloat' 6mm 51/65 (Bronze)  | 0.1  | 0.36  | 0.54  | 1.526  | 
| 'Antisun' Float 6mm 72/62 (Green)  | 0.05  | 0.49  | 0.46  | 1.526  | 
| 'Antisun' Float 4mm 55/68 (Grey)  | 0.05  | 0.4  | 0.55  | 1.526  | 
| 'Antisun' Float 6mm 42/60 (Grey)  | 0.05  | 0.53  | 0.42  | 1.526  | 
| 'Antisun' Float 10mm 25/49 (Grey)  | 0.04  | 0.71  | 0.25  | 1.526  | 
| 'Antisun' Float 12mm 19/45 (Grey)  | 0.04  | 0.77  | 0.19  | 1.526  | 
| 'Antisun' Float 4mm 61/70 (Bronze)  | 0.06  | 0.36  | 0.58  | 1.526  | 
| 'Antisun' Float 6mm 50/62 (Bronze)  | 0.05  | 0.49  | 0.46  | 1.526  | 
| 'Antisun' Float 10mm 33/51 (Bronze)  | 0.04  | 0.67  | 0.29  | 1.526  | 
| 'Antisun' Float 12mm 27/47 (Bronze)  | 0.04  | 0.73  | 0.23  | 1.526  | 
| 'Antisun' Float  6mm 54/62 (Blue)  | 0.05  | 0.49  | 0.46  | 1.526  | 
| Reflectafloat 6mm 35/53 (Silver)  | 0.28  | 0.29  | 0.43  | 1.526  | 
| 'Suncool' Classic 6mm 20/33 (Blue)  | 0.21  | 0.64  | 0.15  | 1.526  | 
| 'Suncool' Classic 6mm 30/39 (Blue)  | 0.18  | 0.61  | 0.21  | 1.526  | 
| 'Suncool' Classic 6mm 40/50 (Blue)  | 0.1  | 0.58  | 0.32  | 1.526  | 
| 'Suncool' Classic 6mm 10/24 (Bronze)  | 0.21  | 0.73  | 0.06  | 1.526  | 
| 'Suncool' Classic 6mm 10/23 (Silver)  | 0.32  | 0.6  | 0.08  | 1.526  | 
| 'Suncool' Classic 6mm 20/34 (Silver)  | 0.18  | 0.66  | 0.16  | 1.526  | 
| 'Suncool' Classic 10mm 10/33 (Blue)  | 0.19  | 0.66  | 0.15  | 1.526  | 
| 'Suncool' Classic 10mm 30/38 (Blue)  | 0.17  | 0.63  | 0.2  | 1.526  | 
| 'Suncool' Classic 10mm 40/49 (Blue)  | 0.09  | 0.6  | 0.31  | 1.526  | 
| 'Suncool' Classic 10mm 10/24 (Bronze)  | 0.19  | 0.76  | 0.05  | 1.526  | 
| 'Suncool' Classic 10mm 10/23 (Silver)  | 0.3  | 0.62  | 0.08  | 1.526  | 
| 'Suncool' Classic 10mm 20/34 (Silver)  | 0.16  | 0.69  | 0.15  | 1.526  | 
| 'Suncool' Classic  6mm 20/34 (Silver)  | 0.18  | 0.66  | 0.16  | 1.526  | 
| 'Suncool' Classic 10mm 20/33 (Blue)  | 0.19  | 0.66  | 0.15  | 1.526  | 
| Stopsol 4mm (Clear)  | 0.25  | 0.22  | 0.53  | 1.526  | 
| Stopsol 5mm (Clear)  | 0.25  | 0.24  | 0.51  | 1.526  | 
| Stopsol 6mm (Clear)  | 0.25  | 0.25  | 0.5  | 1.526  | 
| Stopsol 8mm (Clear)  | 0.25  | 0.28  | 0.47  | 1.526  | 
| Stopsol 10mm (Clear)  | 0.24  | 0.31  | 0.45  | 1.526  | 
| Stopsol 4mm (Bronze)  | 0.27  | 0.38  | 0.35  | 1.526  | 
| Stopsol 5mm (Bronze)  | 0.27  | 0.41  | 0.32  | 1.526  | 
| Stopsol 6mm (Bronze)  | 0.26  | 0.45  | 0.29  | 1.526  | 
| Stopsol 8mm (Bronze)  | 0.26  | 0.51  | 0.23  | 1.526  | 
| Stopsol 10mm (Bronze)  | 0.26  | 0.56  | 0.18  | 1.526  | 
| Stopsol 6mm (Silver)  | 0.2  | 0.37  | 0.43  | 1.526  | 
