4.9.16. CSV Export

Editing a model using CSV export and import
The CSV export and import process allows to edit a large number of attributes over a large number of objects.
To do so, the objects that need to be edited should be exported to csv file with the attributes that need to be modified.
Extensions > IES iCD > Import/Export > Export CSV
1.      Select the objects that needs to be exported with the object filter and click Show.
2.      Select the different attributes to export in the CSV file.
3.      Click Export. (Note, if the user is exporting simulated data it is important to check the Aggregate results (export only) box to get the data as annual total. If this is not checked, the results are export as set of 12 monthly values).
4.      Open the CSV file in the MS. Excel and edit the data’s based on the requirements.
 
Figure 4-75 CSV Export dialogue box
 
Figure 4- CSV Export options
Export options
When exporting a CSV files, some export options are preselected (Export object identifier column and export units with property names), these are the ones that will be used most often. However, there are a few other options that the user can select to streamline the CSV export.
The options are listed below: 
1.      Export feature types separately – Exports each feature type separately
2.      Export sub-level properties - allows for properties at the sub building level, i.e. storey or floorplate, to be exported to the CSV.
3.      Export object identifier column - exports the objects name and ID.
4.      Export URIs for property names and lists – it exports the uniform resource identifier for each of the attributes that is exported
5.      Export units with property names – Exports the units with the corresponding property names
6.      Export empty columns – Exports columns with no data in it
7.      Export Coordinates - includes the latitude and longitude of each object in the CSV
8.      Aggregate results - outputs the sum total of each results.
In this example, number of storeys for the selected buildings is edited to 4.
Figure 4-76 Building Attributes – Exported CSV file opened in MS Excel
Now that the desired attribute was modified, in the CSV file and then re-imported into the model using the import process described in the previous paragraph.
In the CSV import dialogue box, change number of storeys to existing attribute < match the Building ID with ID and follow the steps as explained in the previous paragraph (CSV import 4.9.14.1).
Figure 4-77 CSV Import Attribute Mapping dialogue box
The number of storeys for the selected have been updated based on the imported CSV details. The user can modify the attributes based on the model requirements and re-import the CSV file into the iCD model by following the same steps as explained earlier.
Figure 4-78 Imported CSV attributes in existing iCD model
 