|
chillers
|
|
|
condenser_water_loop
|
|
|
distribution_loss
|
(float) Distribution loss
|
|
independent_secondary_loop_enabled
|
(bool) Whether an independent secondary loop is enabled
|
|
oversizing_factor
|
(float) Oversizing factor
|
|
primary_chilled_water_demand_side_load_fraction_high_threshold
|
(float) Higher threshold for primary chilled water demand side load fraction
|
|
primary_chilled_water_demand_side_load_fraction_low_threshold
|
(float) Lower threshold for primary chilled water demand side load fraction
|
|
primary_chilled_water_supply_temp_high_threshold
|
(float) Higher threshold for primary chilled water supply temperature
|
|
primary_chilled_water_supply_temp_low_threshold
|
(float) Lower threshold for primary chilled water supply temperature
|
|
primary_chilled_water_supply_temp_reset_type
|
(int) Primary chilled water supply temperature reset type
|
|
primary_chilled_water_supply_temperature
|
(float) Primary chilled water supply temperature
|
|
primary_chilled_water_temperature_difference
|
(float) Primary chilled water temperature difference
|
|
primary_circuit_using_dedicated_chiller_pumps
|
(float) Primary circuit using dedicated chiller pumps
|
|
primary_outdoor_dew_point_temp_high_threshold
|
(float) Higher threshold for primary outdoor dew point temperature
|
|
primary_outdoor_dew_point_temp_low_threshold
|
(float) Lower threshold for primary outdoor dew point temperature
|
|
primary_outdoor_dry_bulb_temp_high_threshold
|
(float) Higher threshold for primary outdoor dry bulb temperature
|
|
primary_outdoor_dry_bulb_temp_low_threshold
|
(float) Lower threshold for primary outdoor dry bulb temperature
|
|
secondary_chilled_water_demand_side_load_fraction_high_threshold
|
(float) Higher threshold for secondary chilled water demand side load fraction
|
|
secondary_chilled_water_demand_side_load_fraction_low_threshold
|
(float) Lower threshold for secondary chilled water demand side load fraction
|
|
secondary_chilled_water_supply_temp_high_threshold
|
(float) Secondary chilled water supply temp high threshold
|
|
secondary_chilled_water_supply_temp_low_threshold
|
(float) Lower threshold for secondary chilled water supply temperature
|
|
secondary_chilled_water_supply_temp_reset_type
|
(int) Secondary chilled water supply temperature reset type
|
|
secondary_chilled_water_supply_temperature
|
(float) Secondary chilled water supply temperature
|
|
secondary_chilled_water_temperature_difference
|
(float) Secondary chilled water temperature difference
|
|
secondary_outdoor_dew_point_temp_high_threshold
|
(float) Higher threshold for secondary outdoor dew point temperature
|
|
secondary_outdoor_dew_point_temp_low_threshold
|
(float) Lower threshold for secondary outdoor dew point temperature
|
|
secondary_outdoor_dry_bulb_temp_high_threshold
|
(float) Higher threshold for secondary outdoor dry bulb temperature
|
|
secondary_outdoor_dry_bulb_temp_low_threshold
|
(float) Lower threshold for secondary outdoor dry bulb temperature
|
|
thermal_storage_loop
|
|