4.9.7. ADVANCED ENVELOPE – Buildings (ASHRAE Template only)
Advanced – Envelope attribute provides a list of building envelope data including wall, door, window, ceiling, floor and roof with the standard U-values.
Ceiling - constriction specification of the building ceiling with respect to its thickness, main building material, false ceiling, insulation and thermal transmittance can be selected here.
Figure 4-45 Building Query Tool - Ceiling
Door - construction specification for external/ internal doors with respect to its material can be selected here.
Figure 4-46 Building Query Tool - Door
Ext wall - construction specifications of external wall with respect to its compliance rating, main building material, its thickness, finish (plaster), sound insulation and total thermal transmittance (U value) of the external building fabric can be selected here.
Figure 4-47 Building Query Tool – Ext Wall
Ext window - construction specification of external window with respect to its thickness, layers of glazing (single/double), shading coefficient (SC), solar heat gain coefficient (SHGC) and total thermal transmittance (U value) of the glazing can be selected here.
Figure 4-48 Building Query Tool – Ext. Window
Ground floor - construction specification of ground floor with respect to its compliance rating, main building material, extent of insulation, thermal transmittance (U value) can be selected here
Figure 4-49 Building Query Tool – Ground floor
Int. wall - construction specification of internal wall with respect to its main building material, its thickness, finish (plaster), sound insulation and total thermal transmittance (U value) of the external building fabric can be selected here
Figure 4-50 Building Query Tool – Int. wall
Int. window - construction specification of internal window with respect to its thickness, layers of glazing (single/double), shading coefficient (SC), solar heat gain coefficient (SHGC) and total thermal transmittance (U value) of the glazing can be selected here.
Figure 4-51 Building Query Tool – Int. window
Roof - construction specification of Roof with respect to its compliance rating, main roofing material, thickness, roofing type (flat/sloping), level of insulation, weather proofing and thermal transmittance (U value) can be selected here.
Figure 4-52 Building Query Tool – Roof
Roof Light - construction specification of roof light with respect to its thickness, layers of glazing (single/double), shading coefficient (SC) , solar heat gain coefficient (SHGC) and total thermal transmittance (U value) of the glazing can be selected here.
Figure 4-53 Building Query Tool – Roof light