Part L2 (2010) VE-SBEM Results

 
This tab on the dialog at the lower edge of the VE Compliance screen allows you to view the results of Part L2 (2010) calculations.
 
Compliance:
Building Emissions Rate (BER)
The Building Emissions Rate (kgCO2/m2) calculated for the actual building.
 
Notional Building Emissions Rate
The Building Emissions Rate (kgCO2/m2) calculated for the notional building (Cnotional).
 
Target Emissions Rate (TER)
The 2010 Target Emission Rate is the 2010 Notional building emission rate.
 
Did the analysis pass the CO2 emissions rating?
The pass/fail result for Criterion 1. ‘YES’ if BER<TER, ‘NO’ otherwise.
 
View Compliance Doc
Click on this button to view the Compliance Document generated by BRUKL using inputs from the actual and notional building simulations, together with the data entered in Building & System Data and the results of the Criterion 2 U-value checks and Criterion 3 Solar Gain checks
 
Calculation details
Click on this button to view the calculation data using inputs from the SBEM calculations, together with the data entered in Building & System Data and the results of the Criterion 2 U-value checks.
 
Extra output files
Two further output files are copied to the project’s Regs\Part L2\SBEM\BRUKL folder and may be of interest. Both are in comma-separated format.
·       <buildingname>_not_sim.csv      The calculation details for the Notional building
·       <buildingname>_dr.csv                The data reflection report for the Actual building
 
 
 
EPC:
 
Part L TER
The Target Building Emissions Rate, derived from the Notional Building Emissions Rate (Cnotional)
 
Standard
The Standard Emission Rate (SER), calculated as the Reference Emissions Rate (calculated by SBEM for the Reference Building during an EPC calculation) multiplied by an improvement factor of 0.765.
Cstandard = Creference x (1 – 0.235)
 
Actual BER
The Building Emissions Rate calculated for the Actual Building.
 
Asset Rating
The ratio of the Actual emission to the Standard emission, where 50 corresponds to a 1:1 ratio:
EPC Rating = (Cactual / Cstandard ) × 50
The band letter and colour corresponding to this (as also shown on the EPC) is shown under the Actual emission figure.
The Part L and Typical bands are also shown, based on similar formulae (the numerical rating values are shown on the EPC).
Part LRating = (CTER / Cstandard ) × 50
 
View EPC
Click on this button to view the Energy Performance Certificate PDF.
 
View Recommendation
Click on this button to view the Recommendations Report PDF.
 
Extra Output Files
Two further output files are copied to the project’s Regs\SBEM\EPC folder and may be of interest. Both are in comma-separated format.
·       <buildingname>_not_sim.csv                   The calculation details for the Notional building
·       <buildingname>_dr.csv                The data reflection report for the Actual building
In this folder you will also see a secondary, more detailed, Recommendations Report PDF and the XML file to be lodged in official databases.