Methods Defined Here

 
get_options( ) -> dictionary
Get the simulation options currently in effect.  Return type is a dictionary with the current options.  Available options are:
 
start_day
(int) 1-31
start_month
(int) 1-12
end_day
(int) 1-31
end_month
(int) 1-12
simulation_timestep
(int) 0=1, 1=2, 2=6, 3=10, 4=30 minutes
reporting_interval
(int) 0=6, 1=10, 2=30, 3=60 minutes
preconditioning_days
(int) 0-365
results_filename
(string) file will be located in Vista folder
Suncast
(Boolean) setting this to True will run Suncast if required
suncast_filename
(string) shading file filename
macroflo
(Boolean) setting this to True requires a macroflo input file (.mfo) to be present. Setting this to True is required for opening-level results
HVAC
(Boolean) include HVAC
HVAC_filename
(string) HVAC network filename, used if HVAC is True
radiance
(Boolean) setting this to True will automatically run Radiance if queueToTasks is True when running simulations.  It will not run automatically if a blocking simulation is run, in which case an existing Radiance results file (.ill) is required
aux_ventilation
(Boolean) defaults to True
nat_ventilation
(Boolean) defaults to True
 
 
 
Output options.  These correspond to the Apache Simulation Output Options dialog and apply to all rooms:
 
output_standard_outputs
(Boolean) defaults to True
output_sensible_internal_gains
(Boolean) defaults to True
output_latent_internal_gains
(Boolean) defaults to False
output_latent_ventilation_gains
(Boolean) defaults to False
output_conduction_gains
(Boolean) defaults to False
output_HVAC_systems
(Boolean) defaults to True
output_HVAC_components
(Boolean) defaults to False
 
Detailed output options.  These correspond to the Apache Simulation Output Options dialog and apply only to the rooms indicated in detailed_rooms.  Note that detailed output per room can significantly increase APS file size if a large number of rooms are included.
 
detailed_rooms
(list of strings) each string holds a room ID
detailed_microflo
(Boolean) defaults to True
detailed_standard_outputs
(Boolean) defaults to True
detailed_sensible_internal_gains
(Boolean) defaults to True
detailed_latent_internal_gains
(Boolean) defaults to True
detailed_latent_ventilation_gains
(Boolean) defaults to True
detailed_convective_gains
(Boolean) defaults to True
detailed_surface_temps
(Boolean) defaults to True.  Setting this for a room enables Surface level results for that room
detailed_external_solar
(Boolean) defaults to False.  Setting this for a room enables Surface level results for that room
detailed_internal_solar
(Boolean) defaults to False.  Setting this for a room enables Surface level results for that room
detailed_conduction_gains
(Boolean) defaults to False
detailed_HVAC_systems
(Boolean) defaults to True
 
Note that setting Suncast and Radiance to True will only auto-run suncast when using batch operation. When using the blocking run, suncast and radiance will not be automatically run when set to True, but if corresponding data files are available (shd and ill files) they will be used in simulation. Absence of data files may cause simulation to fail.
 
reset_options( ) -> Boolean
Reset the simulation options file to defaults. Returns True if the options file was saved successfully.
 
run_compliance_simulation () -> Bool
    Run compliance simulation with the currently active settings. Parallel Simulation Manager (BETA) will
    be used. A return value of true indicates that simulation was run / queued, false indicates error.
 
run_loads_sizing()
    Run a Loads and Sizing simulation
 
run_simulation( queueToTasks = False ) -> Boolean
Run Apache thermal simulation with the currently active settings.  If the queueToTasks parameter is True, Parallel Simulation Manager (BETA) will be used (if licensed and activated).  The task will be queued and script operation will continue immediately.  When not using queueing, the simulation will run and the VE is blocked until simulation is complete.  A return value of true indicates that simulation was run / queued, false indicates error.
 
set_hvac_network(network_name)
Set the HVAC network.
 
set_options( {options} ) -> Boolean
Set and save simulation options.  These options will be used for the subsequent simulation run.  See get_options() for details on available options (keywords).  Returns True if the options file was saved successfully.
 
Note: the options to be set can be supplied either as a dict or as keyword parameters.
 
show_simulation_dialog( ) -> Boolean
Show the Apache Simulation dialog.  Returns True if dialog was shown and simulation was run.