×
Menu
Index

Attributes Defined Here

 
autosize_mode
(int) Whether autosize mode is enabled. 1 if so, 0 otherwise.
design_heating_cooling_load
(float) Design heating and cooling load
design_room_air_temp
(float) Design room air temperature
design_room_radiant_temp
(float) Design room radiant temperature
design_water_delta_t
(float) Design water delta T
error_code
(int) Error code
flow_for_max_control_signal
(float) Flow for maximum control signal
flow_for_min_control_signal
(float) Flow for minimum control signal
flow_max_change_per_time_step
(float) Flow max change per time step
flow_midband
(float) Flow midband
flow_midband_mode
(int) Flow midband mode
flow_midband_profile_id
(string) Flow midband profile ID
flow_proportional_bandwidth
(float) Flow proportional bandwidth
flow_proportional_control
(int) Whether it is flow proportional control. 1 if so, 0 otherwise.
flow_proportional_controller_id
(string) Flow proportional controller ID
flow_proportional_sensed_variable
(int) Flow proportional sensed variable
flow_proportional_sensor_body_index
(int) Flow proportional sensor body index
flow_proportional_sensor_location
(int) Flow proportional sensor location
flow_proportional_sensor_room_id
(string) Flow proportional sensor room ID
model_id
(string) Model ID
number_of_units
(float) Number of units
oversizing_factor
(float) Oversizing factor
prop_flow_orientation
(float) Proportional flow orientation
prop_flow_radiant_fraction
(float) Proportional flow radiant fraction
prop_flow_slope
(float) Proportional flow slope
prop_temp_orientation
(float) Proportional temperature orientation
prop_temp_radiant_fraction
(float) Proportional temperature radiant fraction
prop_temp_slope
(float) Proportional temperature slope
temp_for_max_control_signal
(float) Temperature for maximum control signal
temp_for_min_control_signal
(float) Temperature for minimum control signal
temp_max_change_per_time_step
(float) Temperature maximum change per time step
temp_midband
(float) Temperature midband
temp_midband_mode
(int) Temperature midband mode
temp_midband_profile_id
(string) Temperature midband profile ID
temp_proportional_bandwidth
(float) Temperature proportional bandwidth
temp_proportional_control
(int) Whether it is temperature proportional control. 1 is so, 0 otherwise.
temp_proportional_controller_id
(string) Temperature proportional controller ID
temp_proportional_sensed_variable
(int) Temperature proportional sensed variable
temp_proportional_sensor_body_index
(int) Temperature proportional sensor body index
temp_proportional_sensor_location
(int) Temperature proportional sensor location
temp_proportional_sensor_room_id
(string) Temperature proportional sensor  ID
thermal_source_id
(string) Thermal source ID
water_loop_supply_temperature_used
(int) Whether water loop supply temperature is used. 1 is so, 0 otherwise.