| Kappafloat 4mm (Champagne)  | 0.17  | 0.22  | 0.61  | 1.526  | 
| Kappafloat 4mm (Neutral)  | 0.2  | 0.14  | 0.66  | 1.526  | 
| Kappafloat 6mm (Champagne)  | 0.16  | 0.26  | 0.58  | 1.526  | 
| Kappafloat 6mm (Neutral)  | 0.2  | 0.17  | 0.63  | 1.526  | 
| Saflex Blue-Green (Light) 5.4mm  | 0.07  | 0.19  | 0.74  | 1.526  | 
| Saflex Blue-Grey (Light) 5.4mm  | 0.06  | 0.4  | 0.54  | 1.526  | 
| Saflex Blue-Grey (Medium) 6.2mm  | 0.05  | 0.59  | 0.36  | 1.526  | 
| Saflex Bronze 5.4mm  | 0.06  | 0.41  | 0.53  | 1.526  | 
| Saflex Bronze (Light) 5.4mm  | 0.06  | 0.37  | 0.57  | 1.526  | 
| Saflex Bronze (Medium) 5.7mm  | 0.05  | 0.56  | 0.39  | 1.526  | 
| Saflex Green-Blue (Light) 5.3mm  | 0.07  | 0.18  | 0.75  | 1.526  | 
| Saflex Grey 5.4mm  | 0.05  | 0.51  | 0.44  | 1.526  | 
| Saflex Grey-Green (Light) 5.4mm  | 0.06  | 0.42  | 0.52  | 1.526  | 
| Saflex Marine Blue (Light) 5.3mm  | 0.06  | 0.35  | 0.59  | 1.526  | 
| Saflex Marine Blue (Medium) 5.3mm  | 0.05  | 0.56  | 0.39  | 1.526  | 
| Saflex Pink (Light) 6.3mm  | 0.06  | 0.31  | 0.63  | 1.526  | 
| Saflex Translucent White 6.1mm  | 0.06  | 0.37  | 0.57  | 1.526  | 
| Saflex Shadowlite Smoke Brown (L) 5.4mm  | 0.06  | 0.39  | 0.55  | 1.526  | 
| Saflex Shadowlite Smoke Brown (M) 5.3mm  | 0.05  | 0.67  | 0.28  | 1.526  | 
| Saflex Shadowlite Smoke Brown (D) 6.3mm  | 0.04  | 0.86  | 0.1  | 1.526  | 
| Polycarbonate 3mm Clear  | 0.09  | 0.09  | 0.82  | 1.6  | 
| Acrylic 3mm Clear  | 0.09  | 0.06  | 0.85  | 1.49  | 
| Luxguard 6mm (Bright Silver) Cs-14  | 0.27  | 0.61  | 0.12  | 1.526  | 
| Luxguard 6mm (Bright Silver) Cs-20  | 0.22  | 0.61  | 0.17  | 1.526  | 
| Luxguard 6mm (Bright Silver) Cs-35  | 0.14  | 0.54  | 0.32  | 1.526  | 
| Luxguard 6mm (Pewter) Cp-14  | 0.2  | 0.66  | 0.14  | 1.526  | 
| Luxguard 6mm (Pewter) Cp-20  | 0.16  | 0.65  | 0.19  | 1.526  | 
| Luxguard 6mm (Pewter) Cp-35  | 0.09  | 0.58  | 0.33  | 1.526  | 
| Luxguard 6mm (Bronze) Cb-14  | 0.18  | 0.69  | 0.13  | 1.526  | 
| Luxguard 6mm (Bronze) Cb-20  | 0.13  | 0.68  | 0.19  | 1.526  | 
| Luxguard 6mm (Bronze) Cb-35  | 0.08  | 0.6  | 0.32  | 1.526  | 
| Luxguard 6mm (Royal Blue) Cr-14  | 0.17  | 0.7  | 0.13  | 1.526  | 
| Luxguard 6mm (Royal Blue) Cr-20  | 0.12  | 0.69  | 0.19  | 1.526  | 
| Luxguard 6mm (Royal Blue) Cr-35  | 0.07  | 0.61  | 0.32  | 1.526  | 
| Thermoclear 8mm Polycarbonate Sheeting  | 0.05  | 0.8  | 0.15  | 1.59  | 
| Thermoclear 16mm Polycarbonate Sheeting  | 0.08  | 0.7  | 0.22  | 1.59  | 
| Perfectly Clear Glazing Material  | 0  | 0  | 1  | 1  |