The easiest way to generate 3D objects in iCD is to import them from Open Street Map (OSM).
Clicking on the OSM import icon in the toolbar opens the IMPORT FROM OPENSTREETMAP dialog. This dialog, consisting in a map with location search box and zoom controls can be used to find and set the area to be imported. The user can type the name of the desired location. The search tool provides a list of matched locations with matching pins on the map. Select the desired location from the list – a blue pin appears in the selected location. Left-click the blue pin (dialogue box pops up) and click “Place import site at this location” (yellow pin appears).
The import location can also be selected by right-clicking on the desired location directly on the map and by clicking on “Place Import Site”.
Select the new yellow pin to enter the radius of the site to be imported. Once done, click on “Save” to save the import radius.
Figure 4-1: OpenStreetMap Import dialog box
Import Options in the OSM dialogue box can be used to filter the imported objects from the selected location. The following is the brief description of the OSM import options:
Include Buildings – This option is used to import the buildings from the selected location. There are several options in Include Buildings which are as follows:
· With 3D Shell – Buildings as imported as 3D shell structures (no glazing details).
· As Adjacent Buildings – Buildings will be imported as adjacent buildings. Adjacent buildings are 3D shell structures containing the least information about the building details (only building height details). Adjacent buildings cannot be simulated.
· Estimate Building height and/or storeys – This option is used to import the buildings with the available building details from OSM resources (including the number of floors and building height).
· Default height – This option is used to import buildings with the default height based on the user’s preference. All the buildings that do not have height data embedded within OSM will be imported with this customised building height.
· Roofs – This option is used to import buildings with different roof types such as Flat, Hipped or Gabled Roofs.
Include Roads and Pavements –The roads and pavements details are available in the selected location will be imported.
Include Landscaping – This option is used to import all the Landscaping features (Hard Landscape, Soft Landscape and water bodies) in the selected location.
Include Terrain – This option is used to import the terrain ground texture/map tiles for the selected location.
Include map tiles (ground plane) – Map tiles are the basic ground texture details imported from the OSM.
Filtering – Filtering is an important feature to specifically deal with building imports from the selected location. The Filters option in OSM are as follows:
· Area – The buildings >= to the minimum area entered will be imported from the selected location.
· Height – The buildings with the minimum height (entered value) will be imported from the selected location.
· Area or Height – The buildings with either the specified height or with the specified area will be imported from the selected location.
· Area and Height - The buildings which satisfies both the conditions (Min Height and Min Area) will be imported from the selected location.
The objects from selected location with the specified import options will be imported as iCD file.